A high sensitivity 4π view gamma imager with a monolithic 3D position-sensitive detector

被引:10
|
作者
Ye, Qing [1 ,2 ]
Fan, Peng [3 ,4 ]
Wang, Rui [1 ,2 ]
Lyu, Zhenlei [1 ,2 ]
Hu, Ankang [1 ,2 ]
Wei, Qingyang [5 ]
Xia, Yan [3 ,4 ]
Yao, Rutao [6 ]
Liu, Yaqiang [1 ,2 ]
Ma, Tianyu [1 ,2 ]
机构
[1] Tsinghua Univ, Dept Engn Phys, Beijing 100084, Peoples R China
[2] Tsinghua Univ, Key Lab Particle & Radiat Imaging, Minist Educ, Beijing 100084, Peoples R China
[3] China Acad Space Technol, Beijing Inst Spacecraft Environm Engn, Beijing 100094, Peoples R China
[4] Beijing Inst Spacecraft Environm Engn, Sci & Technol Reliabil & Environm Engn Lab, Beijing 100094, Peoples R China
[5] Univ Sci & Technol Beijing, Beijing Engn Res Ctr Ind Spectrum Imaging, Sch Automat & Elect Engn, Beijing 100083, Peoples R China
[6] Univ Buffalo State Univ New York, Dept Nucl Med, Buffalo, NY 14214 USA
基金
国家重点研发计划; 中国国家自然科学基金;
关键词
Nuclear security; Gamma imager; Image reconstruction; Monolithic detector; NEURAL-NETWORK; DEPTH; DESIGN; LOCALIZATION; SIMULATION; EMISSION;
D O I
10.1016/j.nima.2019.05.022
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Imaging is an effective way to survey gamma radiation hotspots in nuclear safety, public health and homeland security applications. The existing gamma imagers either equip a collimator, which limits the imaging field of view (FOV) and sensitivity, or work without a collimator but require a high performance detector with sophisticated data processing and image reconstruction methods, e.g. the Compton camera. In this work, we demonstrate the feasibility of a high sensitivity 4 pi view gamma imager design concept. Based on the photon event density distribution inside a monolithic 3D position-sensitive detector, the imager reconstructs the 4 pi view of the surrounding gamma hotspots that the detector is exposed to. Monte Carlo simulations and experiments were conducted for several configurations of surrounding sparse gamma point sources in the energy range from 0.1 to 1.5 MeV. The results show that the reconstructed 4 pi view image can identify multiple gamma hotspots, with the hotspots' positioning accuracy and resolution dependent on the detector's intrinsic resolution and the statistics of the acquired data. We conclude that the proposed design can be used for surveying gamma hotspots in nuclear security applications.
引用
收藏
页码:31 / 40
页数:10
相关论文
共 50 条
  • [41] GAMMA-RAY POSITION-SENSITIVE COAXIAL GE(LI) DETECTOR
    SHERMAN, IS
    STRAUSS, MG
    NUCLEAR INSTRUMENTS & METHODS, 1974, 117 (01): : 285 - 294
  • [42] POSITION-SENSITIVE LIQUID-XENON DETECTOR FOR gamma RAYS.
    Gushchin, E.M.
    Kruglov, A.A.
    Obodovskii, I.M.
    Pokachalov, S.G.
    Shilov, V.A.
    Instruments and experimental techniques New York, 1982, 25 (3 pt 1): : 561 - 564
  • [43] Absolute Gamma Source Positioning with Position-sensitive Scintillation Detector Arrays
    Wang, Rui
    Wang, Shi
    Fan, Peng
    Xu, Tianpeng
    Lyu, Zhenlei
    Ye, Qing
    Wu, Zhaoxia
    Xia, Yan
    Liu, Yaqiang
    Ma, Tianyu
    2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,
  • [44] OPTIMIZATION OF LIGHT YIELD OF SCINTILLATOR FOR POSITION-SENSITIVE GAMMA-DETECTOR
    VOLKOVICH, AG
    LIKSONOV, VI
    LOBANOVSKII, DA
    SMIRNOV, SV
    STEPANOV, VE
    TYURIN, AS
    URUTSKOEV, LI
    FILIPPOV, DV
    CHESNOKOV, AV
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1991, 34 (02) : 325 - 327
  • [45] Positional correction of a 3D position-sensitive virtual Frisch-grid CZT detector for gamma spectroscopy and imaging based on a theoretical assumption
    Kim, Younghak
    Shin, Kichang
    Bolotnikov, Aleksey
    Lee, Wonho
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2023, 55 (05) : 1718 - 1733
  • [46] 4π Compton imaging with single 3D position sensitive CdZnTe detector
    Xu, D
    He, Z
    Lehner, CE
    Zhang, F
    HARD X-RAY AND GAMMA-RAY DETECTOR PHYSICS VI, 2004, 5540 : 144 - 155
  • [47] REDUCTION OF THE ELECTRONICS OF A 1D POSITION-SENSITIVE DETECTOR
    DUIJN, JH
    VANEIJK, CWE
    HOLLANDER, RW
    SLOOF, GW
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 273 (2-3): : 541 - 543
  • [48] REDUCTION OF THE ELECTRONICS OF A 1D POSITION-SENSITIVE DETECTOR
    DUIJN, JH
    VANEIJK, CWE
    HOLLANDER, RW
    SLOOF, GW
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1988, 35 (01) : 135 - 137
  • [49] 2-D POSITION-SENSITIVE SCINTILLATION DETECTOR FOR NEUTRONS
    STRAUSS, MG
    BRENNER, R
    LYNCH, FJ
    MORGAN, CB
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1981, 28 (01) : 800 - 806
  • [50] 2-D scintillation position-sensitive neutron detector
    De Lurgio, Patrick M.
    Farrar, Kelly A.
    Kreps, Andrew S.
    Madden, Timothy J.
    Naday, Istvan
    Weizeorick, John T.
    Hammonds, John P.
    Miller, Martha E.
    Schultz, Arthur J.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 648 - 653