Toric Intraocular Lens Outcome Using the Manufacturer's Prediction of Corneal Plane Equivalent Intraocular Lens Cylinder Power

被引:53
|
作者
Goggin, Michael [1 ]
Moore, Sacha [1 ]
Esterman, Adrian [2 ]
机构
[1] Univ Adelaide, S Australian Inst Ophthalmol, Adelaide, SA, Australia
[2] Univ S Australia, Sch Nursing & Midwifery, Adelaide, SA 5001, Australia
关键词
MICROINCISION CATARACT-SURGERY; ASTIGMATISM;
D O I
10.1001/archophthalmol.2011.178
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objectives: To describe the refractive outcome of toric intraocular lens (IOL) implantation by comparing the postoperative refractive astigmatism with the preoperative keratometric astigmatism target. Method: In a university department of a publicly funded hospital, 38 eyes of 29 patients underwent routine cataract surgery with insertion of a toric implant (SN60TT AcrySof Toric). Surgically induced astigmatism was derived using vector analysis of refractive outcome vs predicted postoperative keratometric astigmatism and compared with the targeted induced astigmatism. Results: Postoperative remaining refractive astigmatism of 0.97 diopters (D) was achieved vs a target of 0.61 D. A mean (SD) surgically induced astigmatism value of 1.78 (0.89) D was derived compared with a mean (SD) targeted induced astigmatism value of 1.58 (0.47) D (calculated by the manufacturer's online calculator, which predicts IOL corneal plane equivalent cylinder power and postoperative keratometric cylinder). Conclusions: Toric IOLs are a safe, predictable method of astigmatic correction. However, some remaining astigmatism is commonly present owing to the necessary nonzero astigmatic targets imposed by the steps between IOL cylinder powers, variability of axis, and power effects of surgical incisions as well as by underestimation of the corneal plane cylinder power of the IOLs by the manufacturer.
引用
收藏
页码:1004 / 1008
页数:6
相关论文
共 50 条
  • [41] Determining the power of a thin toric intraocular lens in an astigmatic eye
    Mackenzie, GE
    Harris, WF
    OPTOMETRY AND VISION SCIENCE, 2002, 79 (10) : 667 - 671
  • [42] An evaluation of the accuracy of toric intraocular lens power calculation based on measured total corneal refractive power
    Yang, Zhi
    Zhou, Yanwen
    Jin, Tianru
    Li, Jingjing
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2023, 71 (02) : 541 - 546
  • [43] Toric intraocular lens power calculation in cataract patients with keratoconus
    Ton, Yokrat
    Barrett, Graham D.
    Kleinmann, Guy
    Levy, Adi
    Assia, Ehud I.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2021, 47 (11): : 1389 - 1397
  • [44] Exact Toric Intraocular Lens Calculations Using Currently Available Lens Constants
    Holladay, Jack T.
    ARCHIVES OF OPHTHALMOLOGY, 2012, 130 (07) : 946 - 947
  • [45] Assessment of toric intraocular lens alignment by a refractive power/corneal analyzer system and slitlamp observation
    Carey, Paul J.
    Leccisotti, Antonio
    McGilligan, Victoria E.
    Goodall, Ed A.
    Moore, C. B. Tara
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (02): : 222 - 229
  • [46] Comparison of Methodologies Using Estimated or Measured Values of Total Corneal Astigmatism for Toric Intraocular Lens Power Calculation
    Ferreira, Tiago B.
    Ribeiro, Paulo
    Ribeiro, Filomena J.
    O'Neill, Joao G.
    JOURNAL OF REFRACTIVE SURGERY, 2017, 33 (12) : 794 - 801
  • [47] Effect of corneal aberrations on intraocular lens power calculations
    Canovas, Carmen
    Abenza, Salome
    Alcon, Encarna
    Villegas, Eloy A.
    Marin, Jose M.
    Artal, Pablo
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (08): : 1325 - 1332
  • [48] Principles of corneal measurement for intraocular lens power calculation
    Findl, Oliver
    Hirnschall, Nino
    EXPERT REVIEW OF OPHTHALMOLOGY, 2016, 11 (02) : 93 - 99
  • [49] Accuracy of Intraocular Lens Power Prediction Using 9 Formula
    Kim, Kyung Wook
    Yi, Kayoung
    Shin, Young Joo
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2024, 65 (01): : 16 - 26
  • [50] Intraocular lens power calculations using a Scheimpflug camera to measure corneal power
    Xu, K.
    Hao, Y.
    Qi, H.
    BIOTECHNIC & HISTOCHEMISTRY, 2014, 89 (05) : 348 - 354