Activation of blood coagulation at heparin-coated surfaces

被引:0
|
作者
Blezer, R
Fouache, B
Willems, GM
Lindhout, T
机构
[1] UNIV LIMBURG,DEPT BIOCHEM,NL-6200 MD MAASTRICHT,NETHERLANDS
[2] UNIV LIMBURG,CARDIOVASC RES INST MAASTRICHT,NL-6200 MD MAASTRICHT,NETHERLANDS
[3] MEDTRON BAKKEN RES CTR,DEPT BIOMAT TECHNOL,MAASTRICHT,NETHERLANDS
来源
关键词
immobilized heparin; contact activation; thrombin generation;
D O I
10.1002/(SICI)1097-4636(199710)37:1<108::AID-JBM13>3.0.CO;2-C
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
It is hypothesized that immobilized heparin exerts a dual role in blood coagulation. On the one hand, the heparinized surface is because of its dense negative charge, thought to initiate the intrinsic pathway of blood coagulation. On the other hand, heparin is known as a potent anticoagulant drug. However, it remains to be seen how much contact-phase activation of factor XI contributes to thrombin formation and how this process is counterbalanced by which of the anti-protease activities of immobilized heparin. In the present study we examined the generation of factors XIa, IXa, and Xa, and thrombin in recalcified normal and antithrombin-depleted plasma exposed to polyacrylamide-graft polyurethane (PU) sheets modified by multipoint attachment of two different heparin species. One of them, HAH, contained the specific antithrombin binding sequence and the other one, NAH, had a low affinity for antithrombin and had no anticoagulant activity. Our data demonstrate that in contrast to PU, PU-NAH and PU-HAH are strong mediators of factor XIa and factor IXa formation in normal and antithrombin-deficient plasma. Interestingly, compared to PU-HAH and PU-NAH, thrombin formation was only slightly diminished in antithrombin-deficient plasma exposed to PU. In contrast, thrombin formation was dramatically delayed and diminished in normal plasma exposed to PU-HAH. These findings indicate that very low amounts of factor XIa apparently suffice to induce significant amounts of thrombin. Ln this sense, heparinized surfaces are highly thrombogenic, but our delta also indicate that this activity is effectively counterbalanced by the anti-thrombin activity of the immobilized anti-coagulant species of heparin. (C) 1997 John Wiley & Sons, Inc.
引用
收藏
页码:108 / 113
页数:6
相关论文
共 50 条
  • [21] Platelet activation after stenting with heparin-coated versus noncoated stents
    Gurbel, PA
    Bliden, KP
    Hiatt, BL
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (06) : 13A - 13A
  • [22] Platelet activation after stenting with heparin-coated versus noncoated stents
    Gurbel, PA
    Bliden, KP
    AMERICAN HEART JOURNAL, 2003, 146 (04)
  • [23] HEPARIN-COATED CATHETERS AND HEPARIN-INDUCED THROMBOCYTOPENIA
    LASTER, J
    SILVER, D
    JOURNAL OF VASCULAR SURGERY, 1988, 7 (05) : 667 - 672
  • [24] Heparin-coated Bypasses for femoropopliteal Reconstructions
    不详
    GEFASSCHIRURGIE, 2016, 21 (07): : 460 - 461
  • [25] Complete heparin-coated cardiopulmonary bypass and low heparin dose reduce complement and granulocyte activation
    Ovrum, E
    Fosse, E
    Mollnes, TE
    Holen, EA
    Tangen, G
    Abdelnoor, M
    Ringdal, MAL
    Oystese, R
    Venge, P
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1996, 10 (01) : 54 - 60
  • [26] USE OF HEPARIN-COATED CARDIOPULMONARY BYPASS
    JONES, DR
    HILL, RC
    HOLLINGSED, MJ
    STULLKEN, E
    GRAEBER, GM
    GUSTAFSON, RA
    MURRAY, GF
    ANNALS OF THORACIC SURGERY, 1993, 56 (03): : 556 - 558
  • [27] Biomaterial-dependent blood activation during simulated extracorporeal circulation: a study of heparin-coated and uncoated circuits
    Borowiec, JW
    Venge, P
    Henze, A
    Nilsson, B
    Stiernstrom, H
    THORACIC AND CARDIOVASCULAR SURGEON, 1997, 45 (06): : 295 - 301
  • [28] Biocompatibility in heparin-coated extracorporeal circuits
    Hsu, Li-Chien
    PERFUSION-UK, 1996, 11 (03): : 256 - 263
  • [29] Cytokine release and neutrophil activation are not prevented by heparin-coated circuits and aprotinin administration
    Defraigne, JO
    Pincemail, J
    Larbuisson, R
    Blaffart, F
    Limet, R
    ANNALS OF THORACIC SURGERY, 2000, 69 (04): : 1084 - 1091
  • [30] Heparin-coated circuits reduce complement activation and inflammatory response to cardiopulmonary bypass
    Tamim, M
    Demircin, E
    Guvener, M
    Peker, O
    Yilmaz, M
    PANMINERVA MEDICA, 1999, 41 (03) : 193 - 198