Comparison of superparamagnetic iron oxide-enhanced and gadobenate dimeglumine-enhanced dynamic MRI for detection of small hepatocellular carcinomas

被引:36
|
作者
Kim, YK
Kim, CS
Lee, YH
Kwak, HS
Lee, JM
机构
[1] Seoul Natl Univ Hosp, Dept Radiol, Seoul 110744, South Korea
[2] Chonbuk Natl Univ Hosp, Dept Diagnost Radiol, Conju, South Korea
[3] Wonkwang Univ, Sch Med, Dept Diagnost Radiol, Iksan, South Korea
[4] Korean Keyryong Army Hosp, Dept Diagnost Radiol, Taejon, South Korea
关键词
D O I
10.2214/ajr.182.5.1821217
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
xOBJECTIVE. The purpose of this study was to compare superparamagnetic iron oxide (SPIO)-enhanced MRI with gadobenate dimeglumine-enhanced MRI for the detection of hepatocellular carcinoma using receiver operating characteristic (ROC) analysis. MATERIALS AND METHODS. Twenty-nine consecutive patients with 35 hepatocellular carcinomas underwent gadobenate dimeglumine-enhanced MRI (unenhanced, arterial, portal, and equilibrium phases) using 3D fat-saturated volumetric interpolated imaging and SPIO-enhanced MRI on a 1.5-T unit. SPIO-enhanced T2-weighted turbo spin-echo and T2*-weighted gradient-echo sequences were performed 48 hr after completion of the dynamic study. Three observers independently interpreted the images in random order, separately, and without patient identifiers. Diagnostic accuracy was evaluated using the alternative free response receiver operating characteristic method. Sensitivity and positive predictive value were also evaluated. RESULTS. The mean sensitivity and positive predictive value of SPIO-enhanced imaging were 81.0% and 85.0%, respectively, and those of gadobenate dimeglumine-enhanced MRI were 91.4% and 88.1%, respectively. A significant difference was seen in the sensitivity of the two MRI examinations (p < 0.05). The mean value of the area under the ROC curve (A(z)) for gadobenate dimeglumine-enhanced imaging (A(z) = 0.97 ± 0.01) was significantly higher than that for SPIO-enhanced imaging (Az = 0.90 ± 0.02) (p = 0.004). CONCLUSION. Gadobenate dimeglumine-enhanced 3D dynamic imaging showed better diagnostic performance than SPIO-enhanced imaging for the detection of hepatocellular carcinomas.
引用
收藏
页码:1217 / 1223
页数:7
相关论文
共 50 条
  • [11] Preoperative prediction of pathologic grade of HCC on gadobenate dimeglumine-enhanced dynamic MRI
    Rong, Dailin
    Liu, Weimin
    Kuang, Sichi
    Xie, Sidong
    Chen, Zhanhong
    Chen, Feifei
    Xie, Qianwei
    Luo, Qiuxia
    He, Bingjun
    Zhang, Yao
    Deng, Ying
    Yang, Hao
    Chen, Simin
    Wang, Jin
    EUROPEAN RADIOLOGY, 2021, 31 (10) : 7584 - 7593
  • [12] Preoperative prediction of pathologic grade of HCC on gadobenate dimeglumine-enhanced dynamic MRI
    Dailin Rong
    Weimin Liu
    Sichi Kuang
    Sidong Xie
    Zhanhong Chen
    Feifei Chen
    Qianwei Xie
    Qiuxia Luo
    Bingjun He
    Yao Zhang
    Ying Deng
    Hao Yang
    Simin Chen
    Jin Wang
    European Radiology, 2021, 31 : 7584 - 7593
  • [13] Does Breast Parenchyma Density Affect the Detection of Malignant Lesions on Gadobenate Dimeglumine-Enhanced MRI Compared to Gadopentetate Dimeglumine-Enhanced MRI, Mammography, and Ultrasound?
    Zechmann, C.
    Martincich, L.
    Faivre-Pierret, M.
    Corcione, S.
    van den Bosch, H.
    Gilbert, F.
    Pediconi, F.
    Sardanelli, F.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (05)
  • [14] Small hypervascular hepatocellular carcinomas: value of “washout” on gadolinium-enhanced dynamic MR imaging compared to superparamagnetic iron oxide-enhanced imaging
    Jeong-Sik Yu
    Jae-Joon Chung
    Joo Hee Kim
    Ki Whang Kim
    European Radiology, 2009, 19 : 2614 - 2622
  • [15] Small hypervascular hepatocellular carcinomas: value of "washout" on gadolinium-enhanced dynamic MR imaging compared to superparamagnetic iron oxide-enhanced imaging
    Yu, Jeong-Sik
    Chung, Jae-Joon
    Kim, Joo Hee
    Kim, Ki Whang
    EUROPEAN RADIOLOGY, 2009, 19 (11) : 2614 - 2622
  • [16] Effect of superparamagnetic iron oxide-enhanced MRI of the liver with hepatocellular carcinoma and hyperplastic nodule
    Takeshita, K
    Nagashima, I
    Frui, S
    Takada, K
    Yamauchi, T
    Harasawa, A
    Oba, H
    Kohtake, H
    Tanaka, H
    Suzuki, S
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2002, 26 (03) : 451 - 455
  • [17] Detection of small hypervascular hepatocellular carcinomas in cirrhotic patients: Comparison of superparamagnetic iron oxide-enhanced MR imaging with dual-phase spiral CT
    Lee, JM
    Kim, IH
    Kwak, HS
    Youk, JH
    Han, YM
    Kim, CS
    KOREAN JOURNAL OF RADIOLOGY, 2003, 4 (01) : 1 - 8
  • [18] Low-dose gadobenate dimeglumine-enhanced MRI in the detection and characterization of focal liver lesions
    Kirchin, MA
    Spinazzi, A
    ACADEMIC RADIOLOGY, 2002, 9 : S121 - S126
  • [19] Detection of liver metastases: Comparison of gadobenate dimeglumine-enhanced and ferumoxides-enhanced MR imaging examinations
    Del Frate, C
    Bazzocchi, M
    Mortele, KJ
    Zuiani, C
    Londero, V
    Como, G
    Zanardi, R
    Ros, PR
    RADIOLOGY, 2002, 225 (03) : 766 - 772
  • [20] Focal Eosinophilic Necrosis on Superparamagnetic Iron Oxide-Enhanced MRI
    Cho, Eun-Suk
    Yu, Jeong-Sik
    Kim, Myeong-Jin
    Kim, Joo Hee
    Chung, Jae-Joon
    Kim, Ki Whang
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (05) : 1296 - 1302