Evaluation of an application for intensity-based deformable image registration and dose accumulation in radiotherapy

被引:26
|
作者
Thor, Maria [1 ,2 ]
Andersen, Else S. [2 ]
Petersen, Jorgen B. B. [2 ]
Sorensen, Thomas S. [3 ]
Noe, Karsten O. [4 ,5 ]
Tanderup, Kari [2 ]
Bentzen, Lise [3 ]
Elstrom, Ulrik V. [2 ]
Hoyer, Morten [3 ]
Muren, Ludvig P. [2 ,3 ]
机构
[1] Mem Sloan Kettering Canc Ctr, Dept Med Phys, New York, NY 10065 USA
[2] Aarhus Univ Hosp, Dept Med Phys, DK-8000 Aarhus, Denmark
[3] Aarhus Univ Hosp, Dept Oncol, DK-8000 Aarhus, Denmark
[4] Alexandra Inst, Comp Graph Lab, Aarhus, Denmark
[5] Aarhus Univ, Dept Comp Sci, DK-8000 Aarhus, Denmark
关键词
PROSTATE-CANCER; PLANNING ORGAN; LYMPH-NODES; RECTUM; MOTION; PREDICTION; MORBIDITY; PROPAGATION; ROBUSTNESS; THERAPY;
D O I
10.3109/0284186X.2014.928742
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background. Methods to accurately accumulate doses in radiotherapy (RT) are important for tumour and normal tissues being influenced by geometric uncertainties. The purpose of this study was to investigate a pre-release deformable image registration (DIR)-based dose accumulation application, in the setting of prostate RT. Material and methods. Initially accumulated bladder and prostate doses were assessed (based on 8-9 repeat CT scans/patient) for nine prostate cancer patients using an intensity-based DIR and dose accumulation algorithm as provided by the Dynamic Adaptive Radiation Therapy (DART) software. The accumulated bladder and prostate dose-volume histograms (DVHs) were compared on a range of parameters (paired Wilcoxon signed-rank test, 5% significance level) to DVHs derived using an in-house developed dose accumulation method based on biomechanical, contour-driven DIR (SurfaceRegistration). Finally, both these accumulated dose distributions were compared to the 'static' DVH, assessed from the planning CT. Results. Over the population, doses accumulated with DART were overall lower than those from SurfaceRegistration (p<0.05: D-2%, gEUD and NTCP (bladder); D-min (prostate)). The magnitude of these differences peaked for the bladder gEUD with a population median of 47 Gy for DART versus 57 Gy for SurfaceRegistration. Across the ten bladder dose/volume parameters investigated, the most pronounced individual differences were observed between the 'accumulated' DVHs and the 'static' DVHs, with deviations in mean dose up to 22 Gy. Conclusion. Substantial and significant differences were observed in the dose distributions between the two investigated DIR-based dose accumulation applications. The most pronounced individual differences were seen for the bladder and relative to the planned dose distribution, encouraging the use of repeat imaging data in RT planning and evaluation for this organ.
引用
收藏
页码:1329 / 1336
页数:8
相关论文
共 50 条
  • [21] Deformable Image Registration for Dose Mapping and Dose Accumulation: Techniques and Challenges
    Chetty, Indrin
    Brock, Kristy
    Rosu-Bubulac, M.
    Swamidas, J.
    MEDICAL PHYSICS, 2019, 46 (06) : E410 - E411
  • [22] DEFORMABLE IMAGE REGISTRATION-BASED DOSE ACCUMULATION FOR LUNG REIRRADIATION CASES
    Di Francesco, Marco
    Popovic, Marija
    Serban, Monica
    RADIOTHERAPY AND ONCOLOGY, 2023, 186 : S123 - S123
  • [23] Deformable Image Registration Based Delivered Dose Estimation for Head and Neck Radiotherapy
    Kumarasiri, A.
    Liu, C.
    Chetvertkov, M.
    Gordon, J.
    Siddiqui, F.
    Chetty, I.
    Kim, J.
    MEDICAL PHYSICS, 2014, 41 (06) : 191 - 192
  • [24] Intensity-based robust similarity for multimodal image registration
    Du, J
    Tang, SY
    Jiang, TZ
    Lu, ZS
    INTERNATIONAL JOURNAL OF COMPUTER MATHEMATICS, 2006, 83 (01) : 49 - 57
  • [25] The dose accumulation and the impact of deformable image registration on dose reporting parameters in a moving patient undergoing proton radiotherapy
    Razdevsek, Gasper
    Simoncic, Urban
    Snoj, Luka
    Studen, Andrej
    RADIOLOGY AND ONCOLOGY, 2022, 56 (02) : 248 - 258
  • [26] Intensity-Based Image Registration by Nonparametric Local Smoothing
    Xing, Chen
    Qiu, Peihua
    IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 2011, 33 (10) : 2081 - 2092
  • [27] Revisiting Intensity-Based Image Registration Applied to Mammography
    Diez, Yago
    Oliver, Arnau
    Llado, Xavier
    Freixenet, Jordi
    Marti, Joan
    Carles Vilanova, Joan
    Marti, Robert
    IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2011, 15 (05): : 716 - 725
  • [28] elastix: A Toolbox for Intensity-Based Medical Image Registration
    Klein, Stefan
    Staring, Marius
    Murphy, Keelin
    Viergever, Max A.
    Pluim, Josien P. W.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2010, 29 (01) : 196 - 205
  • [29] Evaluation of intensity-based deformable registration of multi-parametric MRI for radiomics analysis of the prostate
    Alley, Stephanie
    Fedorov, Andrey
    Menard, Cynthia
    Kadoury, Samuel
    MEDICAL IMAGING 2020: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2021, 11317
  • [30] Deformable Registration for Dose Accumulation
    Chetty, Indrin J.
    Rosu-Bubulac, Mihaela
    SEMINARS IN RADIATION ONCOLOGY, 2019, 29 (03) : 198 - 208