Quantification of 3-D coronary arterial motion using clinical biplane cineangiograms

被引:45
|
作者
Ding, ZH [1 ]
Friedman, MH [1 ]
机构
[1] Ohio State Univ, Ctr Biomed Engn, Columbus, OH 43210 USA
来源
关键词
arterial motion; coronary arteries; image analysis;
D O I
10.1023/A:1026590417177
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Speculation that the motion of the coronary arteries might be involved in the pathogenesis of coronary atherosclerosis has generated growing interest in the study of this motion. Accordingly, a system has been developed to quantify 3-D coronary arterial motion using clinical biplane cineangiograms. Exploiting the temporal continuity of sequential angiographic images, a template matching technique is designed to track the non-uniform frame-to-frame motion of coronary arteries without assuming that the vessels experience uniform axial strain. The implementation of the system is automated by a coarse-to-fine matching process, thus improving the efficiency and objectivity of motion analysis. The system has been validated and employed to characterize the in vivo motion dynamics of human coronary arteries; illustrative results show that this system is a promising tool for routine clinical and laboratory analysis of coronary arterial motion.
引用
收藏
页码:331 / 346
页数:16
相关论文
共 50 条
  • [1] Quantification of 3-D coronary arterial motion using clinical biplane cineangiograms
    Zhaohua Ding
    Morton H. Friedman
    [J]. The International Journal of Cardiac Imaging, 2000, 16 : 331 - 346
  • [2] Tracking 3-D coronary artery motion with biplane angiography
    Zhu, H
    Friedman, MH
    [J]. 2002 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING, PROCEEDINGS, 2002, : 605 - 608
  • [3] Three-dimensional motion tracking of coronary arteries in biplane cineangiograms
    Shechter, G
    Devernay, F
    Coste-Manière, E
    Quyyumi, A
    McVeigh, ER
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2003, 22 (04) : 493 - 503
  • [4] 3D CORONARY ANGIOGRAPHY - RECONSTRUCTION OF CORONARY CROSS-SECTIONS FROM BIPLANE DIGITAL CINEANGIOGRAMS
    KENET, RO
    HERROLD, EM
    HILL, JP
    FENSTER, P
    BARBA, J
    SUARDIAZ, M
    BORER, JS
    [J]. CLINICAL RESEARCH, 1987, 35 (03): : A291 - A291
  • [5] Quantification of coronary arterial plaque volume using 3D reconstructions formed by fusing intravascular ultrasound and biplane angiography
    Klingensmith, JD
    Vince, DG
    Shekhar, R
    Kuban, B
    Tuzcu, EM
    Cornhill, JF
    [J]. MEDICAL IMAGING 1999: PHYSIOLOGY AND FUNCTION FROM MULTIDIMENSIONAL IMAGES, 1999, 3660 : 343 - 350
  • [6] Accurate 3-D reconstruction of tortuous coronary vessels using biplane angiography and intravascular ultrasound
    Prause, GPM
    DeJong, SC
    McKay, CR
    Sonka, M
    [J]. PHYSIOLOGY AND FUNCTION FROM MULTIDIMENSIONAL IMAGES - MEDICAL IMAGING 1997, 1997, 3033 : 225 - 234
  • [7] RECONSTRUCTING THE 3-D MEDIAL AXES OF CORONARY-ARTERIES IN SINGLE-VIEW CINEANGIOGRAMS
    NGUYEN, TV
    SKLANSKY, J
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1994, 13 (01) : 61 - 73
  • [8] 3D reconstruction of coronary artery using biplane angiography
    Law, AKW
    Zhu, H
    Chan, FHY
    [J]. PROCEEDINGS OF THE 25TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: A NEW BEGINNING FOR HUMAN HEALTH, 2003, 25 : 533 - 536
  • [9] 3-D coronary arterial network structure and flows.
    Byrd, GF
    Lacoin, M
    Bassingthwaighte, JB
    [J]. JOURNAL OF INVESTIGATIVE MEDICINE, 2000, 48 (01) : 65A - 65A
  • [10] Dynamic reconstruction of 3D coronary arterial trees based on a sequence of biplane angiograms
    Chen, SYJ
    Carroll, JD
    [J]. IMAGE PROCESSING - MEDICAL IMAGING 1997, PTS 1 AND 2, 1997, 3034 : 358 - 368