The influence of the dose assessment method on the LET dependence of the relative luminescence efficiency of LiF:Mg,Ti and LiF:Mg,Cu,P

被引:19
|
作者
Parisi, Alessio [1 ,2 ]
Van Hoey, Olivier [1 ]
Megret, Patrice [2 ]
Vanhavere, Filip [1 ]
机构
[1] CEN, Belgian Nucl Res Ctr SCK, Boeretang 200, Mol, Belgium
[2] Univ Mons, Fac Engn, Blvd Dolez 31, Mons, Belgium
关键词
LiF:Mg; Ti; Cu; P; TLD; Efficiency; LET; TEMPERATURE RATIO HTR; IONIZATION DENSITY; GLOW-CURVE; THERMOLUMINESCENT EFFICIENCY; COSMIC-RADIATION; LIF DETECTORS; ENERGY IONS; LIF-MG; TI; TL;
D O I
10.1016/j.radmeas.2017.02.001
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Thermoluminescent detectors (TLDs) are solid state detectors commonly used for dose monitoring and dose mapping in many earth and space applications. Among all the crystals available, the ones based on lithium fluoride (LiF) are the most widely spread and studied around the world. In the last years the use of these TLDs in complex heavy charged particles (HCPs) fields, as in spacecraft or in radiotherapy beams, has grown rapidly leading to the necessity of an accurate characterization of the detectors' response in these radiation environments. In this work, (LiF)-Li-6:Mg,Ti, (LiF)-Li-7:Mg,Ti, (LiF)-Li-6:Mg,Cu,P and (LiF)-Li-7:Mg,Cu,P detectors were exposed to different radiation qualities in order to investigate the dependence of their relative luminescence efficiency on the linear energy transfer (LET) of the incident particles. The measured efficiencies were in good agreement with literature. In relation to this issue, different dose assessment methods, i.e. peak height, signal integration over different regions of interest (ROIs) and glow curve deconvolution, were compared and their influence on the measured relative luminescence efficiency values was assessed. For both LiF:Mg,Ti and LiF:Mg,Cu,P detectors, no relevant differences were found in the relative luminescence efficiency evaluated by means of main peak height, main peak ROI and main peak deconvolution. On the other hand, if the integration of the signal is extended to the high temperature zone (248-310 degrees C) of LiF:Mg,Ti or the low temperature zone (125-185 degrees C) of LiF:Mg,Cu,P, significant deviations were found. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:34 / 40
页数:7
相关论文
共 50 条
  • [21] EVALUATION OF THE PERFORMANCE OF TWO LiF:Mg,Ti AND LiF:Mg,Cu,P DOSEMETERS FOR EXTREMITY MONITORING
    Freire, L. C.
    Pereira, M. F.
    Calado, A. M.
    Santos, L. M.
    Cardoso, J. V.
    Alves, J. G.
    RADIATION PROTECTION DOSIMETRY, 2011, 144 (1-4) : 140 - 143
  • [22] Radio-photoluminescence of highly irradiated Lif:Mg,Ti and Lif:Mg,Cu,P detectors
    Mrozik, A.
    Bilski, P.
    Marczewska, B.
    Obryk, B.
    Hodyr, K.
    Gieszczyk, W.
    RADIATION MEASUREMENTS, 2014, 71 : 31 - 35
  • [23] Optical and thermoluminescence properties of LiF:Cu, LiF:Mg,Cu and LiF:Mg,Cu,P single crystals
    Chernov, V
    Mironenko, S
    Rogalev, B
    Bos, AJJ
    de Haas, JTM
    Delgado, A
    RADIATION MEASUREMENTS, 1998, 29 (3-4) : 365 - 372
  • [24] DOSE REASSESSMENT OF LIF-MG,CU,P
    DRISCOLL, CMH
    RADIATION PROTECTION DOSIMETRY, 1987, 19 (01) : 59 - 61
  • [25] Determination of self attenuation coefficient and relative TL efficiency of CaSO4:Dy, LiF:Mg,Cu,P and LiF:Mg,Ti TLDs - An alternate approach
    Bakshi, A. K.
    Chatterjee, S.
    Selvam, T. Palani
    Joshi, V. J.
    Chougaonkar, M. P.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2011, 269 (19): : 2107 - 2110
  • [26] A study on thermal degradation of LiF:Mg,Cu,P and LiF:Mg,Cu,Si
    Konnai, Akiko
    Ozasa, Naoto
    Lee, Jung-il
    RADIATION MEASUREMENTS, 2010, 45 (3-6) : 533 - 536
  • [27] MICRODOSIMETRIC MODELING OF THE RELATIVE LUMINESCENCE EFFICIENCY OF LiF:Mg,Cu,P (MCP) DETECTORS EXPOSED TO CHARGED PARTICLES
    Parisi, Alessio
    Van Hoey, Olivier
    Megret, Patrice
    Vanhavere, Filip
    RADIATION PROTECTION DOSIMETRY, 2019, 183 (1-2) : 172 - 176
  • [28] A comparative study on the thermal stability of LiF:Mg,Ti and LiF:Mg,Cu,P detectors for environmental monitoring
    Alves, JG
    Muñiz, JL
    Ros, JMG
    Delgado, A
    RADIATION PROTECTION DOSIMETRY, 1999, 85 (1-4) : 253 - 257
  • [30] Positron annihilation in thermoluminescent materials LiF:Mg, Ti and LiF:Mg, Cu, P and MgSO4
    Deng, Zouping
    Luo, Daling
    Zhu, Ziying
    Zhang, Chunxiang
    Li, Jingde
    He Jishu/Nuclear Techniques, 1998, 21 (02): : 89 - 93