Comparison of superparamagnetic iron oxide-enhanced and gadobenate dimeglumine-enhanced dynamic MRI for detection of small hepatocellular carcinomas

被引:36
|
作者
Kim, YK
Kim, CS
Lee, YH
Kwak, HS
Lee, JM
机构
[1] Seoul Natl Univ Hosp, Dept Radiol, Seoul 110744, South Korea
[2] Chonbuk Natl Univ Hosp, Dept Diagnost Radiol, Conju, South Korea
[3] Wonkwang Univ, Sch Med, Dept Diagnost Radiol, Iksan, South Korea
[4] Korean Keyryong Army Hosp, Dept Diagnost Radiol, Taejon, South Korea
关键词
D O I
10.2214/ajr.182.5.1821217
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
xOBJECTIVE. The purpose of this study was to compare superparamagnetic iron oxide (SPIO)-enhanced MRI with gadobenate dimeglumine-enhanced MRI for the detection of hepatocellular carcinoma using receiver operating characteristic (ROC) analysis. MATERIALS AND METHODS. Twenty-nine consecutive patients with 35 hepatocellular carcinomas underwent gadobenate dimeglumine-enhanced MRI (unenhanced, arterial, portal, and equilibrium phases) using 3D fat-saturated volumetric interpolated imaging and SPIO-enhanced MRI on a 1.5-T unit. SPIO-enhanced T2-weighted turbo spin-echo and T2*-weighted gradient-echo sequences were performed 48 hr after completion of the dynamic study. Three observers independently interpreted the images in random order, separately, and without patient identifiers. Diagnostic accuracy was evaluated using the alternative free response receiver operating characteristic method. Sensitivity and positive predictive value were also evaluated. RESULTS. The mean sensitivity and positive predictive value of SPIO-enhanced imaging were 81.0% and 85.0%, respectively, and those of gadobenate dimeglumine-enhanced MRI were 91.4% and 88.1%, respectively. A significant difference was seen in the sensitivity of the two MRI examinations (p < 0.05). The mean value of the area under the ROC curve (A(z)) for gadobenate dimeglumine-enhanced imaging (A(z) = 0.97 ± 0.01) was significantly higher than that for SPIO-enhanced imaging (Az = 0.90 ± 0.02) (p = 0.004). CONCLUSION. Gadobenate dimeglumine-enhanced 3D dynamic imaging showed better diagnostic performance than SPIO-enhanced imaging for the detection of hepatocellular carcinomas.
引用
收藏
页码:1217 / 1223
页数:7
相关论文
共 50 条
  • [21] Hepatocellular carcinoma: Evaluation with dynamic and static gadobenate dimeglumine-enhanced MR imaging and histopathologic correlation
    Vogl, TJ
    Stupavsky, A
    Pegios, W
    Hammerstingl, R
    Mack, M
    Diebold, T
    Lodemann, KP
    Neuhaus, P
    Felix, R
    RADIOLOGY, 1997, 205 (03) : 721 - 728
  • [22] Gadobenate dimeglumine-enhanced MRI of intraductal papillary mucinous tumor of the bile ducts
    Park, Mi-Suk
    Yu, Jeong-Sik
    Lee, Dong Ki
    Yoon, Dong-Sup
    Cha, Seung-Whan
    Kim, Ki Whang
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 25 (03) : 625 - 627
  • [23] Intraindividual crossover comparison of gadobenate dimeglumine-enhanced and gadoxetate disodium-enhanced MRI for characterizing focal liver lesions
    Tang, Wenjie
    Xiao, Yuanqiang
    Kuang, Sichi
    Rong, Dailin
    He, Bingjun
    Grazioli, Luigi
    Hussain, Shahid M.
    Wang, Jin
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2025, 9 (01)
  • [24] Three-dimensional dynamic liver MR imaging using sensitivity encoding for detection of hepatocellular carcinomas: Comparison with superparamagnetic iron oxide-enhanced MR imaging
    Kim, YK
    Kim, CS
    Kwak, HS
    Lee, JM
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 20 (05) : 826 - 837
  • [25] Detection of liver metastases on gadobenate dimeglumine-enhanced MRI: systematic review, meta-analysis, and similarities with gadoxetate-enhanced MRI
    Ling Zhang
    Xian Yu
    Lei Huo
    Lun Lu
    Xinpeng Pan
    Ningyang Jia
    Xinxiang Fan
    Giovanni Morana
    Luigi Grazioli
    Guenther Schneider
    European Radiology, 2019, 29 : 5205 - 5216
  • [26] Detection of liver metastases on gadobenate dimeglumine-enhanced MRI: systematic review, meta-analysis, and similarities with gadoxetate-enhanced MRI
    Zhang, Ling
    Yu, Xian
    Huo, Lei
    Lu, Lun
    Pan, Xinpeng
    Jia, Ningyang
    Fan, Xinxiang
    Morana, Giovanni
    Grazioli, Luigi
    Schneider, Guenther
    EUROPEAN RADIOLOGY, 2019, 29 (10) : 5205 - 5216
  • [27] Superparamagnetic iron oxide-enhanced MRI (SPIO-MRI): Optimal pulse sequences for hepatocellular carcinoma detection in cirrhotic patients
    Pacella, CM
    Bizzarri, G
    Anelli, V
    Bianchini, A
    Di Lella, GM
    Valle, D
    RADIOLOGY, 1998, 209P : 374 - 374
  • [28] Gadobenate Dimeglumine-Enhanced Liver MRI: Value of Dynamic and Delayed Imaging for Evaluation of Hepatocellular Carcinoma Tumor Response Following Transarterial Chemoembolization
    Chu, L.
    Bonekamp, S.
    Jolepalem, P.
    Mensa, M.
    Geschwind, J.
    Kamel, I.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (05)
  • [29] Dynamic contrast-enhanced MRI perfusion quantification in hepatocellular carcinoma: comparison of gadoxetate disodium and gadobenate dimeglumine
    Daniel Stocker
    Stefanie Hectors
    Octavia Bane
    Naik Vietti-Violi
    Daniela Said
    Paul Kennedy
    Jordan Cuevas
    Guilherme M. Cunha
    Claude B. Sirlin
    Kathryn J. Fowler
    Sara Lewis
    Bachir Taouli
    European Radiology, 2021, 31 : 9306 - 9315
  • [30] Site-specific ultrasmall superparamagnetic iron oxide-enhanced MRI detection of prostate cancer
    Cai, Quan-Yu
    Yang, Ming
    Xu, Hang
    Yu, Ping
    Hoffman, Timothy
    Ma, Lixin