Improving broadband ultrasound attenuation assessment in cancellous bone by mitigating the influence of cortical bone: Phantom and in-vitro study

被引:5
|
作者
Tasinkevych, Yuriy [1 ]
Falinska, Katarzyna [1 ]
Lewin, Peter A. [2 ]
Litniewski, Jerzy [1 ]
机构
[1] Polish Acad Sci, Inst Fundamental Technol Res, Dept Ultrasound, Warsaw, Poland
[2] Drexel Univ, Philadelphia, PA 19104 USA
关键词
Broadband ultrasound attenuation; Correction of influence of cortical bone; Trabecular bone; X-RAY ABSORPTIOMETRY; TRABECULAR BONE; ELDERLY-WOMEN; HIP FRACTURE; SLOW WAVES; BACKSCATTER; TRANSMISSION; PARAMETERS; DENSITY; OSTEOPOROSIS;
D O I
10.1016/j.ultras.2018.06.018
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The purpose of this work was to present a new approach that allows the influence of cortical bone on non-invasive measurement of broadband ultrasound attenuation (BUA) to be corrected. The method, implemented here at 1 MHz makes use of backscattered signal and once refined and clinically confirmed, it would offer an alternative to ionizing radiation based methods, such as DEXA (Dual-energy X-ray absorptiometry), quantitative computed tomography (QCT), radiographic absorptiometry (RA) or single X-ray absorptiometry (SXA), which are clinically approved for assessment of progress of osteoporosis. In addition, as the method employs reflected waves, it might substantially enhance the applicability of BUA - from being suitable to peripheral bones only it would extend this applicability to include such embedded bones as hip and femoral neck. The proposed approach allows the cortical layer parameters used for correction and the corrected value and parameter of the cancellous bone (BUA) to be determined simultaneously from the single (pulse-echo) bone backscattered wave; to the best of the authors' knowledge such approach was not previously reported. The validity of the method was tested using acoustic data obtained from a custom-designed bone-mimicking phantom and a calf femur. The relative error of the attenuation coefficient assessment was determined to be 3.9% and 4.7% for the bone phantom and calf bone specimens, respectively. When the cortical shell influence was not taken into account the corresponding errors were considerably higher 8.3% (artificial bone) and 9.2% (calf femur). As indicated above, once clinically proven, the use of this BUA measurement technique in reflection mode would augment diagnostic power of the attending physician by permitting to include bones, which are not accessible for transmission mode evaluation, e.g. hip, spine, humerus and femoral neck.
引用
收藏
页码:382 / 390
页数:9
相关论文
共 46 条
  • [1] A critical assessment of the in-vitro measurement of cortical bone stiffness with ultrasound
    Peralta, L.
    Cai, X.
    Laugier, P.
    Grimal, Q.
    ULTRASONICS, 2017, 80 : 119 - 126
  • [2] Fractal dimension predicts broadband ultrasound attenuation in stereolithography models of cancellous bone
    Langton, CM
    Whitehead, MA
    Haire, TJ
    Hodgskinson, R
    PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (02): : 467 - 471
  • [3] ULTRASOUND STUDY OF BONE IN-VITRO
    ANTICH, PP
    REEVE
    CALCIFIED TISSUE INTERNATIONAL, 1993, 53 : S157 - S161
  • [4] Broadband ultrasound attenuation value dependence on bone width in vitro
    Serpe, LJ
    Rho, JY
    PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (01): : 197 - 202
  • [5] Numerical and experimental study on the wave attenuation in bone - FDTD simulation of ultrasound propagation in cancellous bone
    Nagatani, Yoshiki
    Mizuno, Katsunori
    Saeki, Takashi
    Matsukawa, Mami
    Sakaguchi, Takefumi
    Hosoi, Hiroshi
    ULTRASONICS, 2008, 48 (6-7) : 607 - 612
  • [6] In vivo study of the influence of gravity on cortical and cancellous bone velocity
    Antich, PP
    Mehta, S
    Daphtary, M
    Lewis, M
    Smith, B
    Pak, CYC
    ACOUSTICAL IMAGING, VOL 24, 2000, 24 : 301 - 308
  • [7] Simultaneous estimation of cortical bone thickness and acoustic wave velocity using a multivariable optimization approach: Bone phantom and in-vitro study
    Tasinkevych, Yuriy
    Podhajecki, Jerzy
    Falinska, Katarzyna
    Litniewski, Jerzy
    ULTRASONICS, 2016, 65 : 105 - 112
  • [8] A CONTACT METHOD FOR THE ASSESSMENT OF ULTRASONIC VELOCITY AND BROAD-BAND ATTENUATION IN CORTICAL AND CANCELLOUS BONE
    LANGTON, CM
    ALI, AV
    RIGGS, CM
    EVANS, GP
    BONFIELD, W
    CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1990, 11 (03): : 243 - 249
  • [9] Frequency dependence of ultrasonic attenuation in bovine cortical bone:: An in vitro study
    Sasso, Magali
    Haiat, Guillaume
    Yamato, Yu
    Naili, Salah
    Matsukawa, Mami
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2007, 33 (12): : 1933 - 1942
  • [10] Prediction of biomechanical properties of cancellous bone using ultrasound bone velocity (UBV) and various types of bone densities: An in vitro study.
    Drozdzowska, B
    Pluskiewicz, W
    Przedlacki, J
    OSTEOPOROSIS INTERNATIONAL, 2000, 11 : 35 - 35