Quantification of mycophenolic acid in human plasma by liquid chromatography with time-of-flight mass spectrometry for therapeutic drug monitoring

被引:1
|
作者
Antunes, Natalicia J. [1 ,2 ,3 ]
Ince, Nina [3 ,4 ]
Raymond, Jason [3 ,4 ]
Kipper, Karin [3 ,5 ]
Couchman, Lewis [3 ,6 ]
Holt, David W. [3 ]
De Nucci, Gilberto [1 ]
Johnston, Atholl [2 ,3 ]
机构
[1] Univ Estadual Campinas, Dept Pharmacol, Fac Med Sci, Campinas, SP, Brazil
[2] Queen Mary Univ London, William Harvey Res Inst, Barts & London Sch Med & Dent, Clin Pharmacol, London, England
[3] St Georges Univ London, Analyt Serv Int Ltd, London, England
[4] Univ Surrey, Dept Chem, Guildford, Surrey, England
[5] Univ Tartu, Inst Chem, Tartu, Estonia
[6] Kings Coll London, Pharmaceut Sci Clin Acad Grp, London, England
基金
巴西圣保罗研究基金会;
关键词
immunosuppressant; therapeutic drug monitoring; LC– TOF– MS; mycophenolic acid; TRANSPLANT RECIPIENTS; CLINICAL PHARMACOKINETICS; GLUCURONIDE; IDENTIFICATION; MOFETIL;
D O I
10.1002/bmc.5011
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This study presents, for the first time, the development and validation of a liquid chromatography and time-of-flight mass-spectrometry (LC-TOF-MS) based assay to quantify mycophenolic acid (MPA) in patient samples as part of a routine therapeutic drug monitoring service. MPA was extracted from 50 mu l human plasma by protein precipitation, using sulindac as internal standard (IS). Separation was obtained on a Luna (TM) Omega polar C-18 column kept at 40 degrees C. The mobile phase consisted of a mixture of acetonitrile-deionized water (50:50, v/v) with 0.1% formic acid at a flow rate of 350 mu l/min. Analyte and IS were monitored on a TOF-MS using a Jet-Stream (TM) (electrospray) interface running in positive mode. Assay performance was evaluated by analysing patient plasma (N = 69) and external quality assessment (N = 6) samples. The retention times were 2.66 and 2.18 min for MPA and IS, respectively. The lower limit of quantification of MPA was 0.1 mu g/ml. The within- and between-assay reproducibility results ranged from 1.81 to 10.72%. Patient and external quality assessment sample results were comparable with those obtained previously by an in-house validated LC-MS/MS method. This method showed satisfactory analytical performance for the determination of MPA in plasma over the calibration range of 0.1-15.0 mu g/ml.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Identification of multiple components in Guanxinning injection using hydrophilic interaction liquid chromatography/time-of-flight mass spectrometry and reversed-phase liquid chromatography/time-of-flight mass spectrometry
    Chen, Xiaofei
    Lou, Ziyang
    Zhang, Hai
    Tan, Guangguo
    Liu, Zhirui
    Li, Wuhong
    Zhu, Zhenyu
    Chai, Yifeng
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2011, 25 (11) : 1661 - 1674
  • [32] Dried plasma spot-based liquid chromatography-tandem mass spectrometry for the quantification of methotrexate in human plasma and its application in therapeutic drug monitoring
    Cao, Haiwei
    Li, Li
    Wang, Shaomin
    Guo, Haiyang
    Ren, Wenbo
    Li, Yanyan
    Huang, Jing
    JOURNAL OF SEPARATION SCIENCE, 2022, 45 (06) : 1153 - 1161
  • [33] Combined drug screening and confirmation by liquid chromatography time-of-flight mass spectrometry with reverse database search
    de Castro, Ana
    Gergov, Merja
    Ostman, Pekka
    Ojanpera, Ilkka
    Pelander, Anna
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 403 (05) : 1265 - 1278
  • [34] Combined drug screening and confirmation by liquid chromatography time-of-flight mass spectrometry with reverse database search
    Ana de Castro
    Merja Gergov
    Pekka Östman
    Ilkka Ojanperä
    Anna Pelander
    Analytical and Bioanalytical Chemistry, 2012, 403 : 1265 - 1278
  • [35] Therapeutic drug monitoring of amikacin: quantification in plasma by liquid chromatography-tandem mass spectrometry and work experience of clinical pharmacists
    Xu, Lijie
    Cheng, Xuefang
    Zhu, Guanhua
    Hu, Juanni
    Li, Qin
    Fan, Guorong
    EUROPEAN JOURNAL OF HOSPITAL PHARMACY, 2022, 29 (E1) : e77 - e82
  • [36] Comparison between liquid chromatography-time-of-flight mass spectrometry and selected reaction monitoring liquid chromatography-mass spectrometry for quantitative determination of idoxifene in human plasma
    Zhang, HW
    Henion, J
    JOURNAL OF CHROMATOGRAPHY B, 2001, 757 (01): : 151 - 159
  • [37] Liquid Chromatography Quadrupole Time-of-Flight Mass Spectrometry: A Strategy for Optimization, Characterization, and Quantification of Antioxidant Nitro Derivatives
    Chen, Kitmin
    Edgar, Alexander S.
    Wong, Camille H.
    Yang, Dali
    ACS OMEGA, 2022, 7 (36): : 32701 - 32707
  • [38] Clinical advantage in monitoring mycophenolic acid by liquid chromatography-tandem mass spectrometry
    Brown, Nigel W.
    Pires, Maria S.
    Einarsdottir, Eyrun N.
    Franklin, Michael
    Gonde, Chris E.
    Taylor, Paul J.
    Tredger, J. Michael
    HEPATOLOGY, 2006, 44 (04) : 417A - 417A
  • [39] ANALYTIC VALIDATION OF PETINIA ASSAY FOR THERAPEUTIC DRUG MONITORING OF MYCOPHENOLIC ACID IN KIDNEY TRANSPLANT RECIPIENTS COMPARED WITH LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY
    Kim, Su Hee
    Park, Young-Jae
    Seo, Min Young
    Lee, Sukyung
    Lee, Jong-Hak
    Cho, Sun Young
    Kwon, Eugene
    Jung, Hee-Yeon
    Choi, Ji-Young
    Park, Sun-Hee
    Kim, Yong-Lim
    Kim, Chan-Duck
    Cho, Jang-Hee
    TRANSPLANT INTERNATIONAL, 2015, 28 : 639 - 639
  • [40] Quantification of mycophenolic acid in plasma by isotope dilution liquid chromatography-tandem mass spectrometry candidate reference method
    Lin, Jing
    Shen, Min
    Yu, Ting
    Wang, Huimin
    Pan, Jingjue
    Huang, Gaipeng
    Li, Quanle
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2025, 417 (08) : 1607 - 1617