Estimation of the noise-contributions from blank, transmission and emission scans in PET

被引:12
|
作者
Holm, S [1 ]
Toft, P [1 ]
Jensen, M [1 ]
机构
[1] TECH UNIV DENMARK,DEPT MATH MODELLING,LYNGBY,DENMARK
关键词
D O I
10.1109/23.531893
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This work determines the relative importance of noise from blank (B), transmission (T) and emission (E) scans in PET using a GE Advance scanner on a 20 cm cylinder, a brain phantom, and a torso-like ellipse (18/35 cm) with examples of human scans (brain O-15 water and F-18 FDG, heart FDG). Phantom E scans were acquired in both 2D and 3D modes as decay series with C-11 or F-18 over 3-6 decades of Noise Equivalent Counts (NEC). B and T scans were made using two pin sources (approximate to 500 MBq total) over 64-32768 sec. In humans only a Limited subset was available. In homogeneous phantoms normalized variance (var) was estimated from pixel distributions in single images. In other objects, including the human studies, calculations were performed on differences of paired images. In all cases a fit was made to a simple noise model. The cylinder data show expected relations of T to B noise proving the adequacy of B scan times less than or equal to 20 min for most purposes. For the brain phantom, a contour plot is provided for var(E,T). In a typical 3D O-15 water study with 0.5M counts per central slice, a 10 min T-scan adds less than 10% to the total noise level. An example shows how to split a total scan time between E and T scans, in order to minimize the variance.
引用
收藏
页码:2285 / 2291
页数:7
相关论文
共 42 条
  • [11] Simultaneous post-injection transmission and emission contamination scans in a volume imaging PET scanner
    Smith, RJ
    Karp, JS
    [J]. 1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 1781 - 1785
  • [12] Alignment of transmission and emission scans of PET to correct for subject movement using a sinogram consistency criterion
    Yu, CL
    Huang, SC
    Dahlbom, M
    Bergsneider, M
    [J]. 2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 2889 - 2892
  • [13] Simultaneous emission and transmission scanning in PET oncology: Effect on parameter estimation
    Meikle, SR
    Eberl, S
    Hooper, PK
    Fulham, MJ
    [J]. 1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 1368 - 1372
  • [14] Simultaneous emission and transmission scanning in PET oncology: The effect on parameter estimation
    Meikle, SR
    Eberl, S
    Hooper, PK
    Fulham, MJ
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (01) : 67 - 73
  • [15] Noise and Sharpness estimation in Positron Emission Tomography (PET) images using radiomics and deep learning
    Bharathi, P. Gurunath
    Moradi, F.
    Khalighi, M.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (SUPPL 1) : S348 - S348
  • [16] An effective reconstruction algorithm of attenuation map from post-injection PET transmission scans
    Chang, MY
    Hsu, CH
    Hsiao, IT
    Kao, PF
    [J]. 2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 2826 - 2830
  • [17] Segmentation-free direct tumor volume and metabolic activity estimation from PET scans
    Taghanaki, Saeid Asgari
    Duggan, Noirin
    Ma, Hillgan
    Hou, Xinchi
    Celler, Anna
    Benard, Francois
    Hamarneh, Ghassan
    [J]. COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2018, 63 : 52 - 66
  • [18] Post-injection transmission scans in a PET camera operating without septa with simultaneous measurement of emission activity contamination.
    Smith, RJ
    Karp, JS
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (04) : 2207 - 2212
  • [19] Impact of a mismatch between the spatial resolution of the emission and transmission scans on the standardized uptake values (SUV) measured in FDG PET.
    Soret, M
    Feuardent, J
    Hapdey, S
    Buvat, I
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2002, 43 (05) : 13P - 13P
  • [20] The effect of transmission scan duration and smoothing on the accuracy of PET emission scans using both filtered backprojection and iterative reconstruction.
    Boellaard, R
    van Lingen, A
    van Loon, M
    van Balen, S
    Hoving, B
    Lammertsma, A
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (05) : 298P - 298P