Reliable Motion Artifact Detection for ECG Monitoring Systems with Dry Electrodes

被引:34
|
作者
Ottenbacher, Joerg [1 ]
Kirst, Malte [2 ]
Jatoba, Luciana [1 ]
Huflejt, Michal [3 ]
Grossmann, Ulrich [1 ]
Stork, Wilhelm [1 ]
机构
[1] Univ Karlsruhe, Inst Informat Proc Technol, Kaiserstr 12, D-76131 Karlsruhe, Germany
[2] FZI Res Ctr Informat Technol, D-76131 Karlsruhe, Germany
[3] Univ Hamburg, Dept Comp Sci, Hamburg, Germany
关键词
D O I
10.1109/IEMBS.2008.4649502
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Reliable signals are the basic prerequisite for most mobile ECG monitoring applications. Especially when signals are analyzed automatically, capable motion artifact detection algorithms are of great importance. This article presents different artifact detection algorithms for ECG systems with dry electrodes. The algorithms are based on the measurement of additional parameters that are correlated with the artifacts. We describe a mobile measurement system and the procedure used for the evaluation of these algorithms. The algorithms are assessed based upon their effect on QRS detection. The best algorithm improved sensitivity (Se) from 98.7% to 99.8% and positive predictive value (+P) from 98.3% to 99.9%, while 15% of the signal was marked as artifact. This corresponds to a decrease in false positive and false negative detected beats by 89.9%. Different metrics to evaluate the performance of an artifact detection algorithm are presented.
引用
收藏
页码:1695 / +
页数:2
相关论文
共 50 条
  • [1] An approach to reliable motion artifact detection for mobile long-term ECG monitoring systems using dry electrodes
    Ottenbacher, J.
    Kirst, M.
    Jatoba, L.
    Grossmann, U.
    Stork, W.
    [J]. IV LATIN AMERICAN CONGRESS ON BIOMEDICAL ENGINEERING 2007, BIOENGINEERING SOLUTIONS FOR LATIN AMERICA HEALTH, VOLS 1 AND 2, 2008, 18 (1,2): : 440 - +
  • [2] Novel dry electrodes for ECG monitoring
    Gruetzmann, Anna
    Hansen, Stefan
    Mueller, Joerg
    [J]. PHYSIOLOGICAL MEASUREMENT, 2007, 28 (11) : 1375 - 1390
  • [3] Motion artifact removal based on periodical property for ECG monitoring with wearable systems
    Zou, Chen
    Qin, Yajie
    Sun, Chenglu
    Li, Wei
    Chen, Wei
    [J]. PERVASIVE AND MOBILE COMPUTING, 2017, 40 : 267 - 278
  • [4] Motion Artifact Removal Based on ICA for Ambulatory ECG Monitoring
    Tian, Shudong
    Han, Jun
    Yang, Jianwei
    Zhou, Lijun
    Zeng, Xiaoyang
    [J]. PROCEEDINGS OF 2015 IEEE 11TH INTERNATIONAL CONFERENCE ON ASIC (ASICON), 2015,
  • [5] Development of a Technique for Cancelling Motion Artifact in Ambulatory ECG Monitoring System
    Jeong, Do-Un
    Kim, Se-Jin
    [J]. THIRD 2008 INTERNATIONAL CONFERENCE ON CONVERGENCE AND HYBRID INFORMATION TECHNOLOGY, VOL 1, PROCEEDINGS, 2008, : 954 - 961
  • [6] ARTIFACT AND SAFETY IN ECG MONITORING
    JONES, PL
    [J]. PROCEEDINGS OF THE ROYAL SOCIETY OF MEDICINE-LONDON, 1973, 66 (12): : 1211 - 1215
  • [7] A NOVEL QRS COMPLEX DETECTION ON ECG WITH MOTION ARTIFACT DURING EXERCISE
    Kim, Youngchun
    Tewfik, Ahmed H.
    [J]. 2015 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH, AND SIGNAL PROCESSING (ICASSP), 2015, : 972 - 976
  • [8] Transferring an Artifact Handling System into a Mobile Long-term ECG Device with Dry Electrodes
    Kirst, Malte
    Lamparth, Stefan
    Fuhrhop, Silvester
    Ottenbacher, Joerg
    Kunze, Christophe
    [J]. WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 4: IMAGE PROCESSING, BIOSIGNAL PROCESSING, MODELLING AND SIMULATION, BIOMECHANICS, 2010, 25 : 942 - 945
  • [9] Flexible polymeric dry electrodes for the long-term monitoring of ECG
    Baek, Ju-Yeoul
    An, Jin-Hee
    Choi, Jong-Min
    Park, Kwang-Suk
    Lee, Sang-Hoon
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 2008, 143 (02) : 423 - 429
  • [10] Quick ECG Segmentation, Artifact Detection and Risk Estimation Methods for On-Line Holter Monitoring Systems
    Szilagyi, L.
    Szilagyi, S. M.
    Frigy, A.
    David, L.
    Benyo, Z.
    [J]. WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 1021 - +