Impedance pH Monitoring: Intra-observer and Inter-observer Agreement and Usefulness of a Rapid Analysis of Symptom Reflux Association

被引:0
|
作者
Tenca, Andrea [1 ,2 ]
Campagnola, Pietro [3 ,4 ]
Bravi, Ivana [5 ]
Benini, Luigi [3 ,4 ]
Sifrim, Daniel [5 ]
Penagini, Roberto [1 ,2 ]
机构
[1] Univ Milan, Gastroenterol Unit 2, Milan, Italy
[2] Osped Maggiore Policlin, Fdn IRCCS Ca Granda, I-20122 Milan, Italy
[3] Univ Verona, Gastroenterol Unit, I-37100 Verona, Italy
[4] Policlin GB Rossi, Verona, Italy
[5] Queen Mary Univ London, Barts & London Sch Med & Dent, London, England
关键词
Esophageal pH monitoring; Inter-observer variability; Intra-observer variability; BASE-LINE IMPEDANCE; INTRALUMINAL IMPEDANCE; NORMAL VALUES; THERAPY; VARIABILITY; ACID;
D O I
10.5056/jnm.2014.20.2.205
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background/Aims Symptom reflux association analysis is especially helpful for evaluation and management of proton pump inhibitor (PPI) refractory patients. An accurate calculation requires manual editing of 24-hour multichannel intraluminal impedance-pH (MII-pH) tracings after automatic analysis. Intra- and inter-observer agreement as well as reliability of rapid editing confined to the time around symptomatic episodes are unknown. Aim of this study was to explore these topics in a prospective multicenter study. Methods Forty consecutive patients who were off PPI therapy underwent MII-pH recordings. After automatic analysis, their tracings were anonymized and randomized. Three experienced observers, each one trained in a different European center, independently performed manual editing of 24-hour tracings on 2 separate occasions. Values of symptom index and symptom association probability for acid and non acid reflux were transformed into binary response (i.e., positive or negative). Results Intra-observer agreement on symptom reflux association was 92.5% to 100.0% for acid and 85.0% to 97.5% for non-acid reflux. Inter-observer agreement was 100.0% for acid and 82.5% to 95.0% for non-acid reflux. Values for symptom index and symptom association probability were similar. Concordance between 24-hour and rapid (2 minutes-window before each symptomatic episode) editings for symptom reflux association occured in 39 to 40 patients (acid) and in 37 to 40 (non-acid), depending on the observer. Conclusions Intra- and inter-observer agreement in classifying patients with or without symptom reflux association at manual editing of 24-hour tracings was high, especially for acid reflux. Classifying patients according to a rapid editing showed excellent concordance with the 24-hour one and can be adopted in clinical practice.
引用
收藏
页码:205 / 211
页数:7
相关论文
共 50 条
  • [21] Inter-Observer and Inter-Analysis Agreement for Impedance Tracing and Color Contours Analysis of Esophageal Impedance Reflux Data
    Luger, Daniel
    Pandolfino, John E.
    Kahrilas, Peter J.
    Kwiatek, Monika A.
    GASTROENTEROLOGY, 2010, 138 (05) : S76 - S76
  • [22] Inter-observer agreement for multichannel intraluminal impedance-pH testing
    Ravi, K.
    DeVault, K. R.
    Murray, J. A.
    Bouras, E. P.
    Francis, D. L.
    DISEASES OF THE ESOPHAGUS, 2010, 23 (07): : 540 - 544
  • [23] Intra-observer and inter-observer agreement of the manual examination of the lumbar spine in chronic low-back pain
    Etienne Qvistgaard
    Jens Rasmussen
    Jes Lætgaard
    Steen Hecksher-Sørensen
    Henning Bliddal
    European Spine Journal, 2007, 16 : 277 - 282
  • [24] Intra-observer and inter-observer agreement of the manual examination of the lumbar spine in chronic low-back pain
    Qvistgaard, Etienne
    Rasmussen, Jens
    Laetgaard, Jes
    Hecksher-Sorensen, Steen
    Bliddal, Henning
    EUROPEAN SPINE JOURNAL, 2007, 16 (02) : 277 - 282
  • [25] INTRA-OBSERVER AND INTER-OBSERVER MEASUREMENT ERROR IN CRANIOMETRY - VONTOROK WOULD NOT BE PLEASED
    ZEGURA, SL
    UTERMOHLE, CJ
    AMERICAN JOURNAL OF PHYSICAL ANTHROPOLOGY, 1982, 57 (02) : 243 - 243
  • [26] Inter-observer reliability and intra-observer reproducibility of the Weber classification of ankle fractures
    Malek, I. A.
    Machani, B.
    Mevcha, A. M.
    Hyder, N. H.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (09): : 1204 - 1206
  • [27] Inter-observer and Intra-observer Reliability for NICE 2017 Interpretation Guidelines for Cardiotopography
    Ghuman, Navdeep Kaur
    Singhmor, Priya
    Singh, Pratibha
    Kathuria, Priyanka
    Sharma, Charu
    OBSTETRICS AND GYNECOLOGY, 2022, 139 : 48S - 49S
  • [28] Intra-observer and inter-observer variation in the histopathological assessment of chronic viral hepatitis
    Goldin, RD
    Goldin, JG
    Burt, AD
    Dhillon, PA
    Hubscher, S
    Wyatt, J
    Patel, N
    JOURNAL OF HEPATOLOGY, 1996, 25 (05) : 649 - 654
  • [29] Inter-observer and intra-observer reliability in the radiographic measurements of paediatric forefoot alignment
    Jasiewicz, Barbara
    Pietraszek, Jacek
    Duda, Slawomir
    Pietrzak, Szymon
    Pruszczynski, Blazej
    Parol, Tomasz
    Potaczek, Tomasz
    Gadek-Moszczak, Aneta
    FOOT AND ANKLE SURGERY, 2021, 27 (04) : 371 - 376
  • [30] How reliable is the pathologist's diagnosis of endometriosis: a prospective inter-observer and intra-observer analysis
    Hurtado, Rodrigo
    Geber, Selmo
    JOURNAL OF ENDOMETRIOSIS AND PELVIC PAIN DISORDERS, 2012, 4 (01) : 30 - 33