Quantification of 3-D coronary arterial motion using clinical biplane cineangiograms

被引:45
|
作者
Ding, ZH [1 ]
Friedman, MH [1 ]
机构
[1] Ohio State Univ, Ctr Biomed Engn, Columbus, OH 43210 USA
来源
关键词
arterial motion; coronary arteries; image analysis;
D O I
10.1023/A:1026590417177
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Speculation that the motion of the coronary arteries might be involved in the pathogenesis of coronary atherosclerosis has generated growing interest in the study of this motion. Accordingly, a system has been developed to quantify 3-D coronary arterial motion using clinical biplane cineangiograms. Exploiting the temporal continuity of sequential angiographic images, a template matching technique is designed to track the non-uniform frame-to-frame motion of coronary arteries without assuming that the vessels experience uniform axial strain. The implementation of the system is automated by a coarse-to-fine matching process, thus improving the efficiency and objectivity of motion analysis. The system has been validated and employed to characterize the in vivo motion dynamics of human coronary arteries; illustrative results show that this system is a promising tool for routine clinical and laboratory analysis of coronary arterial motion.
引用
收藏
页码:331 / 346
页数:16
相关论文
共 50 条
  • [21] 3-D catheter path reconstruction from biplane angiograms
    Molina, C
    Prause, G
    Radeva, P
    Sonka, M
    [J]. MEDICAL IMAGING 1998: IMAGE PROCESSING, PTS 1 AND 2, 1998, 3338 : 504 - 512
  • [22] Motion analysis using the 3-D Gabor transform
    Reed, TR
    [J]. THIRTIETH ASILOMAR CONFERENCE ON SIGNALS, SYSTEMS & COMPUTERS, VOLS 1 AND 2, 1997, : 506 - 509
  • [23] Characterization of 3-D Coronary Tree Motion From MSCT Angiography
    Yang, Guanyu
    Zhou, Jian
    Boulmier, Dominique
    Garcia, Marie-Paule
    Luo, Limin
    Toumoulin, Christine
    [J]. IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2010, 14 (01): : 101 - 106
  • [24] 3-D OBJECT RECONSTRUCTION USING STEREO AND MOTION
    GROSSO, E
    SANDINI, G
    TISTARELLI, M
    [J]. IEEE TRANSACTIONS ON SYSTEMS MAN AND CYBERNETICS, 1989, 19 (06): : 1465 - 1476
  • [25] 3-D motion estimation using range data
    Gharavi, Hamid
    Gao, Shaoshuai
    [J]. IEEE TRANSACTIONS ON INTELLIGENT TRANSPORTATION SYSTEMS, 2007, 8 (01) : 133 - 143
  • [26] Geometrically correct 3-D reconstruction of tortuous coronary arteries: Fusion of biplane coronary angiography and intravascular ultrasound pullback imaging
    Prause, G
    DeJong, SC
    McKay, CR
    Sonka, M
    [J]. CIRCULATION, 1996, 94 (08) : 1492 - 1492
  • [27] Towards a geometrically correct 3-D reconstruction of tortuous coronary arteries based on biplane angiography and intravascular ultrasound
    Guido P.M. Prause
    Steven C. DeJong
    Charles R. McKay
    Milan Sonka
    [J]. The International Journal of Cardiac Imaging, 1997, 13 : 451 - 462
  • [28] Towards a geometrically correct 3-D reconstruction of tortuous coronary arteries based on biplane angiography and intravascular ultrasound
    Prause, GPM
    DeJong, SC
    McKay, CR
    Sonka, M
    [J]. INTERNATIONAL JOURNAL OF CARDIAC IMAGING, 1997, 13 (06): : 451 - 462
  • [29] A comprehensive method for geometrically correct 3-D reconstruction of coronary arteries by fusion of intravascular ultrasound and biplane angiography
    Wahle, A
    Prause, GPM
    DeJong, SC
    Sonka, M
    [J]. COMPUTER-AIDED DIAGNOSIS IN MEDICAL IMAGING, 1999, 1182 : 363 - 368
  • [30] Quantification of thyroid volume using 3-D ultrasound imaging
    Kollorz, Eva N. K.
    Hahn, Dieter A.
    Linke, Rainer
    Goecke, Tamme W.
    Hornegger, Joachim
    Kuwert, Torsten
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2008, 27 (04) : 457 - 466