Insertion torque and orthodontic mini-implants: A systematic review of the artificial bone literature

被引:12
|
作者
Reynders, Reint Meursinge
Ronchi, Laura
Ladu, Luisa
Van Etten-Jamaludin, Faridi [1 ]
Bipat, Shandra [2 ,3 ,4 ]
机构
[1] Univ Amsterdam, Acad Med Ctr, Med Lib, NL-1105 AZ Amsterdam, Netherlands
[2] Univ Amsterdam, Acad Med Ctr, Dept Radiol, NL-1105 AZ Amsterdam, Netherlands
[3] Univ Amsterdam, Acad Med Ctr, Dept Epidemiol, NL-1105 AZ Amsterdam, Netherlands
[4] Univ Amsterdam, Acad Med Ctr, Dept Biostat, NL-1105 AZ Amsterdam, Netherlands
关键词
Systematic review; insertion torque; orthodontics; mini-implant; artificial bone; publication bias; risk of bias; standardized test; PRIMARY STABILITY; CORTICAL-BONE; MECHANICAL STABILITY; REMOVAL TORQUE; IN-VITRO; SURGICAL TECHNIQUE; SURFACE-ROUGHNESS; PLACEMENT TORQUE; SYNTHETIC FOAM; IMPACT;
D O I
10.1177/0954411913495986
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This article systematically reviewed the literature to (1) identify variables that were associated with maximum insertion torque values during the insertion of orthodontic mini-implants into artificial bone, (2) quantify such associations and (3) assess adverse effects of this procedure. Computerized and manual searches were conducted up to 24 February 2012. Selection criteria included studies that (1) recorded maximum insertion torque during the insertion of orthodontic mini-implants into artificial bone, (2) used sample sizes of five screws or more, (3) assessed maximum insertion torque with electronic torque sensors, and (4) used orthodontic mini-implants with a diameter smaller than 2.5 mm. ASTM Standards F543-07(epsilon 1) and F1839-08(epsilon 1) and the Cochrane Handbook for Systematic Reviews were used as guidelines for this systematic review. Quality assessments were rated according to the Grading of Recommendations, Assessment, Development and Evaluation (GRADE) approach. A total of 23 studies were selected, many of which were multiple publications of the same study. Many domains in the risk of bias assessments were scored as high or unclear risk of bias. A wide variety of implant, test block, and insertion procedure-related associations with maximum insertion torque were recorded. The quality of most outcomes was classified as moderate. Outcomes could not be combined in a meta-analysis because of high risk of bias, poor standardization, high heterogeneity, or inconsistency in direction of outcomes within or between studies. Adverse effects were only assessed in one study. Future studies should control publication bias, consult existing standards for conducting torque tests, and focus on transparent reporting.
引用
收藏
页码:1181 / 1202
页数:22
相关论文
共 50 条
  • [1] Insertion torque and success of orthodontic mini-implants: A systematic review
    Reynders, Reint A. Meursinge
    Ronchi, Laura
    Ladu, Luisa
    van Etten-Jamaludin, Faridi
    Bipat, Shandra
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2012, 142 (05) : 596 - +
  • [2] Insertion torque recordings for the diagnosis of contact between orthodontic mini-implants and dental roots: A systematic review
    Meursinge Reynders R.
    Ladu L.
    Ronchi L.
    Di Girolamo N.
    de Lange J.
    Roberts N.
    Plüddemann A.
    Systematic Reviews, 5 (1)
  • [3] Insertion torque values and success rates for paramedian insertion of orthodontic mini-implants
    Di Leonardo, Bruno
    Ludwig, Bjoern
    Lisson, Joerg Alexander
    Contardo, Luca
    Mura, Rossano
    Hourfar, Jan
    JOURNAL OF OROFACIAL ORTHOPEDICS-FORTSCHRITTE DER KIEFERORTHOPADIE, 2018, 79 (02): : 109 - 115
  • [4] Insertion torque recordings for the diagnosis of contact between orthodontic mini-implants and dental roots: Protocol for a systematic review
    Meursinge Reynders R.
    Ladu L.
    Ronchi L.
    Di Girolamo N.
    de Lange J.
    Roberts N.
    Plüddemann A.
    Systematic Reviews, 4 (1)
  • [5] Geometrical design characteristics of orthodontic mini-implants predicting maximum insertion torque
    Katic, Visnja
    Kamenar, Ervin
    Blazevic, David
    S'palj, Stjepan
    KOREAN JOURNAL OF ORTHODONTICS, 2014, 44 (04) : 177 - 183
  • [6] Mini-implants in orthodontics: A systematic review of the literature
    Reynders, Reint
    Ronchi, Laura
    Bipat, Shandra
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2009, 135 (05) : 564 - 565
  • [7] Critical factors for the success of orthodontic mini-implants: A systematic review
    Chen, Yan
    Kyung, Hee Moon
    Zhao, Wen Ting
    Yu, Won Jae
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2009, 135 (03) : 284 - 291
  • [8] Effect of cutting flute length and shape on insertion and removal torque of orthodontic mini-implants
    Yun, Soon-dong
    Lim, Sung-hoon
    KOREAN JOURNAL OF ORTHODONTICS, 2009, 39 (02) : 95 - 104
  • [9] Design of orthodontic mini-implants contributing to implantation torque
    Katic, V.
    Spalj, S.
    Opalic, M.
    Domitran, Z.
    BIODENTAL ENGINEERING II, 2014, : 29 - 33
  • [10] Dimensions Define Stability: Insertion Torque of Orthodontic Mini-Implants: A Comparative In Vitro Study
    Romanec, Cristian Liviu
    Panaite, Tinela
    Zetu, Irina Nicoleta
    JOURNAL OF CLINICAL MEDICINE, 2025, 14 (05)