Efficacy of incorporating PCM into the building envelope on the energy saving and AHU power usage in winter

被引:52
|
作者
Abu-Hamdeh, Nidal H. [1 ,2 ]
Melaibari, Ammar A. [2 ]
Alquthami, Thamer S. [3 ]
Khoshaim, Ahmed [2 ]
Oztop, Hakan F. [2 ,4 ]
Karimipour, Aliakbar [5 ]
机构
[1] King Abdulaziz Univ, Fac Engn, Ctr Res Excellence Renewable Energy & Power Syst, Jeddah 21589, Saudi Arabia
[2] King Abdulaziz Univ, Fac Engn, Dept Mech Engn, Jeddah 21589, Saudi Arabia
[3] King Abdulaziz Univ, Fac Engn, Dept Elect & Comp Engn, Jeddah 21511, Saudi Arabia
[4] Firat Univ, Technol Fac, Dept Mech Engn, Elazig, Turkey
[5] Duy Tan Univ, Inst Res & Dev, Da Nang 550000, Vietnam
关键词
Phase change material; Envelope; Air handling unit; Energy saving; Economic analysis;
D O I
10.1016/j.seta.2020.100969
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Commercial and residential buildings consume 20% of the world's total energy usage and forecasts indicate a growing trend of 1.5% per year by 2040. Share of energy consumption in the heating ventilation and air conditioning (HVAC) reached to 40-70% of the building energy usage. Reduction in the heat exchange between the interior and exterior spaces is an energy-efficient technique for lowering HVAC energy demand. In this study, the thermal performance of a PCM-based wall was numerically examined in the winter. The main purpose of this research was to investigate the efficacy of installing PCM inside the envelope on reducing heat loss from the conditioned space and at the same time its effect on air handling unit (AHU) energy usage. For this, seven different PCM layers at melting temperatures of 276.15-293.15 K with a thickness of 1 cm were loaded into the envelope. Based on the results, among the PCMs thermophysical properties, thermal conductivity has more manifest efficacy. Under the best conditions, owing to installing PCM of A3 inside the envelope, the energy-saving in December, January and February diminished by 11.25%, 11.23% and 10.35%, respectively. Also, thermodynamic calculations affirmed that the maximum reduction in AHU power usage owing to PCM loading was 11.73%. Using payback time technique, the economic analysis was performed and it was found that under the best conditions, the payback time is 18.6 years.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] An experimental evaluation of thermal behavior of the building envelope using macroencapsulated PCM for energy savings
    Rathore, Pushpendra Kumar Singh
    Shukla, Shailendra Kumar
    [J]. RENEWABLE ENERGY, 2020, 149 (149) : 1300 - 1313
  • [32] Energy usage and technical potential for energy saving measures in the Swedish residential building stock
    Mata, Erika
    Kalagasidis, Angela Sasic
    Johnsson, Filip
    [J]. ENERGY POLICY, 2013, 55 : 404 - 414
  • [33] Influential aspects on melting and solidification of PCM energy storage containers in building envelope applications
    Al-Yasiri, Qudama
    Szabo, Marta
    [J]. INTERNATIONAL JOURNAL OF GREEN ENERGY, 2021, 18 (09) : 966 - 986
  • [34] Building Power Management for Energy Saving: A Case Study of University Building
    Mangkalajan, Satit
    Julsereewong, Prasit
    Julsereeong, Amphawan
    [J]. 2012 12TH INTERNATIONAL CONFERENCE ON CONTROL, AUTOMATION AND SYSTEMS (ICCAS), 2012, : 1778 - 1782
  • [35] Potential evaluation of energy flexibility and energy-saving of PCM-integrated office building walls
    Dong, Yuanyuan
    Zhang, Ling
    Wang, Pengcheng
    Liu, Zhongbing
    Su, Xiaosong
    Liao, Hongjing
    Jiang, Xiangyang
    [J]. JOURNAL OF BUILDING ENGINEERING, 2023, 79
  • [36] The Urban Villages Building Envelope Energy-Saving Research in Northwestern Henan
    Zhang, Xianmei
    Yan, Shuaiping
    [J]. SUSTAINABLE ENVIRONMENT AND TRANSPORTATION, PTS 1-4, 2012, 178-181 : 173 - 178
  • [37] Impact of Building Envelope Materials on Energy Usage and Performance of Evaporative Cooling System in Residential Building
    Thongsuk, Surakit
    Songsukthawan, Panapong
    Lertwanitrot, Praikanok
    Ananwattanaporn, Santipont
    Yoomak, Suntiti
    Pothisarn, Chaichan
    [J]. ENERGIES, 2024, 17 (15)
  • [38] Energy saving analyses on envelope thermal properties in hot summer and cold winter region
    Wang H.
    Zhuang Y.
    Wu W.
    [J]. Tongji Daxue Xuebao/Journal of Tongji University, 2010, 38 (11): : 1641 - 1646+1700
  • [39] Energy-saving Application of "gas - solid - hot" of Coupling in Building Envelope
    Gong Jing
    Liu Lisheng
    [J]. 2010 INTERNATIONAL SYMPOSIUM ON MULTI-FIELD COUPLING THEORY OF ROCK AND SOIL MEDIA AND ITS APPLICATIONS, 2010, : 721 - 724
  • [40] Energy-Saving Potential of Building Envelope Designs in Residential Houses in Taiwan
    Lai, Chi-Ming
    Wang, Yao-Hong
    [J]. ENERGIES, 2011, 4 (11) : 2061 - 2076