Insertion torque and orthodontic mini-implants: A systematic review of the artificial bone literature

被引:12
|
作者
Reynders, Reint Meursinge
Ronchi, Laura
Ladu, Luisa
Van Etten-Jamaludin, Faridi [1 ]
Bipat, Shandra [2 ,3 ,4 ]
机构
[1] Univ Amsterdam, Acad Med Ctr, Med Lib, NL-1105 AZ Amsterdam, Netherlands
[2] Univ Amsterdam, Acad Med Ctr, Dept Radiol, NL-1105 AZ Amsterdam, Netherlands
[3] Univ Amsterdam, Acad Med Ctr, Dept Epidemiol, NL-1105 AZ Amsterdam, Netherlands
[4] Univ Amsterdam, Acad Med Ctr, Dept Biostat, NL-1105 AZ Amsterdam, Netherlands
关键词
Systematic review; insertion torque; orthodontics; mini-implant; artificial bone; publication bias; risk of bias; standardized test; PRIMARY STABILITY; CORTICAL-BONE; MECHANICAL STABILITY; REMOVAL TORQUE; IN-VITRO; SURGICAL TECHNIQUE; SURFACE-ROUGHNESS; PLACEMENT TORQUE; SYNTHETIC FOAM; IMPACT;
D O I
10.1177/0954411913495986
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This article systematically reviewed the literature to (1) identify variables that were associated with maximum insertion torque values during the insertion of orthodontic mini-implants into artificial bone, (2) quantify such associations and (3) assess adverse effects of this procedure. Computerized and manual searches were conducted up to 24 February 2012. Selection criteria included studies that (1) recorded maximum insertion torque during the insertion of orthodontic mini-implants into artificial bone, (2) used sample sizes of five screws or more, (3) assessed maximum insertion torque with electronic torque sensors, and (4) used orthodontic mini-implants with a diameter smaller than 2.5 mm. ASTM Standards F543-07(epsilon 1) and F1839-08(epsilon 1) and the Cochrane Handbook for Systematic Reviews were used as guidelines for this systematic review. Quality assessments were rated according to the Grading of Recommendations, Assessment, Development and Evaluation (GRADE) approach. A total of 23 studies were selected, many of which were multiple publications of the same study. Many domains in the risk of bias assessments were scored as high or unclear risk of bias. A wide variety of implant, test block, and insertion procedure-related associations with maximum insertion torque were recorded. The quality of most outcomes was classified as moderate. Outcomes could not be combined in a meta-analysis because of high risk of bias, poor standardization, high heterogeneity, or inconsistency in direction of outcomes within or between studies. Adverse effects were only assessed in one study. Future studies should control publication bias, consult existing standards for conducting torque tests, and focus on transparent reporting.
引用
收藏
页码:1181 / 1202
页数:22
相关论文
共 50 条
  • [31] Clinical analysis of successful insertion of orthodontic mini-implants in infrazygomatic crest
    Yinxue He
    Jinan Liu
    Rui Huang
    Xing Chen
    Xueting Jia
    Na Zeng
    Xiaochuan Fan
    Xiaofeng Huang
    BMC Oral Health, 23
  • [32] Root repair after contact with mini-implants: systematic review of the literature
    Alves, Matheus, Jr.
    Baratieri, Carolina
    Mattos, Claudia Trindade
    de Souza Araujo, Monica Tirre
    Maia, Lucianne Cople
    EUROPEAN JOURNAL OF ORTHODONTICS, 2013, 35 (04) : 491 - 499
  • [33] Comparing the Primary Stability of Three Different Orthodontic Mini-Implants with Various Dimensions on Artificial Bone
    Mohammed, Haneen I.
    Al-Sheakli, Iman I.
    INTERNATIONAL JOURNAL OF MEDICAL RESEARCH & HEALTH SCIENCES, 2018, 7 (01): : 128 - 134
  • [34] The application of mini-implants for orthodontic anchorage
    Tseng, Y. -C.
    Hsieh, C. -H.
    Chen, C. -H.
    Shen, Y. -S.
    Huang, I. -Y.
    Chen, C. -M.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2006, 35 (08) : 704 - 707
  • [35] Application of orthodontic mini-implants in adolescents
    Motoyoshi, M.
    Matsuoka, M.
    Shimizu, N.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2007, 36 (08) : 695 - 699
  • [36] Survival analysis of orthodontic mini-implants
    Lee, Shin-Jae
    Ahn, Sug-Joon
    Lee, Jae Won
    Kim, Seong-Hun
    Kim, Tae-Woo
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2010, 137 (02) : 194 - 199
  • [37] Mechanical anisotropy of orthodontic mini-implants
    Motoyoshi, M.
    Inaba, M.
    Ueno, S.
    Shimizu, N.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2009, 38 (09) : 972 - 977
  • [38] Stress distribution in orthodontic mini-implants
    Dobranszki, A.
    Levy Neto, F.
    Dobranszki, N. C.
    Vuolo, J. H.
    Laboissiere Jr, M. A.
    MATERIA-RIO DE JANEIRO, 2010, 15 (03): : 405 - 412
  • [39] Convenient removal of orthodontic mini-implants
    Kim, Hyewon
    Kim, Tae Kyung
    Lee, Shin-Jae
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2007, 131 (04) : S90 - S91
  • [40] Risk factors for orthodontic mini-implants in skeletal anchorage biological stability: a systematic literature review and meta-analysis
    María Dolores Casaña-Ruiz
    Carlos Bellot-Arcís
    Vanessa Paredes-Gallardo
    Verónica García-Sanz
    José Manuel Almerich-Silla
    José María Montiel-Company
    Scientific Reports, 10