Automated Analysis of Angle Closure From Anterior Chamber Angle Images

被引:10
|
作者
Baskaran, Mani [1 ,2 ,3 ,4 ]
Cheng, Jun [5 ]
Perera, Shamira A. [1 ,2 ]
Tun, Tin A. [1 ,2 ]
Liu, Jiang [5 ]
Aung, Tin [1 ,2 ,3 ,4 ]
机构
[1] Singapore Eye Res Inst, Singapore, Singapore
[2] Singapore Natl Eye Ctr, Singapore 168751, Singapore
[3] Natl Univ Singapore, Yong Loo Lin Sch Med, Singapore 117595, Singapore
[4] Duke NUS Grad Med Sch, Singapore, Singapore
[5] Inst Infocomm Res, Singapore, Singapore
基金
英国医学研究理事会;
关键词
anterior chamber angle; gonioscopy; EyeCam; angle closure; automated grading; GLAUCOMA; EYECAM;
D O I
10.1167/iovs.14-14852
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To evaluate a novel software capable of automatically grading angle closure on EyeCam angle images in comparison with manual grading of images, with gonioscopy as the reference standard. METHODS. In this hospital-based, prospective study, subjects underwent gonioscopy by a single observer, and EyeCam imaging by a different operator. The anterior chamber angle in a quadrant was classified as closed if the posterior trabecular meshwork could not be seen. An eye was classified as having angle closure if there were two or more quadrants of closure. Automated grading of the angle images was performed using customized software. Agreement between the methods was ascertained by kappa statistic and comparison of area under receiver operating characteristic curves (AUC). RESULTS. One hundred forty subjects (140 eyes) were included, most of whom were Chinese (102/140, 72.9%) and women (72/140, 51.5%). Angle closure was detected in 61 eyes (43.6%) with gonioscopy in comparison with 59 eyes (42.1%, P = 0.73) using manual grading, and 67 eyes (47.9%, P = 0.24) with automated grading of EyeCam images. The agreement for angle closure diagnosis between gonioscopy and both manual (kappa = 0.88; 95% confidence interval [CI), 0.81-0.96) and automated grading of EyeCam images was good (j = 0.74; 95% CI, 0.63-0.85). The AUC for detecting eyes with gonioscopic angle closure was comparable for manual and automated grading (AUC 0.974 vs. 0.954, P = 0.31) of EyeCam images. CONCLUSIONS. Customized software for automated grading of EyeCam angle images was found to have good agreement with gonioscopy. Human observation of the EyeCam images may still be needed to avoid gross misclassification, especially in eyes with extensive angle closure.
引用
收藏
页码:7669 / 7673
页数:5
相关论文
共 50 条
  • [2] Evaluation of blotchy pigments in the anterior chamber angle as a sign of angle closure
    Rao, Harsha L.
    Mungale, Sachin C.
    Kumbar, Tukaram
    Parikh, Rajul S.
    Garudadri, Chandra S.
    [J]. INDIAN JOURNAL OF OPHTHALMOLOGY, 2012, 60 (06) : 535 - 539
  • [3] Automated Anterior Chamber Angle Localization and Glaucoma Type Classification in OCT Images
    Xu, Yanwu
    Liu, Jiang
    Cheng, Jun
    Lee, Beng Hai
    Wong, Damon Wing Kee
    Mani, Baskaran
    Perera, Shamira
    Aung, Tin
    [J]. 2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 7380 - 7383
  • [4] Influence of Anterior Segment Biometric Parameters on the Anterior Chamber Angle Width in Eyes with Angle Closure and Open Angle
    Matsuki, Takaaki
    Hirose, Fumitaka
    Kameda, Takanori
    Hirami, Yasuhiko
    Kurimoto, Yasuo
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [5] Influence of Anterior Segment Biometric Parameters on the Anterior Chamber Angle Width in Eyes With Angle Closure
    Matsuki, Takaaki
    Hirose, Fumitaka
    Ito, Shin-ichiro
    Hata, Masayuki
    Hirami, Yasuhiko
    Kurimoto, Yasuo
    [J]. JOURNAL OF GLAUCOMA, 2015, 24 (02) : 144 - 148
  • [6] Progressive Changes in the Anterior Segment and Their Impact on the Anterior Chamber Angle in Primary Angle Closure Disease
    Kwak, Jiehoon
    Shon, Kilhwan
    Lee, Yunhan
    Sung, Kyung Rim
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2024, 257 : 57 - 65
  • [7] CHRONIC ANGLE-CLOSURE GLAUCOMA MANAGEMENT BY RECONSTRUCTION OF THE ANTERIOR CHAMBER ANGLE
    K.P.Takhchidi
    D.I.Ivanov
    N.V.Strenev
    [J]. 国际眼科杂志, 2003, (01) : 51 - 51
  • [8] Narrowing of the anterior chamber angle during Valsalva maneuver: a possible mechanism for angle closure
    Sihota, R
    Dada, T
    Gupta, V
    Deepak, KK
    Pandey, RM
    [J]. EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2006, 16 (01) : 81 - 91
  • [9] Vitreous Zonule and its Relation to Anterior Chamber Angle Characteristics in Primary Angle Closure
    Shon, Kilhwan
    Sung, Kyung Rim
    Kwon, Junki
    Jo, Youn Hye
    [J]. JOURNAL OF GLAUCOMA, 2019, 28 (12) : 1048 - 1053
  • [10] An unltrasound biomicroscopic study of the effects of brimonidine on the anterior chamber angle in patients with angle closure
    See, JLS
    Gazzard, G
    Chew, PT
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U777 - U777