Estimation of the noise-contributions from blank, transmission and emission scans in PET

被引:12
|
作者
Holm, S [1 ]
Toft, P [1 ]
Jensen, M [1 ]
机构
[1] TECH UNIV DENMARK,DEPT MATH MODELLING,LYNGBY,DENMARK
关键词
D O I
10.1109/23.531893
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This work determines the relative importance of noise from blank (B), transmission (T) and emission (E) scans in PET using a GE Advance scanner on a 20 cm cylinder, a brain phantom, and a torso-like ellipse (18/35 cm) with examples of human scans (brain O-15 water and F-18 FDG, heart FDG). Phantom E scans were acquired in both 2D and 3D modes as decay series with C-11 or F-18 over 3-6 decades of Noise Equivalent Counts (NEC). B and T scans were made using two pin sources (approximate to 500 MBq total) over 64-32768 sec. In humans only a Limited subset was available. In homogeneous phantoms normalized variance (var) was estimated from pixel distributions in single images. In other objects, including the human studies, calculations were performed on differences of paired images. In all cases a fit was made to a simple noise model. The cylinder data show expected relations of T to B noise proving the adequacy of B scan times less than or equal to 20 min for most purposes. For the brain phantom, a contour plot is provided for var(E,T). In a typical 3D O-15 water study with 0.5M counts per central slice, a 10 min T-scan adds less than 10% to the total noise level. An example shows how to split a total scan time between E and T scans, in order to minimize the variance.
引用
收藏
页码:2285 / 2291
页数:7
相关论文
共 42 条
  • [1] Estimation of the noise contributions from blank, transmission and emission scans in PET
    Holm, S
    Toft, P
    Jensen, M
    [J]. 1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 1470 - 1474
  • [2] Joint estimation of attenuation and emission images from PET scans
    Erdogan, H
    Fessler, JA
    [J]. 1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 1672 - 1675
  • [3] VALIDATION OF SIMULTANEOUS PET EMISSION AND TRANSMISSION SCANS
    THOMPSON, CJ
    RANGER, N
    EVANS, AC
    GJEDDE, A
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1991, 32 (01) : 154 - 160
  • [4] The derivation of detector efficiencies in PET from single photon blank scans
    Hogg, D
    Thielemans, K
    Spinks, TJ
    [J]. 2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 2206 - 2209
  • [5] SIMULTANEOUS EMISSION AND TRANSMISSION SCANS IN PET USING A MASKED ORBITING TRANSMISSION SOURCE (MOTS)
    THOMPSON, CJ
    RANGER, NT
    EVANS, AC
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1989, 30 (10) : 1751 - 1751
  • [6] MISALIGNMENT BETWEEN PET TRANSMISSION AND EMISSION SCANS - EFFECT ON MYOCARDIAL IMAGING
    TERPOGOSSIAN, MM
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1992, 33 (06) : 1214 - 1215
  • [7] Statistical image reconstruction methods for simultaneous emission/transmission PET scans
    Erdogan, H
    Fessler, JA
    [J]. 1996 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1997, : 1579 - 1583
  • [8] MISALIGNMENT BETWEEN PET TRANSMISSION AND EMISSION SCANS - ITS EFFECT ON MYOCARDIAL IMAGING
    MCCORD, ME
    BACHARACH, SL
    BONOW, RO
    DILSIZIAN, V
    CUOCOLO, A
    FREEDMAN, N
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1992, 33 (06) : 1209 - 1214
  • [9] Randoms from Singles Estimation for Long PET Scans
    Stearns, Charles W.
    Lonn, Albert H. R.
    [J]. 2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3739 - 3741
  • [10] Penalized-likelihood estimators and noise analysis for randoms-precorrected PET transmission scans
    Yavuz, M
    Fessler, JA
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1999, 18 (08) : 665 - 674