Tracking 3-D coronary artery motion with biplane angiography

被引:0
|
作者
Zhu, H [1 ]
Friedman, MH [1 ]
机构
[1] Duke Univ, Dept Biomed Engn, Durham, NC 27708 USA
关键词
3-D vessel tracking; biplane angiography; 3-D deformable model; block matching; coronary artery;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The motion of coronary arteries has attracted increasing attention because of its possible effects on the development of atherosclerosis. Biplane angiography is the best clinical modality so far to extract this information spatially and temporally. In this paper, a new method is proposed, to track 3-D coronary artery segments in biplane angiogram sequences based on a 3-D deformable model. The model combines the 3-D active contour model with image block matching technique, and considers both global and local motion of the vessel. By this new method, the coronary artery segment can be tracked well over a cardiac cycle.
引用
收藏
页码:605 / 608
页数:4
相关论文
共 50 条
  • [1] 3D reconstruction of coronary artery using biplane angiography
    Law, AKW
    Zhu, H
    Chan, FHY
    [J]. PROCEEDINGS OF THE 25TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: A NEW BEGINNING FOR HUMAN HEALTH, 2003, 25 : 533 - 536
  • [2] Automated unification of 3-D coronary artery trees from biplane angiography with 3-D left ventricles from perfusion SPECT.
    Feber, TL
    Garcia, EV
    Klein, JL
    Folks, RD
    Malveaux, EJ
    Peifer, JW
    Cooke, CD
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1996, 37 (05): : 380 - 380
  • [3] Quantification of 3-D coronary arterial motion using clinical biplane cineangiograms
    Zhaohua Ding
    Morton H. Friedman
    [J]. The International Journal of Cardiac Imaging, 2000, 16 : 331 - 346
  • [4] Quantification of 3-D coronary arterial motion using clinical biplane cineangiograms
    Ding, ZH
    Friedman, MH
    [J]. INTERNATIONAL JOURNAL OF CARDIAC IMAGING, 2000, 16 (05): : 331 - 346
  • [5] Velocity of coronary artery motion during the cardiac cycle: measurement by biplane coronary angiography
    Achenbach, S
    Pohle, K
    Ropers, D
    von Korn, H
    Ludwig, J
    Moshage, W
    Daniel, WG
    [J]. EUROPEAN HEART JOURNAL, 2002, 23 : 66 - 66
  • [6] Accurate 3-D reconstruction of tortuous coronary vessels using biplane angiography and intravascular ultrasound
    Prause, GPM
    DeJong, SC
    McKay, CR
    Sonka, M
    [J]. PHYSIOLOGY AND FUNCTION FROM MULTIDIMENSIONAL IMAGES - MEDICAL IMAGING 1997, 1997, 3033 : 225 - 234
  • [7] Characterization of 3-D Coronary Tree Motion From MSCT Angiography
    Yang, Guanyu
    Zhou, Jian
    Boulmier, Dominique
    Garcia, Marie-Paule
    Luo, Limin
    Toumoulin, Christine
    [J]. IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2010, 14 (01): : 101 - 106
  • [8] Geometrically correct 3-D reconstruction of coronary wall and plaque: Combining biplane angiography and intravascular ultrasound
    Prause, GPM
    DeJong, SC
    McKay, CR
    Sonka, M
    [J]. COMPUTERS IN CARDIOLOGY 1996, 1996, : 325 - 328
  • [9] Optimal polyline tracking for artery motion compensation in coronary angiography
    Dubuisson-Jolly, MP
    Liang, CC
    Gupta, A
    [J]. SIXTH INTERNATIONAL CONFERENCE ON COMPUTER VISION, 1998, : 414 - 419
  • [10] Automatic 3-D tubular centerline tracking of coronary arteries in coronary computed tomographic angiography
    Salehi, Nasrin
    Naghsh-Nilchi, Ahmad Reza
    [J]. COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING-IMAGING AND VISUALIZATION, 2018, 6 (02): : 170 - 181