Dry contact electrodes performance in canine ECG

被引:2
|
作者
Virtanen, Juhani [1 ,2 ]
Leivo, Joni [1 ,2 ]
Vehkaoja, Antti [1 ,2 ]
Somppi, Sanni [3 ]
Tornqvist, Heini [3 ]
Fiedler, Patrique [4 ]
Vaataja, Heli [5 ]
Surakka, Veikko [5 ]
机构
[1] Univ Tampere, BioMediTech Inst, Tampere, Finland
[2] Univ Tampere, Fac Biomed Sci & Engn, Tampere, Finland
[3] Univ Helsinki, Dept Equine & Small Anim Med, Helsinki, Finland
[4] Tech Univ Ilmenau, Inst Biomed Engn & Informat, Ilmenau, Germany
[5] Univ Tampere UTA, Res Grp Emot Social & Comp, Fac Commun Sci, Tampere, Finland
关键词
Canine; Electrocardiogram; Dry Electrode; HEART-RATE-VARIABILITY;
D O I
10.1145/3295598.3295609
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Measuring the heart rate of animals is an important area of research which can be applied to numerous analyses. In this work we evaluate the performance of two dry contact electrocardiogram (ECG) electrode structures for monitoring the heart rate of domestic pets. The aim was to improve the operation of previously evaluated electrodes with some modifications. First, the thirty-pins of a previously studied polymer electrode with a silver/silver chloride (Ag/AgCl) coating were reduced to 12. Second, a 12-pin gold-plated metal electrode was coated with poly (3,4 ethylenedioxythiophene) polystyrene sulfonate (PEDOT: PSS). These electrodes were attached to a specifically designed measurement harness and the performance of the electrodes was evaluated in terms of heartbeat detection coverage. The heart rate coverage was measured during four different behaviors: standing, sitting, lying, and walking (N=27/activity). The results were, in general, comparable to the previously reported performance but having fewer pins on a polymer electrode seemed to cause more variation in the coverage values. However, when measures such as the median value of the coverages are considered, there was no obvious difference, especially when the coverage values were observed altogether. Thus, new electrode solutions are worthy of further research.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] A low-power portable ECG sensor interface with dry electrodes
    浦小飞
    万磊
    张辉
    秦亚杰
    洪志良
    Journal of Semiconductors, 2013, 34 (05) : 104 - 109
  • [22] Characterization of Single Lead Continuous ECG Recording with Various Dry Electrodes
    ul Hassan, Muhammad Faiz
    Lai, Dakun
    Bu, Yuxiang
    ICCBB 2019: PROCEEDINGS OF THE 2019 3RD INTERNATIONAL CONFERENCE ON COMPUTATIONAL BIOLOGY AND BIOINFORMATICS, 2019, : 76 - 79
  • [23] A low-power portable ECG sensor interface with dry electrodes
    Pu Xiaofei
    Wan Lei
    Zhang Hui
    Qin Yajie
    Hong Zhiliang
    JOURNAL OF SEMICONDUCTORS, 2013, 34 (05)
  • [24] Reliable Motion Artifact Detection for ECG Monitoring Systems with Dry Electrodes
    Ottenbacher, Joerg
    Kirst, Malte
    Jatoba, Luciana
    Huflejt, Michal
    Grossmann, Ulrich
    Stork, Wilhelm
    2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 1695 - +
  • [25] A low-power portable ECG sensor interface with dry electrodes
    浦小飞
    万磊
    张辉
    秦亚杰
    洪志良
    Journal of Semiconductors, 2013, (05) : 104 - 109
  • [26] Flexible polymeric dry electrodes for the long-term monitoring of ECG
    Baek, Ju-Yeoul
    An, Jin-Hee
    Choi, Jong-Min
    Park, Kwang-Suk
    Lee, Sang-Hoon
    SENSORS AND ACTUATORS A-PHYSICAL, 2008, 143 (02) : 423 - 429
  • [27] Skin-Potential Variation Insensitive Dry Electrodes for ECG Recording
    Pei, Weihua
    Zhang, He
    Wang, Yijun
    Guo, Xuhong
    Xing, Xiao
    Huang, Yong
    Xie, Yuxing
    Yang, Xiaowei
    Chen, Hongda
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2017, 64 (02) : 463 - 470
  • [28] Wearable Multi-lead ECG Recorder with Dry Metal Electrodes
    Hsu, Terng-Ren
    Hsu, Terng-Yin
    Yang, Shang-Yi
    Huang, Wei-Hsin
    Ou, Zong-Cheng
    Fan, Ching-Chih
    2016 11TH INTERNATIONAL MICROSYSTEMS, PACKAGING, ASSEMBLY AND CIRCUITS TECHNOLOGY CONFERENCE (IMPACT-IAAC 2016), 2016, : 73 - 76
  • [29] Development of Flexible Dry ECG Electrodes Based on MWCNT/PDMS Composite
    Chlaihawi, Amer Abdulmahdi
    Narakathu, Binu Baby
    Emamian, Sepehr
    Eshkeiti, Ali
    Reddy, Sai Guruva Avuthu
    Bazuin, Bradley J.
    Atashbar, Massood Z.
    2015 IEEE SENSORS, 2015, : 221 - 224
  • [30] Colophony-induced contact dermatitis due to ECG electrodes in an infant
    Oestmann, Elsbeth
    Philipp, Sandra
    Zuberbier, Torsten
    Worm, Margitta
    CONTACT DERMATITIS, 2007, 56 (03) : 177 - U8