Calibrated high-precision 17O-excess measurements using cavity ring-down spectroscopy with laser-current-tuned cavity resonance

被引:104
|
作者
Steig, E. J. [1 ,2 ,3 ]
Gkinis, V. [3 ,4 ]
Schauer, A. J. [1 ,2 ]
Schoenemann, S. W. [1 ,2 ]
Samek, K. [1 ,2 ]
Hoffnagle, J. [5 ]
Dennis, K. J. [5 ]
Tan, S. M. [5 ]
机构
[1] Univ Washington, IsoLab, Seattle, WA 98195 USA
[2] Univ Washington, Quaternary Res Ctr, Seattle, WA 98195 USA
[3] Univ Copenhagen, Niels Bohr Inst, Ctr Ice & Climate, DK-2100 Copenhagen, Denmark
[4] Univ Colorado, Inst Arctic & Alpine Res, Boulder, CO 80309 USA
[5] Picarro Inc, Santa Clara, CA 95054 USA
基金
美国国家科学基金会;
关键词
STABLE-ISOTOPE MEASUREMENTS; RATIO MASS-SPECTROMETRY; DEUTERIUM EXCESS; ABSORPTION-SPECTROSCOPY; ENHANCED ABSORPTION; ORGANIC-COMPOUNDS; CARBON-DIOXIDE; WATER SAMPLES; ICE CORE; OXYGEN;
D O I
10.5194/amt-7-2421-2014
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
High-precision analysis of the O-17/O-16 isotope ratio in water and water vapor is of interest in hydrological, paleoclimate, and atmospheric science applications. Of specific interest is the parameter (17)Oexcess (Delta O-17), a measure of the deviation from a linear relationship between O-17/O-16 and O-18/O-16 ratios. Conventional analyses of Delta O-17 of water are obtained by fluorination of H2O to O-2 that is analyzed by dual-inlet isotope ratio mass spectrometry (IRMS). We describe a new laser spectroscopy instrument for high-precision Delta O-17 measurements. The new instrument uses cavity ring-down spectroscopy (CRDS) with laser-current-tuned cavity resonance to achieve reduced measurement drift compared with previous-generation instruments. Liquid water and water-vapor samples can be analyzed with a better than 8 per meg precision for Delta O-17 using integration times of less than 30 min. Calibration with respect to accepted water standards demonstrates that both the precision and the accuracy of Delta O-17 are competitive with conventional IRMS methods. The new instrument also achieves simultaneous analysis of delta O-18, delta O-17 and delta D with precision of < 0.03 parts per thousand, < 0.02 and < 0.2 parts per thousand, respectively, based on repeated calibrated measurements.
引用
收藏
页码:2421 / 2435
页数:15
相关论文
共 50 条
  • [41] Absolute Measurements of Total Peroxy Nitrate Mixing Ratios by Thermal Dissociation Blue Diode Laser Cavity Ring-Down Spectroscopy
    Paul, Dipayan
    Osthoff, Hans D.
    ANALYTICAL CHEMISTRY, 2010, 82 (15) : 6695 - 6703
  • [42] High-resolution cw-diode laser cavity ring-down spectroscopy in hydrogen plasma at room temperature
    Macko, P
    Plasil, R
    Kudrna, P
    Hlavenka, P
    Poterya, V
    Pysanenko, A
    Bánó, G
    Glosík, J
    CZECHOSLOVAK JOURNAL OF PHYSICS, 2002, 52 : 695 - 704
  • [43] Optical extinction efficiency measurements on fine and accumulation mode aerosol using single particle cavity ring-down spectroscopy
    Cotterell, Michael I.
    Mason, Bernard J.
    Preston, Thomas C.
    Orr-Ewing, Andrew J.
    Reid, Jonathan P.
    PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2015, 17 (24) : 15843 - 15856
  • [44] Quantitative measurements of O2 b←X(2,1,0←0) bands by using cavity ring-down spectroscopy
    Xu, SC
    Dai, DX
    Xie, JC
    Sha, GH
    Zhang, CH
    CHEMICAL PHYSICS LETTERS, 1999, 303 (1-2) : 171 - 175
  • [45] Observation of C2 radicals formed by laser ablation of graphite targets using cavity ring-down spectroscopy
    Labazan, I
    Krstulovic, N
    Milosevic, S
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2003, 36 (20) : 2465 - 2470
  • [46] Time-resolved measurements of NO2 concentration in pulsed discharges by high-sensitivity cavity ring-down spectroscopy
    吴兴伟
    李聪
    冯春雷
    王奇
    丁洪斌
    PlasmaScienceandTechnology, 2017, 19 (05) : 84 - 88
  • [47] Time-resolved measurements of NO2 concentration in pulsed discharges by high-sensitivity cavity ring-down spectroscopy
    Wu, Xingwei
    Li, Cong
    Feng, Chunlei
    Wang, Qi
    Ding, Hongbin
    PLASMA SCIENCE & TECHNOLOGY, 2017, 19 (05)
  • [48] Cavity ring-down spectroscopy sensor development for high-time-resolution measurements of gaseous elemental mercury in ambient air
    Pierce, A.
    Obrist, D.
    Moosmueller, H.
    Fain, X.
    Moore, C.
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2013, 6 (06) : 1477 - 1489
  • [49] High-resolution cavity ring-down absorption spectroscopy of nitrous oxide and chloroform using a near-infrared cw diode laser
    He, YB
    Hippler, M
    Quack, M
    CHEMICAL PHYSICS LETTERS, 1998, 289 (5-6) : 527 - 534
  • [50] Cavity ring-down spectroscopy of H218O in the range 16 570-17 120 cm-1
    Tanaka, M
    Sneep, M
    Ubachs, W
    Tennyson, J
    JOURNAL OF MOLECULAR SPECTROSCOPY, 2004, 226 (01) : 1 - 6