On the role of material properties in ascending thoracic aortic aneurysms

被引:24
|
作者
Cosentino, Federica [1 ,2 ]
Agnese, Valentina [3 ]
Raffa, Giuseppe M. [3 ]
Gentile, Giovanni [3 ]
Bellavia, Diego [3 ]
Zingales, Massimiliano [4 ]
Pilato, Michele [3 ]
Pasta, Salvatore [2 ,3 ]
机构
[1] Univ Palermo, Biomed Dept Internal Med & Special DIBIMIS, Piazza Clin 2, I-90128 Palermo, Italy
[2] Fdn Ri MED, Via Bandiera 11, I-90133 Palermo, Italy
[3] IRCCS, ISMETT, Dept Treatment & Study Cardiothorac Dis & Cardiot, Via Tricomi 5, I-90127 Palermo, Italy
[4] Univ Palermo, Dept Civil, Environm, Aerosp,Mat Engn DICAM, Viale Sci Ed 8, I-90128 Palermo, Italy
关键词
Ascending aortic aneurysm; Inverse approach; Material parameters; Aortic aneurysm failure; Finite-element analysis; WALL SHEAR-STRESS; MECHANICAL-PROPERTIES; INVERSE METHOD; VALVE; QUANTIFICATION; DILATATION; PREDICTORS; DISSECTION; RISK;
D O I
10.1016/j.compbiomed.2019.04.022
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
One of the obstacles standing before the biomechanical analysis of an ascending thoracic aortic aneurysm (ATAA) is the difficulty in obtaining patient-specific material properties. This study aimed to evaluate differences on ATAA-related stress predictions resulting from the elastostatic analysis based on the optimization of arbitrary material properties versus the application of patient-specific material properties determined from ex-vivo biaxial testing. Specifically, the elastostatic analysis relies the on the fact that, if the aortic wall stress does not depend on material properties, the aorta has to be statistically determinate. Finite element analysis (FEA) was applied to a group of nine patients who underwent both angio-CT imaging to reconstruct ATAA anatomies and surgical repair of diseased aorta to collect tissue samples for experimental material testing. Tissue samples cut from excised ATAA rings were tested under equibiaxial loading conditions to obtain experimentally-derived material parameters by fitting stress-strain profiles. FEAs were carried out using both optimized and experimentally-derived material parameters to predict and compare the stress distribution using the mean absolute percentage error (MAPE). Although physiological strains were below yield point (range of 0.08-0.25), elastostatic analysis led to errors on the stress predictions that depended on the type of constitutive model (highest MAPE of 0.7545 for Yeoh model and 0.7683 for Fung model) and ATAA geometry (lowest MAPE of 0.0349 for patient P.7). Elastostatic analysis needs better understanding of its application for determining aneurysm mechanics, and patient-specific material parameters are essential for reliable accurate stress predictions in ATAAs.
引用
收藏
页码:70 / 78
页数:9
相关论文
共 50 条
  • [21] Hyperplastic cellular remodeling of the media in ascending thoracic aortic aneurysms
    Tang, PCY
    Coady, MA
    Lovoulos, C
    Dardik, A
    Aslan, M
    Elefteriades, JA
    Tellides, G
    CIRCULATION, 2005, 112 (08) : 1098 - 1105
  • [22] The anaesthetic management of patients with thoracic ascending aortic aneurysms: A review
    Silvay, George
    Lurie, Jacob M.
    Casale, Marc
    JOURNAL OF PERIOPERATIVE PRACTICE, 2021, 31 (7-8) : 281 - 288
  • [23] Predictive Models with Patient Specific Material Properties for the Biomechanical Behavior of Ascending Thoracic Aneurysms
    Olfa Trabelsi
    Ambroise Duprey
    Jean-Pierre Favre
    Stéphane Avril
    Annals of Biomedical Engineering, 2016, 44 : 84 - 98
  • [24] Predictive Models with Patient Specific Material Properties for the Biomechanical Behavior of Ascending Thoracic Aneurysms
    Trabelsi, Olfa
    Duprey, Ambroise
    Favre, Jean-Pierre
    Avril, Stephane
    ANNALS OF BIOMEDICAL ENGINEERING, 2016, 44 (01) : 84 - 98
  • [25] Characteristics and Outcomes of Ascending Versus Descending Thoracic Aortic Aneurysms
    Vapnik, Joshua S.
    Kim, Joon. Bum
    Isselbacher, Eric M.
    Ghoshhajra, Brian B.
    Cheng, Yisha
    Sundt, Thoralf M., III
    MacGillivray, Thomas E.
    Cambria, Richard P.
    Lindsay, Mark E.
    AMERICAN JOURNAL OF CARDIOLOGY, 2016, 117 (10): : 1683 - 1690
  • [26] Cannulation of the ascending aorta in left thoracotomy for thoracic aortic aneurysms
    Turkoz, Riza
    GuIcan, Oner
    Demirturk, Orhan Saim
    Turkoz, Ayda
    HEART SURGERY FORUM, 2007, 10 (01): : 1 - 3
  • [27] Thoracic aortic aneurysms: Role of echocardiography
    Goldstein, SA
    Lindsay, J
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 1996, 13 (02): : 213 - 232
  • [28] Evidence in Clinical Studies for the Role of Wall Thickness in Ascending Thoracic Aortic Aneurysms: A Scoping Review
    Debeij, Gijs P.
    Parikh, Shaiv
    Delhaas, Tammo
    Bidar, Elham
    Reesink, Koen D.
    BIOENGINEERING-BASEL, 2023, 10 (08):
  • [29] Local mechanical properties of human ascending thoracic aneurysms
    Davis, Frances M.
    Luo, Yuanming
    Avril, Stephane
    Duprey, Ambroise
    Lu, Jia
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2016, 61 : 235 - 249
  • [30] Ascending Aortic Aneurysms
    Debus, E. S.
    GEFASSCHIRURGIE, 2012, 17 (03): : 170 - 170