A Study on the Effect of Contact Pressure during Physical Activity on Photoplethysmographic Heart Rate Measurements

被引:37
|
作者
Scardulla, Francesco [1 ]
D'Acquisto, Leonardo [1 ]
Colombarini, Raffaele [1 ]
Hu, Sijung [2 ]
Pasta, Salvatore [1 ]
Bellavia, Diego [3 ]
机构
[1] Univ Palermo, Dept Engn, I-90128 Palermo, Italy
[2] Loughborough Univ, Wolfson Sch Mech Elect & Mfg Engn, Loughborough LE11 3TU, Leics, England
[3] IRCCS, ISMETT, Dept Treatment & Study Cardiothorac Dis & Cardiot, Via Tricomi 5, I-90127 Palermo, Italy
关键词
photoplethysmography (PPG); PPG sensor; wearables; contact pressure; contact force; heart rate (HR); heart rate signal; PPG accuracy; heart rate reliability; MOTION ARTIFACT; SENSOR; MONITOR; FORCE;
D O I
10.3390/s20185052
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Heart rate (HR) as an important physiological indicator could properly describe global subject's physical status. Photoplethysmographic (PPG) sensors are catching on in field of wearable sensors, combining the advantages in costs, weight and size. Nevertheless, accuracy in HR readings is unreliable specifically during physical activity. Among several identified sources that affect PPG recording, contact pressure (CP) between the PPG sensor and skin greatly influences the signals. Methods: In this study, the accuracy of HR measurements of a PPG sensor at different CP was investigated when compared with a commercial ECG-based chest strap used as a test control, with the aim of determining the optimal CP to produce a reliable signal during physical activity. Seventeen subjects were enrolled for the study to perform a physical activity at three different rates repeated at three different contact pressures of the PPG-based wristband. Results: The results show that the CP of 54 mmHg provides the most accurate outcome with a Pearson correlation coefficient ranging from 0.81 to 0.95 and a mean average percentage error ranging from 3.8% to 2.4%, based on the physical activity rate. Conclusion: Authors found that changes in the CP have greater effects on PPG-HR signal quality than those deriving from the intensity of the physical activity and specifically, the individual best CP for each subject provided reliable HR measurements even for a high intensity of physical exercise with a Bland-Altman plot within +/- 11 bpm. Although future studies on a larger cohort of subjects are still needed, this study could contribute a profitable indication to enhance accuracy of PPG-based wearable devices.
引用
收藏
页码:1 / 15
页数:15
相关论文
共 50 条
  • [21] Heart Rate and Blood Pressure as Measures of Physical Condition During Adolescence
    Pennock, Erastus W.
    RESEARCH QUARTERLY, 1935, 6 (02): : 120 - 125
  • [22] A Robust Dynamic Heart-Rate Detection Algorithm Framework During Intense Physical Activities Using Photoplethysmographic Signals
    Song, Jiajia
    Li, Dan
    Ma, Xiaoyuan
    Teng, Guowei
    Wei, Jianming
    SENSORS, 2017, 17 (11):
  • [23] An Efficient Method for Heart Rate Monitoring Using Wrist-Type Photoplethysmographic Signals During Intensive Physical Exercise
    Ahamed, Sk. Tanvir
    Islam, Mohammad Tariqul
    2016 5TH INTERNATIONAL CONFERENCE ON INFORMATICS, ELECTRONICS AND VISION (ICIEV), 2016, : 863 - 868
  • [24] Heart Rate Tracking using Wrist-Type Photoplethysmographic (PPG) Signals during Physical Exercise with Simultaneous Accelerometry
    Mashhadi, Mahdi Boloursaz
    Asadi, Ehsan
    Eskandari, Mohsen
    Kiani, Shahrzad
    Marvasti, Farokh
    IEEE SIGNAL PROCESSING LETTERS, 2016, 23 (02) : 227 - 231
  • [25] Validity of heart-rate based measurements of oxygen consumption during work with light and moderate physical activity
    Bernmark, Eva
    Forsman, Mikael
    Pernold, Gunilla
    Wiktorin, Christina
    WORK-A JOURNAL OF PREVENTION ASSESSMENT & REHABILITATION, 2012, 41 : 5475 - 5476
  • [26] Non-contact heart rate and heart rate variability measurements: A review
    Kranjec, J.
    Begus, S.
    Gersak, G.
    Drnovsek, J.
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2014, 13 : 102 - 112
  • [27] Heuristic Algorithm for Photoplethysmographic Heart Rate Tracking During Maximal Exercise Test
    Maria Lopez-Silva, Sonnia
    Giannetti, Romano
    Luisa Dotor, Maria
    Pedro Silveira, Juan
    Golmayo, Dolores
    Miguel-Tobal, Francisco
    Bilbao, Amaya
    Galindo, Mercedes
    Martin-Escudero, Pilar
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2012, 32 (03) : 181 - 188
  • [28] Heart Rate Tracking Using a Wearable Photoplethysmographic Sensor During Treadmill Exercise
    Kong, Youngsun
    Chon, Ki H.
    IEEE ACCESS, 2019, 7 : 152421 - 152428
  • [29] Subtle physical activity poses a challenge to the study of heart rate
    Major, P
    PHYSIOLOGY & BEHAVIOR, 1998, 63 (03) : 381 - 384
  • [30] Biological and psychological predictors of heart rate patterns during physical activity
    Kaplan, Deanna M.
    Palitsky, Roman
    Dunsiger, Shira I.
    Wu, Wen-Chih
    Parker, Amira G.
    Troubh, Jessica K.
    Whitworth, James. W.
    Bock, Beth C.
    PSYCHOLOGY OF SPORT AND EXERCISE, 2023, 65