摘要
We developed a means of calculating detector efficiencies from blank transmission scan measurements that use a single photon source. The method is based on a new measurement model that shows how the detector efficiencies contribute to the recorded measurement. Two different approaches to calculate efficiencies are given, where one is based on the Maximum Likelihood principle. By way of example, blanks acquired from an EYACT3D scanner are processed using these methods. The calculated sets of efficiencies from the two methods are shown to be similar to each other. The variation in the blank caused by detector efficiency is shown to match very well the measurement model when these estimated efficiencies are used. The first application of our approach has been to perform a daily detector check, removing the necessity for a phantom.
引用
收藏
页码:2206 / 2209
页数:4
相关论文
共 50 条
  • [1] Calculation of single detector efficiencies and extension of the normalization sinogram in PET
    Hermansen, F
    Spinks, TJ
    Camici, PG
    Lammertsma, AA
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (06): : 1143 - 1154
  • [2] Estimation of the noise contributions from blank, transmission and emission scans in PET
    Holm, S
    Toft, P
    Jensen, M
    [J]. 1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 1470 - 1474
  • [3] Influence of malfunctioning block detectors on the calculation of single detector efficiencies in PET
    Ferreira, NC
    Trébossen, R
    Grégoire, MC
    Bendriem, B
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (04) : 1062 - 1069
  • [4] Estimation of the noise-contributions from blank, transmission and emission scans in PET
    Holm, S
    Toft, P
    Jensen, M
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (04) : 2285 - 2291
  • [5] Quantitative analysis of PET blank scans in the windows environment.
    Kemp, BJ
    Zent, GW
    Porter, DV
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (05) : 250P - 250P
  • [6] Derivation of generalized quantum jump operators and comparison of the microscopic single photon detector models
    T. Häyrynen
    J. Oksanen
    J. Tulkki
    [J]. The European Physical Journal D, 2010, 56 : 113 - 121
  • [7] Derivation of generalized quantum jump operators and comparison of the microscopic single photon detector models
    Hayrynen, T.
    Oksanen, J.
    Tulkki, J.
    [J]. EUROPEAN PHYSICAL JOURNAL D, 2010, 56 (01): : 113 - 121
  • [8] The SiPM - A new photon detector for PET
    Otte, N
    Dolgoshein, B
    Hose, J
    Klemin, S
    Lorenz, E
    Mirzoyan, R
    Popova, E
    Teshima, M
    [J]. NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2006, 150 : 417 - 420
  • [9] SINGLE-PHOTON DETECTOR Free from polarization
    Won, Rachel
    [J]. NATURE PHOTONICS, 2008, 2 (12) : 719 - 719
  • [10] Performing volume imaging PET scans in the presence of high residual single photon activity.
    Smith, RJ
    Karp, JS
    Benard, F
    Alavi, A
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (05) : 852 - 852