Activation of blood coagulation at heparin-coated surfaces

被引:0
|
作者
Blezer, R
Fouache, B
Willems, GM
Lindhout, T
机构
[1] UNIV LIMBURG,DEPT BIOCHEM,NL-6200 MD MAASTRICHT,NETHERLANDS
[2] UNIV LIMBURG,CARDIOVASC RES INST MAASTRICHT,NL-6200 MD MAASTRICHT,NETHERLANDS
[3] MEDTRON BAKKEN RES CTR,DEPT BIOMAT TECHNOL,MAASTRICHT,NETHERLANDS
来源
关键词
immobilized heparin; contact activation; thrombin generation;
D O I
10.1002/(SICI)1097-4636(199710)37:1<108::AID-JBM13>3.0.CO;2-C
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
It is hypothesized that immobilized heparin exerts a dual role in blood coagulation. On the one hand, the heparinized surface is because of its dense negative charge, thought to initiate the intrinsic pathway of blood coagulation. On the other hand, heparin is known as a potent anticoagulant drug. However, it remains to be seen how much contact-phase activation of factor XI contributes to thrombin formation and how this process is counterbalanced by which of the anti-protease activities of immobilized heparin. In the present study we examined the generation of factors XIa, IXa, and Xa, and thrombin in recalcified normal and antithrombin-depleted plasma exposed to polyacrylamide-graft polyurethane (PU) sheets modified by multipoint attachment of two different heparin species. One of them, HAH, contained the specific antithrombin binding sequence and the other one, NAH, had a low affinity for antithrombin and had no anticoagulant activity. Our data demonstrate that in contrast to PU, PU-NAH and PU-HAH are strong mediators of factor XIa and factor IXa formation in normal and antithrombin-deficient plasma. Interestingly, compared to PU-HAH and PU-NAH, thrombin formation was only slightly diminished in antithrombin-deficient plasma exposed to PU. In contrast, thrombin formation was dramatically delayed and diminished in normal plasma exposed to PU-HAH. These findings indicate that very low amounts of factor XIa apparently suffice to induce significant amounts of thrombin. Ln this sense, heparinized surfaces are highly thrombogenic, but our delta also indicate that this activity is effectively counterbalanced by the anti-thrombin activity of the immobilized anti-coagulant species of heparin. (C) 1997 John Wiley & Sons, Inc.
引用
收藏
页码:108 / 113
页数:6
相关论文
共 50 条
  • [1] PLATELET AND COAGULATION ACTIVATION BY HEPARIN-COATED CARDIOPULMONARY BYPASS SYSTEMS
    KOTTKEMARCHANT, K
    BORSCH, J
    MCCARTHY, P
    LAASCH, C
    BROOKS, L
    MUEHRCKE, D
    THROMBOSIS AND HAEMOSTASIS, 1995, 73 (06) : 1344 - 1344
  • [2] ACTIVATION OF ANTI-THROMBIN BY HEPARIN-COATED THROMBORESISTANT SURFACES
    SILANE, M
    LINDON, J
    LABARRE, D
    BRIERRUSSELL, D
    ROSENBERG, R
    MERRILL, E
    SALZMAN, E
    CLINICAL RESEARCH, 1980, 28 (02): : A497 - A497
  • [3] Interactions of protamine with heparin-coated artificial surfaces
    Wendel, HP
    Jurmann, M
    Scheule, A
    Heller, W
    Ziemer, G
    THROMBOSIS AND HAEMOSTASIS, 1997, : PS425 - PS425
  • [4] Eosinophil granulocyte activation and heparin-coated cardiopulmonary
    Ovrum, E
    ANNALS OF THORACIC SURGERY, 1996, 61 (03): : 1038 - 1039
  • [5] DISPARITY IN BLOOD ACTIVATION BY 2 DIFFERENT HEPARIN-COATED CARDIOPULMONARY BYPASS SYSTEMS
    MOEN, O
    FOSSE, E
    BROCKMEIER, V
    ANDERSSON, C
    MOLLNES, TE
    HOGASEN, K
    VENGE, P
    ANNALS OF THORACIC SURGERY, 1995, 60 (05): : 1317 - 1323
  • [6] Haemocompatibility of paediatric membrane oxygenators with heparin-coated surfaces
    Wendel, HP
    Scheule, AM
    Eckstein, FS
    Ziemer, G
    PERFUSION-UK, 1999, 14 (01): : 21 - 28
  • [7] The stability of heparin-coated liposomes in plasma and their effect on its coagulation
    Sahli, A
    Cansell, M
    Tapon-Bretaudiere, J
    Letourneur, D
    Jozefonvicz, J
    Fischer, AM
    COLLOIDS AND SURFACES B-BIOINTERFACES, 1998, 10 (04) : 205 - 215
  • [8] Differences in blood activation related to roller/centrifugal pumps and heparin-coated/uncoated surfaces in a cardiopulmonary bypass model circuit
    Moen, O.
    Fosse, E.
    Braten, J.
    Andersson, C.
    Hogasen, K.
    Mollnes, T. E.
    Venge, P.
    Kierulf, P.
    PERFUSION-UK, 1996, 11 (02): : 113 - 123
  • [9] Heparin-coated stents
    Kocsis, JF
    Llanos, G
    Holmer, E
    JOURNAL OF LONG-TERM EFFECTS OF MEDICAL IMPLANTS, 2000, 10 (1-2) : 19 - 45
  • [10] Coagulation, fibrinolysis, and cell activation in patients and in shed mediastinal blood during coronary artery bypass grafting with a new heparin-coated surface
    Baufreton, C
    de Brux, JL
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2003, 126 (06): : 2116 - 2116