Effects of size and insertion angle of orthodontic mini-implants on skeletal anchorage

被引:20
|
作者
Tatli, Ufuk [1 ]
Alraawi, Mohammed [2 ]
Toroglu, Mustafa Serdar [2 ]
机构
[1] Cukurova Univ, Sch Dent, Dept Oral & Maxillofacial Surg, TR-01330 Adana, Turkey
[2] Cukurova Univ, Sch Dent, Dept Orthodont, Adana, Turkey
关键词
BEAM COMPUTED-TOMOGRAPHY; CORTICAL BONE THICKNESS; PRIMARY STABILITY; QUANTITATIVE-EVALUATION; RESONANCE FREQUENCY; PLACEMENT TORQUE; SUCCESS RATE; IN-VITRO; MAXILLARY; MINISCREWS;
D O I
10.1016/j.ajodo.2018.08.026
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The primary aim of this in vitro study was to compare the insertion torque (IT) and anchorage force (AF) values of 4 different sizes of orthodontic mini-implants with 2 different angles. The second aim was to evaluate the relationship between IT and AF values under different diameter, length, and insertion angle variables. Methods: A total of 160 mini-implants, including 20 implants in each group, with 4 different sizes (1.6 x 8 mm, 1.6 x 10 mm, 2.0 x 8 mm, and 2.0 x 10 mm) at 2 different angles (70 degrees and 90 degrees), were inserted into bovine iliac bone segments. The IT and AF values leading to 1.5 mm deflection were compared. The correlations between IT and AF values under different variables were also analyzed. Result: The mini-implants with greater diameter and length showed greater IT and AF values (P <0.05). The IT and AF values of mini-implants inserted at 70 degrees angle were significantly greater than those of mini-implants inserted at 90 degrees angle (P <0.001). Significant correlations were found between IT and AF values in all variables. Conclusion: The diameter, length, and insertion angle of orthodontic mini-implants have significant effects on IT and AF values. Insertion angle and diameter of mini-implants are more effective than implant length on skeletal anchorage. Significant correlations are present between IT and AF values of mini-implants regardless of their diameters, lengths, and insertion angles.
引用
收藏
页码:220 / 228
页数:9
相关论文
共 50 条
  • [41] Mass retraction movement of the anterior upper teeth using orthodontic mini-implants as anchorage
    Leonardo Henrique de Lima Araújo
    Elton Gonçalves Zenóbio
    Wellington Pacheco
    Maurício Greco Cosso
    Flávio Ricardo Manzi
    Jamil Awad Shibli
    Oral and Maxillofacial Surgery, 2012, 16 (1) : 95 - 99
  • [42] A prospective study of the risk factors associated with failure of mini-implants used for orthodontic anchorage
    Cheng, SJ
    Tseng, IY
    Lee, JJ
    Kok, SH
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2004, 19 (01) : 100 - 106
  • [43] Insertion torque and orthodontic mini-implants: A systematic review of the artificial bone literature
    Reynders, Reint Meursinge
    Ronchi, Laura
    Ladu, Luisa
    Van Etten-Jamaludin, Faridi
    Bipat, Shandra
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2013, 227 (11) : 1181 - 1202
  • [44] Geometrical design characteristics of orthodontic mini-implants predicting maximum insertion torque
    Katic, Visnja
    Kamenar, Ervin
    Blazevic, David
    S'palj, Stjepan
    KOREAN JOURNAL OF ORTHODONTICS, 2014, 44 (04) : 177 - 183
  • [45] Impact of Insertion Depth and Predrilling Diameter on Primary Stability of Orthodontic Mini-implants
    Wilmes, Benedict
    Drescher, Dieter
    ANGLE ORTHODONTIST, 2009, 79 (04) : 609 - 614
  • [46] Evaluation of Palatal Bone Thickness for Insertion of Orthodontic Mini-Implants in Adults and Adolescents
    Wang, Manying
    Sun, Yang
    Yu, Yuncheng
    Ding, Xiaojun
    JOURNAL OF CRANIOFACIAL SURGERY, 2017, 28 (06) : 1468 - 1471
  • [47] Correction of a mutilated dentition with mini-implants as anchorage
    Hyun, Jae-Man
    Kim, Tae-Woo
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2010, 138 (05) : 656 - 665
  • [48] Microcomputed Tomographic Analysis of Bone Reaction at Insertion of Orthodontic Mini-implants in Sheep
    Rebaudi, Alberto
    Laffi, Nicola
    Benedicenti, Stefano
    Angiero, Francesca
    Romanos, George E.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2011, 26 (06) : 1233 - 1240
  • [49] Relationship between vertical skeletal pattern and success rate of orthodontic mini-implants
    Moon, Cheol-Hyun
    Park, Hyun-Kyung
    Nam, Ji-Seon
    Im, Jeong-Soo
    Baek, Seung-Hak
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2010, 138 (01) : 51 - 57
  • [50] Palatal median Insertion of Mini-Implants
    Nienkemper, Manus
    Pauls, Alexander
    Wilmes, Benedict
    Drescher, Dieter
    INFORMATIONEN AUS ORTHODONTIE UND KIEFERORTHOPAEDIE, 2019, 51 (01): : 8 - 10