Novel approach for anterior chamber angle analysis - Anterior chamber angle detection with edge measurement and identification algorithm (ACADEMIA)

被引:26
|
作者
Leung, Christopher Kai-shun [1 ]
Yung, Wing-ho
Yiu, Cedric Ka-fai
Lam, Sze-wing
Leung, Dexter Yu-lung
Tse, Raymond Kwok-kay
Tham, Clement Chi-yung
Chan, Wai-man
Lam, Dennis Shun-chiu
机构
[1] Chinese Univ Hong Kong, Fac Med, Dept Ophthalmol & Visual Sci, Hong Kong, Hong Kong, Peoples R China
[2] Chinese Univ Hong Kong, Fac Med, Caritas Med Ctr, Hong Kong, Hong Kong, Peoples R China
[3] Chinese Univ Hong Kong, Fac Med, Dept Physiol, Hong Kong, Hong Kong, Peoples R China
[4] Univ Hong Kong, Dept Ind & Mfg Syst Engn, Hong Kong, Hong Kong, Peoples R China
[5] Prince Wales Hosp, Dept Ophthalmol, Hong Kong, Hong Kong, Peoples R China
关键词
D O I
10.1001/archopht.124.10.1395
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: To describe a novel approach to measuring anterior chamber angle dimensions and configurations. Methods: Sixty-nine images were selected randomly from the ultrasound biomicroscopic image database to develop the algorithm. Thirty images were selected for further analyses. The value of each pixel of the 8-bit grayscale ultrasound biomicroscopic images was quantized into 0 (black) or 1 (white), and the edge points outlining the angle were detected and fitted with straight lines. The dimensions and profiles of anterior chamber angles were then measured. Results: The algorithm failed to identify the edge points correctly in 8 (11.6%) of 69 images because of strong background noise. Three basic types of angle configuration were identified based on the derived angle profiles: constant, increasing, and decreasing, which corresponded to flat, bowed forward, and bowed backward iris contours, respectively. The angle measurements demonstrated high correlation with trabecular-iris angle and angle opening distance 500 (calculated as the distance from the corneal endothelium to the anterior iris surface perpendicular to a line drawn at 500 mu m from the scleral spur). The strongest association was found between the averaged angle derived from the angle profile and the angle opening distance 500 (r = 0.91). Conclusion: The proposed algorithm has high correlations with angle opening distance and trabecular-iris angle with the added advantages of being fully automated, reproducible, and able to capture the characteristic angle configurations. However, good-quality ultrasound biomicroscopic images with high signal-to-noise ratio are required to identify the edge points correctly.
引用
收藏
页码:1395 / 1401
页数:7
相关论文
共 50 条
  • [1] Pathologies of the anterior chamber angle
    Vass, Clemens
    [J]. ACTA OPHTHALMOLOGICA, 2024, 102
  • [2] DEVELOPMENT OF ANGLE OF ANTERIOR CHAMBER
    WORST, JGF
    [J]. OPHTHALMOLOGICA, 1968, 155 (04) : 330 - &
  • [3] ANTERIOR CHAMBER ANGLE RECESS
    DELANEY, WV
    KANTER, AI
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 1970, 69 (06) : 1016 - &
  • [4] ANATOMY OF THE ANGLE OF THE ANTERIOR CHAMBER
    KARA, GB
    [J]. ARCHIVES OF OPHTHALMOLOGY, 1957, 58 (02) : 306 - 307
  • [5] THE ANTERIOR-CHAMBER ANGLE ANALYSIS MYOPIA
    LIN, SY
    YANG, CH
    HUANG, JK
    SHIH, YF
    LIN, LLK
    HUNG, PT
    [J]. VISION RESEARCH, 1995, 35 : P311 - P311
  • [6] Ultrasound biomicroscopic measurement of development of anterior chamber angle
    Kobayashi, H
    Ono, H
    Kiryu, J
    Kobayashi, K
    Kondo, T
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 1999, 83 (05) : 559 - 562
  • [7] Automated Analysis of Angle Closure From Anterior Chamber Angle Images
    Baskaran, Mani
    Cheng, Jun
    Perera, Shamira A.
    Tun, Tin A.
    Liu, Jiang
    Aung, Tin
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (11) : 7669 - 7673
  • [8] EMBRYOLOGICAL DEVELOPMENT OF THE ANGLE OF THE ANTERIOR CHAMBER
    KORNZWEIG, AL
    [J]. ARCHIVES OF OPHTHALMOLOGY, 1957, 58 (02) : 305 - 306
  • [9] Mucopolysaccharidosis with Narrow Anterior Chamber Angle
    Varshney, Toshit
    Mahalingam, Karthikeyan
    Gupta, Shikha
    [J]. OPHTHALMOLOGY GLAUCOMA, 2022, 5 (01): : 100 - 100
  • [10] A NOTE ON DEVELOPMENT OF ANTERIOR CHAMBER ANGLE
    KUPFER, C
    [J]. INVESTIGATIVE OPHTHALMOLOGY, 1969, 8 (01): : 69 - &