A Study on the Effect of Contact Pressure during Physical Activity on Photoplethysmographic Heart Rate Measurements

被引:37
|
作者
Scardulla, Francesco [1 ]
D'Acquisto, Leonardo [1 ]
Colombarini, Raffaele [1 ]
Hu, Sijung [2 ]
Pasta, Salvatore [1 ]
Bellavia, Diego [3 ]
机构
[1] Univ Palermo, Dept Engn, I-90128 Palermo, Italy
[2] Loughborough Univ, Wolfson Sch Mech Elect & Mfg Engn, Loughborough LE11 3TU, Leics, England
[3] IRCCS, ISMETT, Dept Treatment & Study Cardiothorac Dis & Cardiot, Via Tricomi 5, I-90127 Palermo, Italy
关键词
photoplethysmography (PPG); PPG sensor; wearables; contact pressure; contact force; heart rate (HR); heart rate signal; PPG accuracy; heart rate reliability; MOTION ARTIFACT; SENSOR; MONITOR; FORCE;
D O I
10.3390/s20185052
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Heart rate (HR) as an important physiological indicator could properly describe global subject's physical status. Photoplethysmographic (PPG) sensors are catching on in field of wearable sensors, combining the advantages in costs, weight and size. Nevertheless, accuracy in HR readings is unreliable specifically during physical activity. Among several identified sources that affect PPG recording, contact pressure (CP) between the PPG sensor and skin greatly influences the signals. Methods: In this study, the accuracy of HR measurements of a PPG sensor at different CP was investigated when compared with a commercial ECG-based chest strap used as a test control, with the aim of determining the optimal CP to produce a reliable signal during physical activity. Seventeen subjects were enrolled for the study to perform a physical activity at three different rates repeated at three different contact pressures of the PPG-based wristband. Results: The results show that the CP of 54 mmHg provides the most accurate outcome with a Pearson correlation coefficient ranging from 0.81 to 0.95 and a mean average percentage error ranging from 3.8% to 2.4%, based on the physical activity rate. Conclusion: Authors found that changes in the CP have greater effects on PPG-HR signal quality than those deriving from the intensity of the physical activity and specifically, the individual best CP for each subject provided reliable HR measurements even for a high intensity of physical exercise with a Bland-Altman plot within +/- 11 bpm. Although future studies on a larger cohort of subjects are still needed, this study could contribute a profitable indication to enhance accuracy of PPG-based wearable devices.
引用
收藏
页码:1 / 15
页数:15
相关论文
共 50 条
  • [41] CHANGES IN PLASMA NOREPINEPHRINE, BLOOD-PRESSURE AND HEART-RATE DURING PHYSICAL-ACTIVITY IN HYPERTENSIVE MAN
    WATSON, RDS
    HAMILTON, CA
    REID, JL
    LITTLER, WA
    HYPERTENSION, 1979, 1 (04) : 341 - 346
  • [42] The relationship of electronically monitored physical activity to blood pressure, heart rate, and the circadian blood pressure profile
    Mansoor, GA
    White, WB
    McCabe, EJ
    Giacco, S
    AMERICAN JOURNAL OF HYPERTENSION, 2000, 13 (03) : 262 - 267
  • [43] Temporal stability of ambulatory heart rate and blood pressure measurements and their dependence on types of activity
    Hinz, A
    Schmutzer, G
    Schreinicke, G
    Huber, B
    JOURNAL OF PSYCHOPHYSIOLOGY, 1998, 12 (02) : 197 - 197
  • [44] Physical activity, resting heart rate, and atrial fibrillation: the Tromso Study
    Morseth, Bente
    Graff-Iversen, Sidsel
    Jacobsen, Bjarne K.
    Jorgensen, Lone
    Nyrnes, Audhild
    Thelle, Dag S.
    Vestergaard, Peter
    Lochen, Maja-Lisa
    EUROPEAN HEART JOURNAL, 2016, 37 (29) : 2307 - 2313
  • [45] Robust heart rate estimation using wrist-type photoplethysmographic signals during physical exercise: an approach based on adaptive filtering
    Fallet, Sibylle
    Vesin, Jean-Marc
    PHYSIOLOGICAL MEASUREMENT, 2017, 38 (02) : 155 - 170
  • [46] HEART-RATE AND PHYSICAL-ACTIVITY OF CHILDREN DURING DENTAL TREATMENT
    ROSENBERG, HM
    KATCHER, AH
    JOURNAL OF DENTAL RESEARCH, 1976, 55 (04) : 648 - 651
  • [47] Heart rate variability series during physical activity analyzed with multifractal techniques
    Aguilar-Molina, Ana Maria
    Zamora-Justo, Jose Alberto
    Angulo-Brown, Fernando
    Munoz-Diosdado, Alejandro
    JOURNAL OF PHYSICS-COMPLEXITY, 2024, 5 (04):
  • [48] Integrated Wearable System for Monitoring Heart Rate and Step during Physical Activity
    Prawiro, Eka Adi Prasetyo Joko
    Yeh, Chun-I
    Chou, Nai-Kuan
    Lee, Ming-Wei
    Lin, Yuan-Hsiang
    MOBILE INFORMATION SYSTEMS, 2016, 2016
  • [49] HEART-RATE AND PHYSICAL-ACTIVITY DURING DENTAL PROCEDURES IN CHILDREN
    ROSENBERG, H
    KATCHER, A
    JOURNAL OF DENTAL RESEARCH, 1975, 54 : 167 - 167
  • [50] HEART RATE BEHAVIOR IN YOUNG ADULTS DURING PHYSICAL EXERCISE AND SEXUAL ACTIVITY
    de Souza, Cicero Augusto
    Cardoso, Fernando Luiz
    Silveira, Rozana Aparecida
    Wittkopf, Priscilla Geraldine
    REVISTA BRASILEIRA DE MEDICINA DO ESPORTE, 2012, 18 (05) : 345 - 346