Activation of blood coagulation at heparin-coated surfaces

被引:0
|
作者
Blezer, R
Fouache, B
Willems, GM
Lindhout, T
机构
[1] UNIV LIMBURG,DEPT BIOCHEM,NL-6200 MD MAASTRICHT,NETHERLANDS
[2] UNIV LIMBURG,CARDIOVASC RES INST MAASTRICHT,NL-6200 MD MAASTRICHT,NETHERLANDS
[3] MEDTRON BAKKEN RES CTR,DEPT BIOMAT TECHNOL,MAASTRICHT,NETHERLANDS
来源
关键词
immobilized heparin; contact activation; thrombin generation;
D O I
10.1002/(SICI)1097-4636(199710)37:1<108::AID-JBM13>3.0.CO;2-C
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
It is hypothesized that immobilized heparin exerts a dual role in blood coagulation. On the one hand, the heparinized surface is because of its dense negative charge, thought to initiate the intrinsic pathway of blood coagulation. On the other hand, heparin is known as a potent anticoagulant drug. However, it remains to be seen how much contact-phase activation of factor XI contributes to thrombin formation and how this process is counterbalanced by which of the anti-protease activities of immobilized heparin. In the present study we examined the generation of factors XIa, IXa, and Xa, and thrombin in recalcified normal and antithrombin-depleted plasma exposed to polyacrylamide-graft polyurethane (PU) sheets modified by multipoint attachment of two different heparin species. One of them, HAH, contained the specific antithrombin binding sequence and the other one, NAH, had a low affinity for antithrombin and had no anticoagulant activity. Our data demonstrate that in contrast to PU, PU-NAH and PU-HAH are strong mediators of factor XIa and factor IXa formation in normal and antithrombin-deficient plasma. Interestingly, compared to PU-HAH and PU-NAH, thrombin formation was only slightly diminished in antithrombin-deficient plasma exposed to PU. In contrast, thrombin formation was dramatically delayed and diminished in normal plasma exposed to PU-HAH. These findings indicate that very low amounts of factor XIa apparently suffice to induce significant amounts of thrombin. Ln this sense, heparinized surfaces are highly thrombogenic, but our delta also indicate that this activity is effectively counterbalanced by the anti-thrombin activity of the immobilized anti-coagulant species of heparin. (C) 1997 John Wiley & Sons, Inc.
引用
收藏
页码:108 / 113
页数:6
相关论文
共 50 条
  • [41] Attenuation of changes in leukocyte surface markers and complement activation with heparin-coated cardiopulmonary bypass
    Moen, O
    Hogasen, K
    Fosse, E
    Dregelid, E
    Brockmeier, V
    Venge, P
    Harboe, M
    Mollnes, TE
    ANNALS OF THORACIC SURGERY, 1997, 63 (01): : 105 - 111
  • [42] Reducing inflammatory reactions by heparin-coated circuit
    Wan, S
    Izzat, MB
    Yim, APC
    ANNALS OF THORACIC SURGERY, 1998, 66 (05): : 1868 - 1868
  • [43] Issues of biocompatibility: Heparin-coated extracorporeal circuit
    Hsu, LC
    INTERNATIONAL ANESTHESIOLOGY CLINICS, 1996, 34 (02) : 109 - 122
  • [44] THROMBOGENICITY OF HEPARIN-COATED AND NON-HEPARIN-COATED CATHETERS - CLINICAL-TRIAL
    KIDO, DK
    PAULIN, S
    ALENGHAT, JA
    WATERNAUX, C
    RILEY, WD
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1982, 3 (05) : 535 - 539
  • [45] HEPARIN-BEARING SURFACES AND LIQUID SURFACES IN RELATION TO BLOOD COAGULATION
    FOURT, L
    SCHWARTZ, AM
    QUASIUS, A
    BOWMAN, RL
    TRANSACTIONS AMERICAN SOCIETY FOR ARTIFICIAL INTERNAL ORGANS, 1966, 12 (APR): : 155 - &
  • [46] REDUCED COMPLEMENT ACTIVATION WITH HEPARIN-COATED OXYGENATOR AND TUBINGS IN CORONARY-BYPASS OPERATIONS
    VIDEM, V
    SVENNEVIG, JL
    FOSSE, E
    SEMB, G
    OSTERUD, A
    MOLLNES, TE
    NIELSEN, H
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1992, 103 (04): : 806 - 813
  • [47] THROMBOGENICITY OF HEPARIN-COATED AND NON-HEPARIN-COATED CATHETERS - CLINICAL-TRIAL
    KIDO, DK
    PAULIN, S
    ALENGHAT, JA
    WATERNAUX, C
    RILEY, WD
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1982, 139 (05) : 957 - 961
  • [48] Global and extended coagulation monitoring during extracorporeal lung assist with heparin-coated systems in ARDS patients
    Gerlach, M
    Fohre, B
    Keh, D
    Riess, H
    Falke, KJ
    Gerlach, H
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1997, 20 (01): : 29 - 36
  • [49] Evaluation of coagulation and anti-Xa factor using a heparin-coated AN69ST® dialyser
    Sanchez-Canel, Juan J.
    Pons-Prades, Ramon
    Laura Salvetti, M.
    Milagros Vazquez, Alejandro Seores
    Perez-Alba, Alejandro
    Tamarit, Esther
    Calvo-Gordo, Consuelo
    Villatoro, Juan
    NEFROLOGIA, 2012, 32 (05): : 605 - 612
  • [50] A comparative evaluation of the effect of pump type and heparin-coated surfaces on platelets during cardiopulmonary bypass
    Misoph, M
    Babin-Ebell, J
    Schwender, S
    THORACIC AND CARDIOVASCULAR SURGEON, 1997, 45 (06): : 302 - 306