High-resolution cw-diode laser cavity ring-down spectroscopy in hydrogen plasma at room temperature

被引:0
|
作者
Macko, P
Plasil, R
Kudrna, P
Hlavenka, P
Poterya, V
Pysanenko, A
Bánó, G
Glosík, J
机构
[1] Charles Univ Prague, Fac Math & Phys, Dept Elect & Vacuum Phys, CR-18000 Prague 8, Czech Republic
[2] Comenius Univ, Fac Math Phys & Informat, Dept Plasma Phys, Bratislava 84248, Slovakia
[3] Hungarian Acad Sci, Res Inst Solid State Phys & Opt, H-1121 Budapest, Hungary
关键词
Hh3+; laser spectroscopy;
D O I
暂无
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Reported is a description of an infrared cavity ring-down (CRD) spectrometer employing a cw-diode laser, that is applied for absorption measurements in a microwave discharge. The apparatus was recently built for study of recombination of H-3(+)(v = 0) with electrons. In cavity ring-down spectroscopy (CRDS) the monochromatic light of the laser is coupled into an optical cavity composed of high-reflectivity mirrors. Interrupting the laser beam the light intensity within the cavity decays due to losses on the mirrors and also due to absorbtion by gas-phase molecules (and/or molecular ions). The characteristic time constant of the exponential decay is coupled with the absorption coefficient, which is given by the corresponding absorption cross section and by the density of absorbing species. Using the CRDS method the absolute density of H-3(+) ions in hydrogen containing plasma is determined. The sensibility of the new CRDS system (< 2 x 10(-8) cm(-1)) was found to be sufficient for this kind of measurements.
引用
收藏
页码:695 / 704
页数:10
相关论文
共 50 条
  • [1] High-resolution cavity ring-down absorption spectroscopy of nitrous oxide and chloroform using a near-infrared cw diode laser
    He, YB
    Hippler, M
    Quack, M
    CHEMICAL PHYSICS LETTERS, 1998, 289 (5-6) : 527 - 534
  • [2] Afterglow studies of H3+(v=0) recombination using time resolved cw-diode laser cavity ring-down spectroscopy
    Macko, P
    Bán, G
    Hlavenka, P
    Plasil, R
    Poterya, V
    Pysanenko, A
    Votava, O
    Johnsen, R
    Glosík, J
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2004, 233 (1-3) : 299 - 304
  • [3] CW-cavity ring-down spectroscopy with cavity feedback-injection seeding lock of diode laser
    Oh, Myoung-Kyu
    Lee, Yonghoon
    Choi, Sung-Chul
    2009 LASERS & ELECTRO-OPTICS & THE PACIFIC RIM CONFERENCE ON LASERS AND ELECTRO-OPTICS, VOLS 1 AND 2, 2009, : 1123 - 1124
  • [4] Cavity ring-down spectroscopy with diode array
    Nikolaev, Igor V.
    Ochkin, Vladimir N.
    Spiridonov, Maxim V.
    Tskhai, Sergei N.
    15TH SYMPOSIUM ON HIGH-RESOLUTION MOLECULAR SPECTROSCOPY, 2006, 6580
  • [5] Trace gas analysis by diode laser cavity ring-down spectroscopy
    Yan, WB
    LEOS 2001: 14TH ANNUAL MEETING OF THE IEEE LASERS & ELECTRO-OPTICS SOCIETY, VOLS 1 AND 2, PROCEEDINGS, 2001, : 873 - 874
  • [6] Trace gas analysis by diode laser cavity ring-down spectroscopy
    Yan, WB
    TEST AND MEASUREMENT APPLICATIONS OF OPTOELECTRONIC DEVICES, 2002, 4648 : 156 - 164
  • [7] Trace gas analysis by diode laser cavity ring-down spectroscopy
    Yan, WB
    Krusen, C
    Optics, T
    Dudek, J
    Lehmann, K
    Rabinowitz, P
    2002 IEEE/SEMI ADVANCED SEMICONDUCTOR MANUFACTURING CONFERENCE AND WORKSHOP: ADVANCING THE SCIENCE OF SEMICONDUCTOR MANUFACTURING EXCELLENCE, 2002, : 319 - 323
  • [8] Trace gas detection with CW cavity ring-down laser absorption spectroscopy
    Yan, WB
    Dudek, J
    Lehmann, K
    Rabinowitz, P
    2000 IEEE/SEMI ADVANCED SEMICONDUCTOR MANUFACTURING CONFERENCE AND WORKSHOP, 2000, : 203 - 206
  • [9] Diode laser cavity ring-down spectroscopy for atmospheric NO2 measurement
    Hu R.
    Wang D.
    Xie P.
    Chen H.
    Ling L.
    Guangxue Xuebao/Acta Optica Sinica, 2016, 36 (02):
  • [10] Room-Temperature Cavity Ring-Down Spectroscopy of Methylallyl Peroxy Radicals
    Reza, Md Asmaul
    Telfah, Hamzeh
    Xu, Raobo
    Liu, Jinjun
    JOURNAL OF PHYSICAL CHEMISTRY A, 2019, 123 (16): : 3510 - 3517