Toric Intraocular Lens Calculations Using Ratio, of Anterior to Posterior Corneal Cylinder Power

被引:35
|
作者
Eom, Youngsub [1 ]
Rhim, Jay Won [1 ]
Kang, Su-Yeon [1 ]
Kim, Seong-Woo [1 ]
Song, Jong Suk [1 ]
Kim, Hyo Myung [1 ]
机构
[1] Korea Univ, Coll Med, Anam Hosp, Dept Ophthalmol, Seoul 136705, South Korea
关键词
ASTIGMATISM; CURVATURE;
D O I
10.1016/j.ajo.2015.07.011
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate the accuracy of toric intraocular lens (IOL) calculation using estimated total corneal astigmatism based on the anterior-to-posterior corneal cylinder power ratio according to the axis orientation of anterior corneal astigmatism. DESIGN: Retrospective cross-sectional study. METHODS: Nine hundred twenty-eight eyes of 928 reference subjects and 20 cataract patients (20 eyes) implanted with a toric IOL were enrolled. Linear regression analysis parameters (beta(0) and beta(1)) of relationship between the simulated keratometry cylinder (Cyl(SimK)) and posterior corneal cylinder power of reference subjects were used to calculate the estimated posterior corneal astigmatism (-[beta(1) x cyl(SimK) + beta(0)] @ 90). When regression analysis was not significant, estimated posterior corneal astigmatism was defined as the negative value of the mean posterior corneal cylinder power @ 90. Estimated total corneal astigmatism was defined as the vectorial sum of anterior corneal astigmatism and estimated posterior corneal astigmatism. Residual astigmatism error, predicted using SimK, was compared with that predicted using estimated total corneal astigmatism. RESULTS: Estimated posterior corneal astigmatism was determined to be -(0.15 x Cyl(SimK) + 0.22) @ 90 in eyes with with-the-rule astigmatism, -(0.05 x Cyl(SimK) + 0.27) @ 90 in oblique astigmatism, and -0.27 @ 90 in against-the-rule astigmatism. The median magnitude of the predicted residual astigmatism error calculated using estimated total corneal astigmatism (0.30 cylinder diopters) was significantly smaller than that calculated with SimK (0.50 cylinder diopters). CONCLUSIONS: Toric IOL calculations using estimated total corneal astigmatism based on the anterior-to-posterior corneal cylinder power ratio provided a more appropriate toric IOL cylinder power than calculations using SimK astigmatism. (C) 2015 by Elsevier Inc. All rights reserved.
引用
收藏
页码:717 / 724
页数:8
相关论文
共 50 条
  • [1] |Accuracy of toric intraocular lens calculations using estimated versus measured posterior corneal astigmatism
    Segers, M. H. M.
    Abulafia, A.
    Webers, V. S. C.
    Verstraaten, J. -W.
    Vandevenne, M. M. S.
    Berendschot, T. T. J. M.
    Barrett, G. D.
    Nuijts, R. M. M. A.
    Dickman, M. M.
    ACTA OPHTHALMOLOGICA, 2023, 101 : 6 - 6
  • [2] Accuracy of Toric Intraocular Lens Calculations Using Estimated Versus Measured Posterior Corneal Astigmatism
    Segers, Maartje H. M.
    Abulafia, Adi
    Webers, Valentijn S. C.
    Verstraaten, Jan-Willem
    Vandevenne, Magali M. S.
    Berendschot, Tos T. J. M.
    Kan-Tor, Yoav
    Benjamini, Yuval
    Van Den Biggelaar, Frank J. H. M.
    Barrett, Graham D.
    Nuijts, Rudy M. M. A.
    Dickman, Mor M.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2024, 262 : 107 - 113
  • [3] Predicted vs measured posterior corneal astigmatism for toric intraocular lens calculations
    Shammas, H. John
    Yu, Fei
    Shammas, Maya C.
    Jivrajka, Renu
    Hakimeh, Christine
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2022, 48 (06): : 690 - 696
  • [4] Toric Intraocular Lens Outcome Using the Manufacturer's Prediction of Corneal Plane Equivalent Intraocular Lens Cylinder Power
    Goggin, Michael
    Moore, Sacha
    Esterman, Adrian
    ARCHIVES OF OPHTHALMOLOGY, 2011, 129 (08) : 1004 - 1008
  • [5] Refractive cylinder outcomes after calculating toric intraocular lens cylinder power using total corneal refractive power
    Davison, James A.
    Potvin, Richard
    CLINICAL OPHTHALMOLOGY, 2015, 9 : 1511 - 1517
  • [6] Comment on: Predicted vs measured posterior corneal astigmatism for toric intraocular lens calculations
    Tello, Alejandro
    Galvis, Virgilio
    Lugo, Ingrith K.
    Villamizar, Sylvia J.
    Serrano, Sergio E.
    Cadena, Laura del Pilar
    Rey, Juan Jose
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2022, 48 (10): : 1227 - 1228
  • [7] Impact of the anterior-posterior corneal radius ratio on intraocular lens power calculation errors
    Hasegawa, Asato
    Kojima, Takashi
    Yamamoto, Mana
    Kato, Yukihito
    Tamaoki, Akeno
    Ichikawa, Kazuo
    CLINICAL OPHTHALMOLOGY, 2018, 12 : 1549 - 1558
  • [8] Reply: Predicted vs measured posterior corneal astigmatism for toric intraocular lens calculations.
    Shammas, H. John
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2022, 48 (10): : 1228 - 1229
  • [9] Toric Intraocular Lens Calculation Considering Anterior Surgically Induced Astigmatism and Posterior Corneal Astigmatism
    Fernandez, Joaquin
    Rodriguez-Vallejo, Manuel
    Rocha-de-Lossada, Carlos
    Hueso, Elisa
    Pinero, David
    CURRENT EYE RESEARCH, 2022, 47 (01) : 25 - 31
  • [10] New algorithm for toric intraocular lens power calculation considering the posterior corneal astigmatism
    Canovas, Carmen
    Alarcon, Aixa
    Rosen, Robert
    Kasthurirangan, Sanjeev
    Ma, Joseph J. K.
    Koch, Douglas D.
    Piers, Patricia
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2018, 44 (02): : 168 - 174