On the RF Heating of Coronary Stents at 7.0 Tesla MRI

被引:56
|
作者
Winter, Lukas [1 ]
Oberacker, Eva [1 ]
Oezerdem, Celal [1 ]
Ji, Yiyi [1 ]
von Knobelsdorff-Brenkenhoff, Florian [1 ,2 ,3 ]
Weidemann, Gerd [4 ,5 ]
Ittermann, Bernd [4 ,5 ]
Seifert, Frank [4 ,5 ]
Niendorf, Thoralf [1 ,2 ,3 ]
机构
[1] Max Delbrueck Ctr Mol Med, BUFF, D-13125 Berlin, Germany
[2] Charite Med Fac, ECRC, Berlin, Germany
[3] Max Delbrueck Ctr Mol Med, D-13125 Berlin, Germany
[4] PTB, Braunschweig, Germany
[5] PTB, Berlin, Germany
关键词
ultrahigh field MR; RF heating; coronary stents; specific absorption rate; RF power deposition; MAGNETIC-RESONANCE; ELECTRICAL-CONDUCTIVITY; PARALLEL TRANSMISSION; CARDIAC MRI; 7; T; COIL; COMPATIBILITY; MULTICENTER; IMPLANTS; DESIGN;
D O I
10.1002/mrm.25483
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Examine radiofrequency (RF) induced heating of coronary stents at 7.0 Tesla (T) to derive an analytical approach which supports RF heating assessment of arbitrary stent geometries and RF coils. Methods: Simulations are performed to detail electromagnetic fields (EMF), local specific absorption rates (SAR) and temperature changes. For validation E-field measurements and RF heating experiments are conducted. To progress to clinical setups RF coils tailored for cardiac MRI at 7.0T and coronary stents are incorporated into EMF simulations using a human voxel model. Results: Our simulations of coronary stents at 297 MHz were confirmed by E-field and temperature measurements. An analytical solution which describes SAR((1g tissue voxel)) induced by an arbitrary coronary stent interfering with E-fields generated by an arbitrary RF coil was derived. The analytical approach yielded a conservative estimation of induced SAR(1g tissue voxel) maxima without the need for integrating the stent into EMF simulations of the human voxel model. Conclusion: The proposed analytical approach can be applied for any patient, coronary stent type, RF coil configuration and RF transmission regime. The generalized approach is of value for RF heating assessment of other passive electrically conductive implants and provides a novel design criterion for RF coils. (C) 2014 Wiley Periodicals, Inc.
引用
收藏
页码:999 / 1010
页数:12
相关论文
共 50 条
  • [31] Dental MRI using a dedicated RF-coil at 3 Tesla
    Prager, Marcel
    Heiland, Sabine
    Gareis, Daniel
    Hilgenfeld, Tim
    Bendszus, Martin
    Gaudino, Chiara
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2015, 43 (10) : 2175 - 2182
  • [32] Cardiorenal 23Na MRI at 7.0 Tesla using a 4/4 channel 1H/23Na RF antenna array
    Boehmert, Laura
    Kuehne, Andre
    Waiczies, Helmar
    Wenz, Daniel
    Eigentler, Thomas Wilhelm
    Funk, Stephanie
    von Knobelsdorff-Brenkenhoff, Florian
    Schulz-Menger, Jeanette
    Nagel, Armin M.
    Seeliger, Erdmann
    Niendorf, Thoralf
    MAGNETIC RESONANCE IN MEDICINE, 2019, 82 (06) : 2343 - 2356
  • [33] Perforating arteries originating from the posterior communicating artery: a 7.0-Tesla MRI study
    Mandy M. A. Conijn
    Jeroen Hendrikse
    Jaco J. M. Zwanenburg
    Taro Takahara
    Mirjam I. Geerlings
    Willem P. Th. M. Mali
    Peter R. Luijten
    European Radiology, 2009, 19 : 2986 - 2992
  • [34] On the heating of inductively coupled resonators (stents) during MRI examinations
    Busch, M
    Vollmann, W
    Bertsch, T
    Wetzler, R
    Bornstedt, A
    Schnackenburg, B
    Schnorr, J
    Kivelitz, D
    Taupitz, M
    Grönemeyer, D
    MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (04) : 775 - 782
  • [35] Evaluation of MR angiography at 7.0 Tesla MRI using birdcage radio frequency coils with end caps
    Kang, Chang-Ki
    Hong, Suk-Min
    Han, Jae-Yong
    Kim, Kyoung-Narn
    Kim, Sang-Hoon
    Kim, Young-Bo
    Cho, Zang-Hee
    MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (02) : 330 - 338
  • [36] Is MRI a safe procedure in patients with coronary stents in situ?
    Kotsakis, A
    Tan, KH
    Jackson, G
    INTERNATIONAL JOURNAL OF CLINICAL PRACTICE, 1997, 51 (06) : 349 - 349
  • [37] The TESLA RF system
    Choroba, S
    HIGH ENERGY DENSITY AND HIGH POWER RF, 2003, 691 : 1 - 14
  • [38] RF Heating of MRI-Assisted Catheter Steering Coils for Interventional MRI
    Settecase, Fabio
    Hetts, Steven W.
    Martin, Alastair J.
    Roberts, Timothy P. L.
    Bernhardt, Anthony F.
    Evans, Lee
    Malba, Vincent
    Saeed, Maythem
    Arenson, Ronald L.
    Kucharzyk, Walter
    Wilson, Mark W.
    ACADEMIC RADIOLOGY, 2011, 18 (03) : 277 - 285
  • [39] Distribution and natural course of intracranial vessel wall lesions in patients with ischemic stroke or TIA at 7.0 tesla MRI
    van der Kolk, Anja G.
    Zwanenburg, Jaco J. M.
    Brundel, Manon
    Biessels, Geert Jan
    Visser, Fredy
    Luijten, Peter R.
    Hendrikse, Jeroen
    EUROPEAN RADIOLOGY, 2015, 25 (06) : 1692 - 1700
  • [40] The shape, size, and asymmetry of fetal hippocampal formation during the second trimester: A 7.0 Tesla postmortem MRI study
    Liu, Shuwei
    Liu, Jun
    Zhang, Zhonghe
    Teng, Gaojun
    Fang, Fang
    Zang, Fengcao
    FASEB JOURNAL, 2012, 26