Comparison between liquid chromatography-time-of-flight mass spectrometry and selected reaction monitoring liquid chromatography-mass spectrometry for quantitative determination of idoxifene in human plasma

被引:30
|
作者
Zhang, HW [1 ]
Henion, J [1 ]
机构
[1] Cornell Univ, New York State Coll Vet Med, Ithaca, NY 14850 USA
来源
JOURNAL OF CHROMATOGRAPHY B | 2001年 / 757卷 / 01期
关键词
iodoxifene;
D O I
10.1016/S0378-4347(01)00132-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This study compares HPLC electrospray time-of-flight mass spectrometry and selected reaction monitoring (SRM) LC-MS for high throughput quantitative determination of a small molecule drug in biological samples. A high throughput LC-MS method was developed for quantitatative determination of idoxifene in human plasma and the evaluation was accomplished with the cross-validation of the developed LC-MS method between the time-of-flight mass spectrometer, and a triple quadrupole mass spectrometer operated in the SRM mode. A simple one-step semi-automated 96-well liquid-liquid extraction procedure was used to prepare 96 samples in approximately 30 min and a rapid gradient was used to shorten the LC run time. Time-of-flight mass spectrometry provides acquisition of full-scan mass spectra and extracted ion current chromatograms, which may be extracted from the total ion current chromatogram for peak area determination. The limit of quantitation for idoxifene in human plasma obtained with the time-of-flight mass spectrometer was 5 ng/ml based on 100-mul aliquots of human plasma, and the linear dynamic range was from 5 ng/ml to 2000 ng/ml. The quantitative LC-MS results from the time-of-flight mass spectrometer demonstrated that precision did not exceed 7.1% and accuracy did not exceed 1.7% with reference to quality control samples at three concentration levels in replicates of six. In contrast, the limit of quantitation for idoxifene in human plasma using a tandem triple quadrupole mass spectrometer was 0.5 ng/ml with a linear dynamic range to 1000 ng/ml. The results from the triple quadrupole instrument show that the precision did not exceed 2.2% and accuracy did not exceed 2.9%. The overall results suggest time-of-flight mass spectrometry may be a viable technique for high throughput bioanalytical work for the quantitative determination of a representative small molecule drug in the low ng/ml range in human plasma. (C) 2001 Elsevier Science BN, All rights reserved.
引用
收藏
页码:151 / 159
页数:9
相关论文
共 50 条
  • [31] Identification of fumonisin B2, HT-2 toxin, patulin, and zearalenone in dried figs by liquid chromatography-time-of-flight mass spectrometry and liquid chromatography-mass spectrometry
    Senyuva, H. Z.
    Gilbert, J.
    [J]. JOURNAL OF FOOD PROTECTION, 2008, 71 (07) : 1500 - 1504
  • [32] Systematic forensic toxicological analysis by liquid-chromatography-quadrupole-time-of-flight mass spectrometry in serum and comparison to gas chromatography-mass spectrometry
    Grapp, Marcel
    Kaufmann, Christoph
    Streit, Frank
    Binder, Lutz
    [J]. FORENSIC SCIENCE INTERNATIONAL, 2018, 287 : 63 - 73
  • [33] Liquid chromatography/time-of-flight mass spectrometry
    Wang, A.P.L.
    Guo, X.
    Li, L.
    [J]. Analytical Chemistry, 1994, 66 (21)
  • [34] Liquid Chromatography-Mass Spectrometry Determination of Cetrizine Hydrochloride in Rabbit Plasma
    Chandrasekar, M. J. N.
    Chandrasekar, A. R.
    Krishnaraj, K.
    Muralidharan, S.
    Rajan, S.
    Suresh, B.
    [J]. ASIAN JOURNAL OF CHEMISTRY, 2009, 21 (08) : 5821 - 5828
  • [35] Determination of nandrolone metabolites in human urine: comparison between liquid chromatography/tandem mass spectrometry and gas chromatography/mass spectrometry
    Buiarelli, Francesca
    Giannetti, Luigi
    Jasionowska, Renata
    Cruciani, Claudia
    Neri, Bruno
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2010, 24 (13) : 1881 - 1894
  • [36] Determination of sialic acids by liquid chromatography-mass spectrometry
    Shaw, CJ
    Chao, H
    Xiao, BM
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2001, 913 (1-2) : 365 - 370
  • [37] Quantitative determination of azithromycin in human plasma by liquid chromatography-mass spectrometry and its application in a bioequivalence study
    Chen, Ben-Mei
    Liang, Yi-Zeng
    Chen, Xiang
    Liu, Shao-Gang
    Deng, Fu-Liang
    Zhou, Ping
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2006, 42 (04) : 480 - 487
  • [38] Quantitative determination of pimozide in human plasma by liquid chromatography-mass spectrometry and its application in a bioequivalence study
    Yan, Miao
    Li, Huan-De
    Chen, Ben-Mei
    Liu, Xiao-Lei
    Xu, Ping
    Zhu, Yun-Gui
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2010, 51 (05) : 1161 - 1164
  • [39] Determination and quantitative analysis of designer drugs in human urine by liquid chromatography-mass spectrometry
    Chen, Xueguo
    Zhang, Ting
    [J]. ANALYTICAL METHODS, 2014, 6 (20) : 8291 - 8298
  • [40] Derivatization for liquid chromatography-mass spectrometry
    Qi, Bao-Ling
    Liu, Ping
    Wang, Qiu-Yi
    Cai, Wen-Jing
    Yuan, Bi-Feng
    Feng, Yu-Qi
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2014, 59 : 121 - 132