Evaluation of an application for intensity-based deformable image registration and dose accumulation in radiotherapy

被引:26
|
作者
Thor, Maria [1 ,2 ]
Andersen, Else S. [2 ]
Petersen, Jorgen B. B. [2 ]
Sorensen, Thomas S. [3 ]
Noe, Karsten O. [4 ,5 ]
Tanderup, Kari [2 ]
Bentzen, Lise [3 ]
Elstrom, Ulrik V. [2 ]
Hoyer, Morten [3 ]
Muren, Ludvig P. [2 ,3 ]
机构
[1] Mem Sloan Kettering Canc Ctr, Dept Med Phys, New York, NY 10065 USA
[2] Aarhus Univ Hosp, Dept Med Phys, DK-8000 Aarhus, Denmark
[3] Aarhus Univ Hosp, Dept Oncol, DK-8000 Aarhus, Denmark
[4] Alexandra Inst, Comp Graph Lab, Aarhus, Denmark
[5] Aarhus Univ, Dept Comp Sci, DK-8000 Aarhus, Denmark
关键词
PROSTATE-CANCER; PLANNING ORGAN; LYMPH-NODES; RECTUM; MOTION; PREDICTION; MORBIDITY; PROPAGATION; ROBUSTNESS; THERAPY;
D O I
10.3109/0284186X.2014.928742
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background. Methods to accurately accumulate doses in radiotherapy (RT) are important for tumour and normal tissues being influenced by geometric uncertainties. The purpose of this study was to investigate a pre-release deformable image registration (DIR)-based dose accumulation application, in the setting of prostate RT. Material and methods. Initially accumulated bladder and prostate doses were assessed (based on 8-9 repeat CT scans/patient) for nine prostate cancer patients using an intensity-based DIR and dose accumulation algorithm as provided by the Dynamic Adaptive Radiation Therapy (DART) software. The accumulated bladder and prostate dose-volume histograms (DVHs) were compared on a range of parameters (paired Wilcoxon signed-rank test, 5% significance level) to DVHs derived using an in-house developed dose accumulation method based on biomechanical, contour-driven DIR (SurfaceRegistration). Finally, both these accumulated dose distributions were compared to the 'static' DVH, assessed from the planning CT. Results. Over the population, doses accumulated with DART were overall lower than those from SurfaceRegistration (p<0.05: D-2%, gEUD and NTCP (bladder); D-min (prostate)). The magnitude of these differences peaked for the bladder gEUD with a population median of 47 Gy for DART versus 57 Gy for SurfaceRegistration. Across the ten bladder dose/volume parameters investigated, the most pronounced individual differences were observed between the 'accumulated' DVHs and the 'static' DVHs, with deviations in mean dose up to 22 Gy. Conclusion. Substantial and significant differences were observed in the dose distributions between the two investigated DIR-based dose accumulation applications. The most pronounced individual differences were seen for the bladder and relative to the planned dose distribution, encouraging the use of repeat imaging data in RT planning and evaluation for this organ.
引用
收藏
页码:1329 / 1336
页数:8
相关论文
共 50 条
  • [31] Evaluation of Deformable Image Registration-Based Dose Accumulation for Parotid Glands in Head and Neck Adaptive Radiotherapy and its Impact on Prediction of Xerostomia
    Gan, Y.
    Langendijk, J. A.
    Oldehinkel, E.
    Lin, Z.
    Both, S.
    Brouwer, C. L.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2022, 114 (03): : E591 - E591
  • [32] Evaluation of deformable image registration methods for dose monitoring in head and neck adaptive radiotherapy
    Rigaud, B.
    Simon, A.
    Castelli, J.
    Gobeli, M.
    Arango, J. D. Ospina
    Cazoulat, G.
    Henry, O.
    Haigron, P.
    De Crevoisier, R.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S488 - S489
  • [33] Evolutionary Intensity-based Medical Image Registration: A Review
    Valsecchi, Andrea
    Damas, Sergio
    Santamaria, Jose
    CURRENT MEDICAL IMAGING, 2013, 9 (04) : 283 - 297
  • [34] Intensity-based image registration using scatter search
    Valsecchi, Andrea
    Damas, Sergio
    Santamaria, Jose
    Marrakchi-Kacem, Linda
    ARTIFICIAL INTELLIGENCE IN MEDICINE, 2014, 60 (03) : 151 - 163
  • [35] A New Similarity Measure for intensity-Based Image Registration
    Shirpour, Mohsen
    Aghajani, Khadijeh
    Manzuri-Shalmani, M. T.
    2014 4TH INTERNATIONAL CONFERENCE ON COMPUTER AND KNOWLEDGE ENGINEERING (ICCKE), 2014, : 227 - 232
  • [36] Deep learning based uncertainty prediction of deformable image registration for contour propagation and dose accumulation in online adaptive radiotherapy
    Smolders, A.
    Lomax, A.
    Weber, D. C.
    Albertini, F.
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (24):
  • [37] Applying Multi-Metric Deformable Image Registration for Dose Accumulation in Combined Cervical Cancer Radiotherapy
    Fu, Qi
    Xie, Xin
    Xu, Yingjie
    Zuo, Jing
    Yang, Xi
    Xia, Wenlong
    An, Jusheng
    Huang, Manni
    Yan, Hui
    Dai, Jianrong
    JOURNAL OF PERSONALIZED MEDICINE, 2023, 13 (02):
  • [38] The impact of robustness of deformable image registration on contour propagation and dose accumulation for head and neck adaptive radiotherapy
    Zhang, Lian
    Wang, Zhi
    Shi, Chengyu
    Long, Tengfei
    Xu, X. George
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (04): : 185 - 194
  • [39] Ultrasound calibration using intensity-based image registration: For application in cardiac catheterization procedures
    Ma, Y. L.
    Rhode, K. S.
    Gao, G.
    King, A. P.
    Chinchapatnam, P.
    Schaeffter, T.
    Hawkes, D. J.
    Razavi, R.
    Penney, G. P.
    MEDICAL IMAGING 2008: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, PTS 1 AND 2, 2008, 6918
  • [40] A Controlled Study of Dose Accumulation in Intensity-Modulated Radiotherapy for Non-Small Cell Lung Cancer Based On Rigid Registration and Deformable Registration
    Ren, J.
    Gong, G.
    Yin, Y.
    Quan, H.
    MEDICAL PHYSICS, 2019, 46 (06) : E385 - E385