Comparison between liquid chromatography-time-of-flight mass spectrometry and selected reaction monitoring liquid chromatography-mass spectrometry for quantitative determination of idoxifene in human plasma

被引:30
|
作者
Zhang, HW [1 ]
Henion, J [1 ]
机构
[1] Cornell Univ, New York State Coll Vet Med, Ithaca, NY 14850 USA
来源
JOURNAL OF CHROMATOGRAPHY B | 2001年 / 757卷 / 01期
关键词
iodoxifene;
D O I
10.1016/S0378-4347(01)00132-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This study compares HPLC electrospray time-of-flight mass spectrometry and selected reaction monitoring (SRM) LC-MS for high throughput quantitative determination of a small molecule drug in biological samples. A high throughput LC-MS method was developed for quantitatative determination of idoxifene in human plasma and the evaluation was accomplished with the cross-validation of the developed LC-MS method between the time-of-flight mass spectrometer, and a triple quadrupole mass spectrometer operated in the SRM mode. A simple one-step semi-automated 96-well liquid-liquid extraction procedure was used to prepare 96 samples in approximately 30 min and a rapid gradient was used to shorten the LC run time. Time-of-flight mass spectrometry provides acquisition of full-scan mass spectra and extracted ion current chromatograms, which may be extracted from the total ion current chromatogram for peak area determination. The limit of quantitation for idoxifene in human plasma obtained with the time-of-flight mass spectrometer was 5 ng/ml based on 100-mul aliquots of human plasma, and the linear dynamic range was from 5 ng/ml to 2000 ng/ml. The quantitative LC-MS results from the time-of-flight mass spectrometer demonstrated that precision did not exceed 7.1% and accuracy did not exceed 1.7% with reference to quality control samples at three concentration levels in replicates of six. In contrast, the limit of quantitation for idoxifene in human plasma using a tandem triple quadrupole mass spectrometer was 0.5 ng/ml with a linear dynamic range to 1000 ng/ml. The results from the triple quadrupole instrument show that the precision did not exceed 2.2% and accuracy did not exceed 2.9%. The overall results suggest time-of-flight mass spectrometry may be a viable technique for high throughput bioanalytical work for the quantitative determination of a representative small molecule drug in the low ng/ml range in human plasma. (C) 2001 Elsevier Science BN, All rights reserved.
引用
收藏
页码:151 / 159
页数:9
相关论文
共 50 条
  • [1] Quantitative determination of cefetamet in human plasma by liquid chromatography-mass spectrometry
    Noh, Keumhan
    Kim, Eunyoung
    Kang, Wonku
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2011, 25 (07) : 779 - 782
  • [2] Determination of Simvastatin in human plasma by liquid chromatography-mass spectrometry
    Yang, HT
    Feng, Y
    Luan, YW
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 785 (02): : 369 - 375
  • [3] Quantitative determination of sauchinone in rat plasma by liquid chromatography-mass spectrometry
    Xu, Chun-lei
    Chen, Jian-wei
    Ju, Wen-zheng
    Liu, Shi-jia
    Chen, Yong
    Chen, Zhi-peng
    Xue, Ping
    Chen, Hong-jiang
    Li, Xiang
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2012, 26 (10) : 1210 - 1214
  • [4] Quantitative determination of daumone in rat plasma by liquid chromatography-mass spectrometry
    Noh, Keumhan
    Park, Jung Hyun
    Park, Jong Hee
    Kim, Minkyu
    Jung, Mankil
    Ha, Hunjoo
    Kwon, Kwang-il
    Lee, Hwa Jeong
    Kang, Wonku
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 56 (01) : 114 - 117
  • [5] Comparison of liquid chromatography with fluorescence detection to liquid chromatography-mass spectrometry for the determination of fluoxetine and norfluoxetine in human plasma
    Kovacevic, I
    Miljkovic, B
    Jovanovic, D
    Prostran, M
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 830 (02): : 372 - 376
  • [6] Determination of fexofenadine in human plasma and urine by liquid chromatography-mass spectrometry
    Hofmann, U
    Seiler, M
    Drescher, S
    Fromm, MF
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 766 (02): : 227 - 233
  • [7] Liquid chromatography-mass spectrometry method for the determination of nicardipine in human plasma
    Qi, ML
    Wang, P
    Xin, J
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 830 (01): : 81 - 85
  • [8] Determination of rimonabant in human plasma and hair by liquid chromatography-mass spectrometry
    Delyle, Stanislas Grassin
    Abe, Emuri
    Devillier, Philippe
    Alvarez, Jean Claude
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 872 (1-2): : 115 - 120
  • [9] Quantitative liquid chromatography/time-of-flight mass spectrometry
    Williamson, Leah N.
    Bartlett, Michael G.
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2007, 21 (06) : 567 - 576
  • [10] Quantitative determination of lipase activity by liquid chromatography-mass spectrometry
    Hao, Gang
    Yang, Lan
    Mazsaroff, Istvan
    Lin, Melanie
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2007, 18 (09) : 1579 - 1581