Novel approach for anterior chamber angle analysis - Anterior chamber angle detection with edge measurement and identification algorithm (ACADEMIA)

被引:26
|
作者
Leung, Christopher Kai-shun [1 ]
Yung, Wing-ho
Yiu, Cedric Ka-fai
Lam, Sze-wing
Leung, Dexter Yu-lung
Tse, Raymond Kwok-kay
Tham, Clement Chi-yung
Chan, Wai-man
Lam, Dennis Shun-chiu
机构
[1] Chinese Univ Hong Kong, Fac Med, Dept Ophthalmol & Visual Sci, Hong Kong, Hong Kong, Peoples R China
[2] Chinese Univ Hong Kong, Fac Med, Caritas Med Ctr, Hong Kong, Hong Kong, Peoples R China
[3] Chinese Univ Hong Kong, Fac Med, Dept Physiol, Hong Kong, Hong Kong, Peoples R China
[4] Univ Hong Kong, Dept Ind & Mfg Syst Engn, Hong Kong, Hong Kong, Peoples R China
[5] Prince Wales Hosp, Dept Ophthalmol, Hong Kong, Hong Kong, Peoples R China
关键词
D O I
10.1001/archopht.124.10.1395
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: To describe a novel approach to measuring anterior chamber angle dimensions and configurations. Methods: Sixty-nine images were selected randomly from the ultrasound biomicroscopic image database to develop the algorithm. Thirty images were selected for further analyses. The value of each pixel of the 8-bit grayscale ultrasound biomicroscopic images was quantized into 0 (black) or 1 (white), and the edge points outlining the angle were detected and fitted with straight lines. The dimensions and profiles of anterior chamber angles were then measured. Results: The algorithm failed to identify the edge points correctly in 8 (11.6%) of 69 images because of strong background noise. Three basic types of angle configuration were identified based on the derived angle profiles: constant, increasing, and decreasing, which corresponded to flat, bowed forward, and bowed backward iris contours, respectively. The angle measurements demonstrated high correlation with trabecular-iris angle and angle opening distance 500 (calculated as the distance from the corneal endothelium to the anterior iris surface perpendicular to a line drawn at 500 mu m from the scleral spur). The strongest association was found between the averaged angle derived from the angle profile and the angle opening distance 500 (r = 0.91). Conclusion: The proposed algorithm has high correlations with angle opening distance and trabecular-iris angle with the added advantages of being fully automated, reproducible, and able to capture the characteristic angle configurations. However, good-quality ultrasound biomicroscopic images with high signal-to-noise ratio are required to identify the edge points correctly.
引用
收藏
页码:1395 / 1401
页数:7
相关论文
共 50 条
  • [31] ANTERIOR-CHAMBER ANGLE IN THE EXFOLIATION SYNDROME
    WISHART, PK
    SPAETH, GL
    PORYZEES, EM
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 1985, 69 (02) : 103 - 107
  • [32] Use of EyeCam for Imaging the Anterior Chamber Angle
    Perera, Shamira A.
    Baskaran, Mani
    Friedman, David S.
    Tun, Tin A.
    Htoon, Hla M.
    Kumar, Rajesh S.
    Aung, Tin
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (06) : 2993 - 2997
  • [33] ANTERIOR CHAMBER ANGLE AND OCULAR HYDRODYNAMICS IN APHAKIA
    KHASANOV.NK
    SIDORENK.EI
    [J]. VESTNIK OFTALMOLOGII, 1974, (04) : 27 - 30
  • [34] Foreign Body Embedded in Anterior Chamber Angle
    Graffi, Shmuel
    Tiosano, Beatrice
    Ben Cnaan, Ran
    Bahir, Jonathan
    Naftali, Modi
    [J]. CASE REPORTS IN OPHTHALMOLOGICAL MEDICINE, 2012, 2012
  • [35] ANTERIOR-CHAMBER ANGLE IN THE EXFOLIATION SYNDROME
    BARTHOLOMEW, RS
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 1985, 69 (10) : 795 - 795
  • [36] GLYCOSAMINOGLYCANS AND THE ANTERIOR-CHAMBER ANGLE STRUCTURES
    KNEPPER, PA
    FARBMAN, AI
    TELSER, AG
    [J]. JOURNAL OF CELL BIOLOGY, 1980, 87 (02): : A128 - A128
  • [37] PATHOLOGY OF THE ANGLE OF THE ANTERIOR CHAMBER IN PRIMARY GLAUCOMA
    KORNZWEIG, AL
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 1956, 42 (01) : 137 - 138
  • [38] Observation of Anterior Chamber Angle in Chinese——An Analysis of 224 eyes
    Yang Shu mei et al
    [J]. 黑龙江医药科学, 1985, (01) : 63 - 63
  • [39] ANALYSIS OF THE ANTERIOR-CHAMBER ANGLE BY GONIOSCOPY AND BY ULTRASOUND BIOMICROSCOPY
    RILEY, SF
    NAIRN, JP
    MAESTRE, FA
    SMITH, TJ
    [J]. INTERNATIONAL OPHTHALMOLOGY CLINICS, 1994, 34 (03) : 271 - 282
  • [40] Ultrasound biomicroscopic analysis of the effect of pilocarpine on the anterior chamber angle
    Kobayashi, H
    Kobayashi, K
    Kiryu, J
    Kondo, T
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 1997, 235 (07) : 425 - 430