Post-analytical errors with portable glucose meters in the hospital setting

被引:25
|
作者
Carraro, Paolo [1 ]
Plebani, Mario [1 ]
机构
[1] Univ Hosp Padova, Dept Lab Med, Padua, Italy
关键词
Point-of-care testing; Glucose meters; Post-analytical phase; Transcription errors; Patient record; Adverse events; MONITORING BLOOD-GLUCOSE; QUALITY;
D O I
10.1016/j.cca.2009.03.013
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Point-of-care testing (POCT) for blood glucose is widely used in different clinical settings and. thanks to its rapid turnaround time (TAT), it is commonly recommended in patients with critical conditions calling for urgent monitoring. However data in the literature on its reliability and safety are scarce. The aim of the present study was therefore to investigate the type. frequency and clinical risks associated with POCT using portable glucose meters in the hospital setting by evaluating the post-analytical phase when the data are manually transcribed in patients record. We checked all registrations performed by nurses of 2 selected wards of the hospital during a period of 30 consecutive days, identifying 1966 blood glucose determinations. We found that data obtained were often not reported in patients' files (12.1% of results are missed), the time of blood sampling was recorded in imprecise manner in 7.2% of cases and the glucose concentration was incorrectly reported in 3.2% of results. Although in the post-analytical phase the frequency of incomplete or incorrect data was high, no adverse events were found to be related to this type of error. (c) 2009 Elsevier B.V. All rights reserved
引用
收藏
页码:65 / 67
页数:3
相关论文
共 50 条
  • [41] Evaluation of two portable meters for blood glucose measurements in dogs
    Bluwol, K.
    Duarte, R.
    Lustoza, M. D.
    Simoes, D. M. N.
    Kogika, M. M.
    [J]. ARQUIVO BRASILEIRO DE MEDICINA VETERINARIA E ZOOTECNIA, 2007, 59 (06) : 1408 - 1411
  • [42] Assessment of five portable blood glucose meters for use in cats
    Wess, G
    Reusch, C
    [J]. AMERICAN JOURNAL OF VETERINARY RESEARCH, 2000, 61 (12) : 1587 - 1592
  • [43] Evaluation of five portable blood glucose meters for use in dogs
    Wess, G
    Reusch, C
    [J]. JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 2000, 216 (02): : 203 - 209
  • [44] Evaluation of portable blood glucose meters. Problems and recommendations
    Slingerland, RJ
    Miedema, K
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2003, 41 (09) : 1220 - 1223
  • [45] Comparison of Accuracy Guidelines for Hospital Glucose Meters
    Bowman, Cynthia Foss
    Nichols, James H.
    [J]. JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2020, 14 (03): : 546 - 552
  • [46] Evaluation of glucose meters for hospital use.
    Hortin, GL
    Utz, C
    Upton, K
    [J]. CLINICAL CHEMISTRY, 1996, 42 (06) : 262 - 262
  • [47] The circle of circles. Hegel's post-analytical theory of knowledge
    Schick, F
    [J]. ZEITSCHRIFT FUR PHILOSOPHISCHE FORSCHUNG, 2002, 56 (01): : 149 - 151
  • [48] Post-Analytical Methods for Using Data Proceedings for Defense of Collective Systems
    O. V. Syuntyurenko
    [J]. Scientific and Technical Information Processing, 2020, 47 : 29 - 35
  • [49] Post-Analytical Methods for Using Data Proceedings for Defense of Collective Systems
    Syuntyurenko, O. V.
    [J]. SCIENTIFIC AND TECHNICAL INFORMATION PROCESSING, 2020, 47 (01) : 29 - 35
  • [50] Stability of lactate dehydrogenase in plasma at different temperatures: post-analytical storage
    Lopez, Marta Gomez
    Roca, Neila Rodriguez
    Velasco, Manuela Simon
    Martin, Maria Jose Alcaide
    Soto, Antonio Buno
    Rioja, Ruben Gomez
    [J]. ADVANCES IN LABORATORY MEDICINE-AVANCES EN MEDICINA DE LABORATORIO, 2020, 1 (04):