Toric Intraocular Lens Outcome Using the Manufacturer's Prediction of Corneal Plane Equivalent Intraocular Lens Cylinder Power

被引:53
|
作者
Goggin, Michael [1 ]
Moore, Sacha [1 ]
Esterman, Adrian [2 ]
机构
[1] Univ Adelaide, S Australian Inst Ophthalmol, Adelaide, SA, Australia
[2] Univ S Australia, Sch Nursing & Midwifery, Adelaide, SA 5001, Australia
关键词
MICROINCISION CATARACT-SURGERY; ASTIGMATISM;
D O I
10.1001/archophthalmol.2011.178
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objectives: To describe the refractive outcome of toric intraocular lens (IOL) implantation by comparing the postoperative refractive astigmatism with the preoperative keratometric astigmatism target. Method: In a university department of a publicly funded hospital, 38 eyes of 29 patients underwent routine cataract surgery with insertion of a toric implant (SN60TT AcrySof Toric). Surgically induced astigmatism was derived using vector analysis of refractive outcome vs predicted postoperative keratometric astigmatism and compared with the targeted induced astigmatism. Results: Postoperative remaining refractive astigmatism of 0.97 diopters (D) was achieved vs a target of 0.61 D. A mean (SD) surgically induced astigmatism value of 1.78 (0.89) D was derived compared with a mean (SD) targeted induced astigmatism value of 1.58 (0.47) D (calculated by the manufacturer's online calculator, which predicts IOL corneal plane equivalent cylinder power and postoperative keratometric cylinder). Conclusions: Toric IOLs are a safe, predictable method of astigmatic correction. However, some remaining astigmatism is commonly present owing to the necessary nonzero astigmatic targets imposed by the steps between IOL cylinder powers, variability of axis, and power effects of surgical incisions as well as by underestimation of the corneal plane cylinder power of the IOLs by the manufacturer.
引用
收藏
页码:1004 / 1008
页数:6
相关论文
共 50 条
  • [1] Toric Intraocular Lens Calculations Using Ratio, of Anterior to Posterior Corneal Cylinder Power
    Eom, Youngsub
    Rhim, Jay Won
    Kang, Su-Yeon
    Kim, Seong-Woo
    Song, Jong Suk
    Kim, Hyo Myung
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2015, 160 (04) : 717 - 724
  • [2] Intraocular lens constant optimization in toric intraocular lens calculation using keratometry and total corneal power
    Liang, Jianheng
    Liu, Hui
    Zhou, Suowang
    Zhou, Lijing
    Qian, Zhuyun
    Jiang, Lihong
    Chen, Xu
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2023, 33 (01) : 230 - 238
  • [3] Accuracy of Ten Intraocular Lens Formulas in Spherical Equivalent of Toric Intraocular Lens Power Calculation
    Jingyi Shi
    Zehui Zhu
    Bin Hu
    Shuyi Qian
    Yalan Wang
    Pingjun Chang
    Yun-e Zhao
    Ophthalmology and Therapy, 2024, 13 : 1321 - 1342
  • [4] Accuracy of Ten Intraocular Lens Formulas in Spherical Equivalent of Toric Intraocular Lens Power Calculation
    Shi, Jingyi
    Zhu, Zehui
    Hu, Bin
    Qian, Shuyi
    Wang, Yalan
    Chang, Pingjun
    Zhao, Yun-e
    OPHTHALMOLOGY AND THERAPY, 2024, 13 (05) : 1321 - 1342
  • [5] Outcome of Toric Intraocular Lens Implantation After Adjusting for Anterior Chamber Depth and Intraocular Lens Sphere Equivalent Power Effects
    Goggin, Michael
    Moore, Sacha
    Esterman, Adrian
    ARCHIVES OF OPHTHALMOLOGY, 2011, 129 (08) : 998 - 1003
  • [6] Prediction of intraocular lens power using the lens haptic plane concept
    Norrby, NES
    Koranyi, G
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1997, 23 (02): : 254 - 259
  • [7] Refractive cylinder outcomes after calculating toric intraocular lens cylinder power using total corneal refractive power
    Davison, James A.
    Potvin, Richard
    CLINICAL OPHTHALMOLOGY, 2015, 9 : 1511 - 1517
  • [8] The Effect of Corneal Astigmatism Orientation on Toric Intraocular Lens Outcome
    Lowry, Eugene Alan
    Kasi, Sundeep
    Naseri, Ayman
    Blumberg, Seth
    Moriaria, Priya
    Schallhorn, Steven C.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [9] Effect of effective lens position on cylinder power of toric intraocular lenses
    Eom, Youngsub
    Kang, Su-Yeon
    Song, Jong Suk
    Kim, Yong Yeon
    Kim, Hyo Myung
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2015, 50 (01): : 26 - 32
  • [10] Effects of preoperative corneal astigmatism orientation on results with a low-cylinder-power toric intraocular lens
    Ernest, Paul
    Potvin, Richard
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (04): : 727 - 732