Toric Intraocular Lens Calculations Using Ratio, of Anterior to Posterior Corneal Cylinder Power

被引:35
|
作者
Eom, Youngsub [1 ]
Rhim, Jay Won [1 ]
Kang, Su-Yeon [1 ]
Kim, Seong-Woo [1 ]
Song, Jong Suk [1 ]
Kim, Hyo Myung [1 ]
机构
[1] Korea Univ, Coll Med, Anam Hosp, Dept Ophthalmol, Seoul 136705, South Korea
关键词
ASTIGMATISM; CURVATURE;
D O I
10.1016/j.ajo.2015.07.011
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate the accuracy of toric intraocular lens (IOL) calculation using estimated total corneal astigmatism based on the anterior-to-posterior corneal cylinder power ratio according to the axis orientation of anterior corneal astigmatism. DESIGN: Retrospective cross-sectional study. METHODS: Nine hundred twenty-eight eyes of 928 reference subjects and 20 cataract patients (20 eyes) implanted with a toric IOL were enrolled. Linear regression analysis parameters (beta(0) and beta(1)) of relationship between the simulated keratometry cylinder (Cyl(SimK)) and posterior corneal cylinder power of reference subjects were used to calculate the estimated posterior corneal astigmatism (-[beta(1) x cyl(SimK) + beta(0)] @ 90). When regression analysis was not significant, estimated posterior corneal astigmatism was defined as the negative value of the mean posterior corneal cylinder power @ 90. Estimated total corneal astigmatism was defined as the vectorial sum of anterior corneal astigmatism and estimated posterior corneal astigmatism. Residual astigmatism error, predicted using SimK, was compared with that predicted using estimated total corneal astigmatism. RESULTS: Estimated posterior corneal astigmatism was determined to be -(0.15 x Cyl(SimK) + 0.22) @ 90 in eyes with with-the-rule astigmatism, -(0.05 x Cyl(SimK) + 0.27) @ 90 in oblique astigmatism, and -0.27 @ 90 in against-the-rule astigmatism. The median magnitude of the predicted residual astigmatism error calculated using estimated total corneal astigmatism (0.30 cylinder diopters) was significantly smaller than that calculated with SimK (0.50 cylinder diopters). CONCLUSIONS: Toric IOL calculations using estimated total corneal astigmatism based on the anterior-to-posterior corneal cylinder power ratio provided a more appropriate toric IOL cylinder power than calculations using SimK astigmatism. (C) 2015 by Elsevier Inc. All rights reserved.
引用
收藏
页码:717 / 724
页数:8
相关论文
共 50 条
  • [31] Use of the Ratio of Posterior to Anterior Corneal Radii of Curvature to Improve the Accuracy of Intraocular Lens Power Calculation: Eom's Adjustment Method
    Eom, Youngsub
    Kim, Mingyu
    Lee, Hwa
    Suh, Young-Woo
    Song, Jong Suk
    Kim, Hyo Myung
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [32] Development of a program for toric intraocular lens calculation considering posterior corneal astigmatism, incision-induced posterior corneal astigmatism, and effective lens position
    Eom, Youngsub
    Ryu, Dongok
    Kim, Dae Wook
    Yang, Seul Ki
    Song, Jong Suk
    Kim, Sug-Whan
    Kim, Hyo Myung
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2016, 254 (10) : 1977 - 1986
  • [33] Development of a program for toric intraocular lens calculation considering posterior corneal astigmatism, incision-induced posterior corneal astigmatism, and effective lens position
    Youngsub Eom
    Dongok Ryu
    Dae Wook Kim
    Seul Ki Yang
    Jong Suk Song
    Sug-Whan Kim
    Hyo Myung Kim
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2016, 254 : 1977 - 1986
  • [34] Influence of posterior corneal astigmatism on the outcomes of toric intraocular lens implantation in eyes with oblique astigmatism
    Nakano, Shinichiro
    Iida, Masaharu
    Hasegawa, Yumi
    Hiraoka, Takahiro
    Oshika, Tetsuro
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2021, 65 (02) : 288 - 294
  • [35] Influence of posterior corneal astigmatism on the outcomes of toric intraocular lens implantation in eyes with oblique astigmatism
    Shinichiro Nakano
    Masaharu Iida
    Yumi Hasegawa
    Takahiro Hiraoka
    Tetsuro Oshika
    Japanese Journal of Ophthalmology, 2021, 65 : 288 - 294
  • [36] Effects of Calculator with Posterior Corneal Astigmatism on Toric Intraocular Lens Selection and Simulated Residual Astigmatism
    Hasegawa, Yumi
    Hiraoka, Takahiro
    Seki, Mariko
    Nakano, Shinichiro
    Oshika, Tetsuro
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [37] Toric multifocal intraocular lens implantation in a case of bilateral anterior and posterior lenticonus in Alport syndrome
    Ladi, Jeevan S.
    Shah, Nitant A.
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2016, 64 (11) : 847 - 849
  • [38] Total corneal astigmatism values for toric intraocular lens power calculation: Devices comparison
    Karamirad, Soroush
    Ghoreishi, Mohammad
    Mohamadynia, Mohadese
    Peyman, Mohammadreza
    Alemzadeh-Ansari, Mohammad Hasan
    Peyman, Alireza
    MEDICAL SCIENCE, 2021, 25 (110) : 917 - 923
  • [39] Use of Scheimpflug corneal anterior-posterior imaging in ray-tracing intraocular lens power calculation
    Miyata, Kazunori
    Otani, Shinichiro
    Honbou, Naoto
    Minami, Keiichiro
    ACTA OPHTHALMOLOGICA, 2013, 91 (07) : E546 - E549
  • [40] Effect of corneal asphericity and spherical aberration on intraocular lens power calculations
    Holladay, Jack T.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (07): : 1553 - 1554