Optimal polyline tracking for artery motion compensation in coronary angiography

被引:15
|
作者
Dubuisson-Jolly, MP [1 ]
Liang, CC [1 ]
Gupta, A [1 ]
机构
[1] Siemens AG, Corp Res, Princeton, NJ 08540 USA
关键词
D O I
10.1109/ICCV.1998.710752
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
We propose a novel solution to the problem of motion compensation of coronary angiographs. As the heart is beating, it is difficult for the physician to observe closely a particular point (e.g. stenosis) on the artery tree. We propose to rigidly compensate the sequence so that the area around the point of interest appears stable. This is a difficult problem because the arteries deform in a nonrigid manner and only their 2D X-ray projection is observed. Also, the lack of features around the selected point makes the matching subject to the aperture problem. The algorithm automatically extracts a section of the artery of interest, models it as a polyline, and tracks it. The problem is formulated as an energy minimization problem which is solved using a shortest path in a graph algorithm. The motion compensated sequence can be obtained by translating every pixel so that the point of interest remains stable. We have applied this algorithm to many examples in two sets of angiography data and have obtained excellent results.
引用
收藏
页码:414 / 419
页数:6
相关论文
共 50 条
  • [1] Tracking 3-D coronary artery motion with biplane angiography
    Zhu, H
    Friedman, MH
    [J]. 2002 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING, PROCEEDINGS, 2002, : 605 - 608
  • [2] Coronary MR Angiography in patients with coronary artery disease using image-based respiratory motion compensation
    Markus Henningsson
    Konstantinos Bratis
    Eike Nagel
    Rene Botnar
    [J]. Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)
  • [3] Advanced Respiratory Motion Compensation for Coronary MR Angiography
    Henningsson, Markus
    Botnar, Rene M.
    [J]. SENSORS, 2013, 13 (06) : 6882 - 6899
  • [4] Image-based coronary tracking and beat-to-beat motion compensation: Feasibility for improving coronary MR angiography
    Dewan, Maneesh
    Hager, Gregory D.
    Lorenz, Christine H.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (03) : 604 - 615
  • [5] Motion Compensation using Polyline based Block Partition
    Zhang, Yixiong
    Wang, Weidong
    Zheng, Lingxiang
    Wu, Meixuan
    [J]. PROCEEDINGS OF THE 2009 2ND INTERNATIONAL CONGRESS ON IMAGE AND SIGNAL PROCESSING, VOLS 1-9, 2009, : 290 - +
  • [6] Coronary artery motion compensation in spiral CT
    Dallas, WJ
    Ovitt, TW
    [J]. Medical Imaging 2005: Image Processing, Pt 1-3, 2005, 5747 : 2136 - 2147
  • [7] Coronary Artery Motion Estimation and Compensation: a Feasibility Study
    Iatrou, Maria
    Pack, Jed D.
    Bhagalia, Roshni
    Beque, Dirk
    Seamans, John
    [J]. 2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 2819 - 2821
  • [8] Single-seeded coronary artery tracking in CT angiography
    Lavi, G
    Lessick, J
    Johnson, PC
    Khullar, D
    [J]. 2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3308 - 3311
  • [9] Motion estimation and compensation for coronary artery and myocardium in cardiac CT
    Tang, Qiulin
    Matthews, James
    Razeto, Marco
    Linde, Jesper James
    Nakanishi, Satoru
    [J]. MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
  • [10] Velocity of coronary artery motion during the cardiac cycle: measurement by biplane coronary angiography
    Achenbach, S
    Pohle, K
    Ropers, D
    von Korn, H
    Ludwig, J
    Moshage, W
    Daniel, WG
    [J]. EUROPEAN HEART JOURNAL, 2002, 23 : 66 - 66