Impedance pH Monitoring: Intra-observer and Inter-observer Agreement and Usefulness of a Rapid Analysis of Symptom Reflux Association

被引:0
|
作者
Tenca, Andrea [1 ,2 ]
Campagnola, Pietro [3 ,4 ]
Bravi, Ivana [5 ]
Benini, Luigi [3 ,4 ]
Sifrim, Daniel [5 ]
Penagini, Roberto [1 ,2 ]
机构
[1] Univ Milan, Gastroenterol Unit 2, Milan, Italy
[2] Osped Maggiore Policlin, Fdn IRCCS Ca Granda, I-20122 Milan, Italy
[3] Univ Verona, Gastroenterol Unit, I-37100 Verona, Italy
[4] Policlin GB Rossi, Verona, Italy
[5] Queen Mary Univ London, Barts & London Sch Med & Dent, London, England
关键词
Esophageal pH monitoring; Inter-observer variability; Intra-observer variability; BASE-LINE IMPEDANCE; INTRALUMINAL IMPEDANCE; NORMAL VALUES; THERAPY; VARIABILITY; ACID;
D O I
10.5056/jnm.2014.20.2.205
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background/Aims Symptom reflux association analysis is especially helpful for evaluation and management of proton pump inhibitor (PPI) refractory patients. An accurate calculation requires manual editing of 24-hour multichannel intraluminal impedance-pH (MII-pH) tracings after automatic analysis. Intra- and inter-observer agreement as well as reliability of rapid editing confined to the time around symptomatic episodes are unknown. Aim of this study was to explore these topics in a prospective multicenter study. Methods Forty consecutive patients who were off PPI therapy underwent MII-pH recordings. After automatic analysis, their tracings were anonymized and randomized. Three experienced observers, each one trained in a different European center, independently performed manual editing of 24-hour tracings on 2 separate occasions. Values of symptom index and symptom association probability for acid and non acid reflux were transformed into binary response (i.e., positive or negative). Results Intra-observer agreement on symptom reflux association was 92.5% to 100.0% for acid and 85.0% to 97.5% for non-acid reflux. Inter-observer agreement was 100.0% for acid and 82.5% to 95.0% for non-acid reflux. Values for symptom index and symptom association probability were similar. Concordance between 24-hour and rapid (2 minutes-window before each symptomatic episode) editings for symptom reflux association occured in 39 to 40 patients (acid) and in 37 to 40 (non-acid), depending on the observer. Conclusions Intra- and inter-observer agreement in classifying patients with or without symptom reflux association at manual editing of 24-hour tracings was high, especially for acid reflux. Classifying patients according to a rapid editing showed excellent concordance with the 24-hour one and can be adopted in clinical practice.
引用
收藏
页码:205 / 211
页数:7
相关论文
共 50 条
  • [41] An inter-observer and intra-observer study of a classification of RetCam images of retinal haemorrhages in children
    Mulvihill, Alan O.
    Jones, Patricia
    Tandon, Anamika
    Fleck, Brian W.
    Minns, Robert A.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2011, 95 (01) : 99 - 104
  • [42] Inter-Observer and Intra-Observer Reliability of the Risser Sign in a Metropolitan Scoliosis Screening Program
    Hammond, Kyle E.
    Dierckman, Brian D.
    Burnworth, Laura
    Meehan, Peter L.
    Oswald, Timothy S.
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2011, 31 (08) : E80 - E84
  • [43] Prospective analysis of inter-observer and intra-observer variability in multi ultrasound descriptor assessment of thyroid nodules
    Dobruch-Sobczak, Katarzyna
    Migda, Bartosz
    Krauze, Agnieszka
    Mlosek, Krzysztof
    Slapa, Rafal Z.
    Wareluk, Pawel
    Bakula-Zalewska, Elwira
    Adamczewski, Zbigniew
    Lewinski, Andrzej
    Jakubowski, Wiestaw
    Dedecjus, Marek
    JOURNAL OF ULTRASONOGRAPHY, 2019, 19 (78) : 198 - 206
  • [44] Inter-observer and Intra-observer Agreement in Pathological Evaluation of Non-alcoholic Fatty Liver Disease Suspected Liver Biopsies
    Pournik, Omid
    Alavian, Seyed Moayed
    Ghalichi, Leila
    Seifizarei, Bahram
    Mehrnoush, Leila
    Aslani, Azam
    Anjarani, Soghra
    Eslami, Saeid
    HEPATITIS MONTHLY, 2014, 14 (01)
  • [45] Inter-observer and intra-observer agreement between embryologists during selection of a single Day 5 embryo for transfer: amulticenter study
    Storr, Ashleigh
    Venetis, Christos A.
    Cooke, Simon
    Kilani, Suha
    Ledger, William
    HUMAN REPRODUCTION, 2017, 32 (02) : 307 - 314
  • [46] INTER- AND INTRA-OBSERVER AGREEMENT IN THE MILCH AND WEISS SYSTEMS
    Charles Lozoya, Sergio
    Trevino Baez, Joaquin Dario
    Rangel Flores, Jesus Maria
    Brizuela Ventura, Jesus Miguel
    Araiza Topete, Omar
    Alcazar Juarez, Andrea
    ACTA ORTOPEDICA BRASILEIRA, 2018, 26 (04): : 218 - 221
  • [47] Morphology vs morphokinetics: a retrospective comparison of inter-observer and intra-observer agreement between embryologists on blastocysts with known implantation outcome
    Adolfsson, Emma
    Andershed, Anna Nowosad
    JORNAL BRASILEIRO DE REPRODUCAO ASSISTIDA, 2018, 22 (03): : 228 - 237
  • [48] Inter-observer and intra-observer agreement in the radiographic diagnosis of avascular necrosis of the femoral head following slipped capital femoral epiphysis
    Davidson, Darin
    Ghag, Arvindera
    Beauchamp, Richard D.
    Tredwell, Stephen J.
    Mulpuri, Kishore
    JOURNAL OF CHILDRENS ORTHOPAEDICS, 2010, 4 (04) : 327 - 330
  • [49] Low Inter-Observer Agreement on Nodular Regenerative Hyperplasia of the Liver: An European Inter-Observer Analysis
    Jharap, Bindia
    van Asseldonk, Dirk P.
    de Boer, Nanne K.
    Colombel, Jean-Frederic
    Diebold, Joachim
    Jonker, Anne M.
    Leteurtre, Emmanuelle
    Reinisch, Walter
    Vernier-Massouille, Gwenola
    Wendum, Dominique
    Wrba, Friedrich
    Zondervan, Pieter E.
    Mulder, Chris J. J.
    van Bodegraven, Adriaan A.
    Bloemena, Elisabeth
    GASTROENTEROLOGY, 2010, 138 (05) : S456 - S456
  • [50] Measurement of high resolution ultrasound images: Intra-observer and inter-observer reliablity and image reproducibility
    Bentley, E
    Diehl, KA
    Miller, PE
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U286 - U286