A high sensitivity 4π view gamma imager with a monolithic 3D position-sensitive detector

被引:10
|
作者
Ye, Qing [1 ,2 ]
Fan, Peng [3 ,4 ]
Wang, Rui [1 ,2 ]
Lyu, Zhenlei [1 ,2 ]
Hu, Ankang [1 ,2 ]
Wei, Qingyang [5 ]
Xia, Yan [3 ,4 ]
Yao, Rutao [6 ]
Liu, Yaqiang [1 ,2 ]
Ma, Tianyu [1 ,2 ]
机构
[1] Tsinghua Univ, Dept Engn Phys, Beijing 100084, Peoples R China
[2] Tsinghua Univ, Key Lab Particle & Radiat Imaging, Minist Educ, Beijing 100084, Peoples R China
[3] China Acad Space Technol, Beijing Inst Spacecraft Environm Engn, Beijing 100094, Peoples R China
[4] Beijing Inst Spacecraft Environm Engn, Sci & Technol Reliabil & Environm Engn Lab, Beijing 100094, Peoples R China
[5] Univ Sci & Technol Beijing, Beijing Engn Res Ctr Ind Spectrum Imaging, Sch Automat & Elect Engn, Beijing 100083, Peoples R China
[6] Univ Buffalo State Univ New York, Dept Nucl Med, Buffalo, NY 14214 USA
基金
国家重点研发计划; 中国国家自然科学基金;
关键词
Nuclear security; Gamma imager; Image reconstruction; Monolithic detector; NEURAL-NETWORK; DEPTH; DESIGN; LOCALIZATION; SIMULATION; EMISSION;
D O I
10.1016/j.nima.2019.05.022
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Imaging is an effective way to survey gamma radiation hotspots in nuclear safety, public health and homeland security applications. The existing gamma imagers either equip a collimator, which limits the imaging field of view (FOV) and sensitivity, or work without a collimator but require a high performance detector with sophisticated data processing and image reconstruction methods, e.g. the Compton camera. In this work, we demonstrate the feasibility of a high sensitivity 4 pi view gamma imager design concept. Based on the photon event density distribution inside a monolithic 3D position-sensitive detector, the imager reconstructs the 4 pi view of the surrounding gamma hotspots that the detector is exposed to. Monte Carlo simulations and experiments were conducted for several configurations of surrounding sparse gamma point sources in the energy range from 0.1 to 1.5 MeV. The results show that the reconstructed 4 pi view image can identify multiple gamma hotspots, with the hotspots' positioning accuracy and resolution dependent on the detector's intrinsic resolution and the statistics of the acquired data. We conclude that the proposed design can be used for surveying gamma hotspots in nuclear security applications.
引用
收藏
页码:31 / 40
页数:10
相关论文
共 50 条
  • [21] Preliminary results of a Compton camera based on a single 3D position-sensitive CZT detector
    Liu, Yi-Lin
    Fu, Jian-Qiang
    Li, Yu-Lan
    Li, Yuan-Jing
    Ma, Xu-Ming
    Zhang, Lan
    NUCLEAR SCIENCE AND TECHNIQUES, 2018, 29 (10)
  • [22] Multi-channel front-end ASIC for a 3D position-sensitive detector
    Pinaroli, G.
    Herrmann, S.
    Miryala, S.
    Manthena, V.
    Deptuch, G. W.
    Carini, G. A.
    Bolotnikov, A. E.
    Dellapenna, A.
    Raguzin, E.
    Fried, J.
    Deane, C. R.
    Brown, C. A.
    Christian, J.
    Cirignano, L.
    Kargar, A.
    Kim, H.
    Shah, K. S.
    Squillante, M.
    Squillante, M. S.
    Weststrate, E.
    Valente, A. J.
    Koslowsky, M. R.
    Miller, A. L.
    Smith, M. B.
    JOURNAL OF INSTRUMENTATION, 2022, 17 (02):
  • [23] Preliminary results of a Compton camera based on a single 3D position-sensitive CZT detector
    Yi-Lin Liu
    Jian-Qiang Fu
    Yu-Lan Li
    Yuan-Jing Li
    Xu-Ming Ma
    Lan Zhang
    Nuclear Science and Techniques, 2018, 29
  • [24] A POSITION-SENSITIVE GERMANIUM DETECTOR FOR GAMMA-RAY ASTRONOMY
    VARNELL, LS
    LING, JC
    MAHONEY, WA
    JACOBSON, AS
    PEHL, RH
    GOULDING, FS
    LANDIS, DA
    LUKE, PN
    MADDEN, NW
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1984, 31 (01) : 300 - 306
  • [25] Position-sensitive compressed-xenon electroluminescent gamma detector
    Egorov, V.V.
    Instruments and experimental techniques New York, 1988, 31 (1 pt 1): : 53 - 56
  • [26] A POSITION-SENSITIVE DETECTOR FOR A GAMMA-RAY IMAGING TELESCOPE
    CARTER, JN
    CHARALAMBOUS, P
    DEAN, AJ
    STEPHEN, JB
    BUTLER, RC
    DICOCCO, G
    MORELLI, E
    SPADA, G
    SPIZZICHINO, A
    BARBARESCHI, L
    BOELLA, G
    PEROTTI, F
    VILLA, G
    BADIALI, M
    LAPADULA, C
    POLCARO, F
    UBERTINI, P
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1982, 196 (2-3): : 477 - 482
  • [27] NEW SETUP FOR A POSITION-SENSITIVE GAMMA-RAY DETECTOR
    ASPACHER, B
    MAIER, K
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1994, 65 (04): : 857 - 860
  • [28] A HIGH-RESOLUTION GAMMA-CAMERA BASED ON A MULTIWIRE POSITION-SENSITIVE DETECTOR
    ANISIMOV, YS
    CHEREMUKHINA, GA
    CHERNENKO, SP
    IVANOV, AB
    MATYUSHEVSKY, EA
    MOVCHAN, SA
    NETUSHILOVA, Z
    PESHEKHONOV, VD
    ZANEVSKY, YV
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1985, 235 (03): : 582 - 588
  • [29] Estimation of Compton imager using single 3D position-sensitive LYSO scintillator: Monte Carlo simulation
    Taewoong Lee
    Hyounggun Lee
    Younghak Kim
    Wonho Lee
    Journal of the Korean Physical Society, 2017, 71 : 70 - 76
  • [30] Estimation of Compton Imager Using Single 3D Position-Sensitive LYSO Scintillator: Monte Carlo Simulation
    Lee, Taewoong
    Lee, Hyounggun
    Kim, Younghak
    Lee, Wonho
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2017, 71 (02) : 70 - 76