A Study on the Effect of Contact Pressure during Physical Activity on Photoplethysmographic Heart Rate Measurements

被引:37
|
作者
Scardulla, Francesco [1 ]
D'Acquisto, Leonardo [1 ]
Colombarini, Raffaele [1 ]
Hu, Sijung [2 ]
Pasta, Salvatore [1 ]
Bellavia, Diego [3 ]
机构
[1] Univ Palermo, Dept Engn, I-90128 Palermo, Italy
[2] Loughborough Univ, Wolfson Sch Mech Elect & Mfg Engn, Loughborough LE11 3TU, Leics, England
[3] IRCCS, ISMETT, Dept Treatment & Study Cardiothorac Dis & Cardiot, Via Tricomi 5, I-90127 Palermo, Italy
关键词
photoplethysmography (PPG); PPG sensor; wearables; contact pressure; contact force; heart rate (HR); heart rate signal; PPG accuracy; heart rate reliability; MOTION ARTIFACT; SENSOR; MONITOR; FORCE;
D O I
10.3390/s20185052
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Heart rate (HR) as an important physiological indicator could properly describe global subject's physical status. Photoplethysmographic (PPG) sensors are catching on in field of wearable sensors, combining the advantages in costs, weight and size. Nevertheless, accuracy in HR readings is unreliable specifically during physical activity. Among several identified sources that affect PPG recording, contact pressure (CP) between the PPG sensor and skin greatly influences the signals. Methods: In this study, the accuracy of HR measurements of a PPG sensor at different CP was investigated when compared with a commercial ECG-based chest strap used as a test control, with the aim of determining the optimal CP to produce a reliable signal during physical activity. Seventeen subjects were enrolled for the study to perform a physical activity at three different rates repeated at three different contact pressures of the PPG-based wristband. Results: The results show that the CP of 54 mmHg provides the most accurate outcome with a Pearson correlation coefficient ranging from 0.81 to 0.95 and a mean average percentage error ranging from 3.8% to 2.4%, based on the physical activity rate. Conclusion: Authors found that changes in the CP have greater effects on PPG-HR signal quality than those deriving from the intensity of the physical activity and specifically, the individual best CP for each subject provided reliable HR measurements even for a high intensity of physical exercise with a Bland-Altman plot within +/- 11 bpm. Although future studies on a larger cohort of subjects are still needed, this study could contribute a profitable indication to enhance accuracy of PPG-based wearable devices.
引用
收藏
页码:1 / 15
页数:15
相关论文
共 50 条
  • [1] Robust Heart Rate Estimation During Physical Exercise Using Photoplethysmographic Signals
    Motin, Mohammod Abdul
    Karmakar, Chandan Kumar
    Palaniswami, Marimuthu
    2018 40TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2018, : 494 - 497
  • [2] EFFECT OF ACTIVITY DURING BEDMAKING ON HEART RATE AND BLOOD PRESSURE
    PALMER, EM
    GRIFFITH, EW
    NURSING RESEARCH, 1971, 20 (01) : 17 - 25
  • [3] Unobtrusive Heart Rate Estimation during Physical Exercise using Photoplethysmographic and Acceleration Data
    Mullan, Patrick
    Kanzler, Christoph M.
    Lorch, Benedikt
    Schroeder, Lea
    Winkler, Ludwig
    Laich, Larissa
    Riedel, Frederik
    Richer, Robert
    Luckner, Christoph
    Leutheuser, Heike
    Eskofier, Bjoern M.
    Pasluosta, Cristian
    2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 6114 - 6117
  • [4] A NEW METHOD FOR HEART RATE MONITORING DURING PHYSICAL EXERCISE USING PHOTOPLETHYSMOGRAPHIC SIGNALS
    Schaeck, Tim
    Sledz, Christian
    Muma, Michael
    Zoubir, Abdelhak M.
    2015 23RD EUROPEAN SIGNAL PROCESSING CONFERENCE (EUSIPCO), 2015, : 2666 - 2670
  • [5] Computationally Efficient Heart Rate Estimation During Physical Exercise Using Photoplethysmographic Signals
    Schaeck, Tim
    Muma, Michael
    Zoubir, Abdelhak M.
    2017 25TH EUROPEAN SIGNAL PROCESSING CONFERENCE (EUSIPCO), 2017, : 2478 - 2481
  • [6] The Effect of Demanding Mental Tasks on Electrodermal Activity and Heart Rate During Physical Activity: A Pilot Study
    Castro-Garcia, Juan A.
    Molina-Cantero, Alberto J.
    Merino-Monge, Manuel
    Lebrato-Vazquez, Clara
    Gomez-Gonzalez, Isabel M.
    IEEE ACCESS, 2023, 11 : 46665 - 46677
  • [7] Estimating Heart Rate, Energy Expenditure, and Physical Performance With a Wrist Photoplethysmographic Device During Running
    Parak, Jakub
    Uuskoski, Maria
    Machek, Jan
    Korhonen, Ilkka
    JMIR MHEALTH AND UHEALTH, 2017, 5 (07):
  • [8] The Aggravating Effect of Frailty on Heart Rate Dynamics during Physical Activity in Patients with Heart Disease
    Ackun, P. E.
    Arrue, P.
    Toosizadeh, N.
    JOURNAL OF THE AMERICAN GERIATRICS SOCIETY, 2023, 71 : S138 - S138
  • [9] Heart Rate Monitoring During Physical Exercise Using Wrist-Type Photoplethysmographic (PPG) Signals
    Ahmadi, Amirhosein Khas
    Moradi, Parsa
    Malihi, Mahan
    Karimi, Sajjad
    Shamsollahi, Mohammad B.
    2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 6166 - 6169
  • [10] Ultra-Low Power Estimation of Heart Rate Under Physical Activity Using a Wearable Photoplethysmographic System
    De Giovanni, Elisabetta
    Atienza, David
    Murali, Srinivasan
    Rincon, Francisco
    19TH EUROMICRO CONFERENCE ON DIGITAL SYSTEM DESIGN (DSD 2016), 2016, : 553 - 560