Efficacy of incorporating PCM into the building envelope on the energy saving and AHU power usage in winter

被引:52
|
作者
Abu-Hamdeh, Nidal H. [1 ,2 ]
Melaibari, Ammar A. [2 ]
Alquthami, Thamer S. [3 ]
Khoshaim, Ahmed [2 ]
Oztop, Hakan F. [2 ,4 ]
Karimipour, Aliakbar [5 ]
机构
[1] King Abdulaziz Univ, Fac Engn, Ctr Res Excellence Renewable Energy & Power Syst, Jeddah 21589, Saudi Arabia
[2] King Abdulaziz Univ, Fac Engn, Dept Mech Engn, Jeddah 21589, Saudi Arabia
[3] King Abdulaziz Univ, Fac Engn, Dept Elect & Comp Engn, Jeddah 21511, Saudi Arabia
[4] Firat Univ, Technol Fac, Dept Mech Engn, Elazig, Turkey
[5] Duy Tan Univ, Inst Res & Dev, Da Nang 550000, Vietnam
关键词
Phase change material; Envelope; Air handling unit; Energy saving; Economic analysis;
D O I
10.1016/j.seta.2020.100969
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Commercial and residential buildings consume 20% of the world's total energy usage and forecasts indicate a growing trend of 1.5% per year by 2040. Share of energy consumption in the heating ventilation and air conditioning (HVAC) reached to 40-70% of the building energy usage. Reduction in the heat exchange between the interior and exterior spaces is an energy-efficient technique for lowering HVAC energy demand. In this study, the thermal performance of a PCM-based wall was numerically examined in the winter. The main purpose of this research was to investigate the efficacy of installing PCM inside the envelope on reducing heat loss from the conditioned space and at the same time its effect on air handling unit (AHU) energy usage. For this, seven different PCM layers at melting temperatures of 276.15-293.15 K with a thickness of 1 cm were loaded into the envelope. Based on the results, among the PCMs thermophysical properties, thermal conductivity has more manifest efficacy. Under the best conditions, owing to installing PCM of A3 inside the envelope, the energy-saving in December, January and February diminished by 11.25%, 11.23% and 10.35%, respectively. Also, thermodynamic calculations affirmed that the maximum reduction in AHU power usage owing to PCM loading was 11.73%. Using payback time technique, the economic analysis was performed and it was found that under the best conditions, the payback time is 18.6 years.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Incorporating power converters for energy saving marine applications
    Papanikolaou, N.
    Kyritsis, A.
    Loupis, M.
    [J]. 2014 INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES (ICEM), 2014, : 2306 - 2311
  • [22] Experimental study on thermal comfort improvement of building envelope with PCM energy storage
    Ye, H.
    Wang, Y.
    Qian, F.
    [J]. SUSTAINABLE BUILDINGS AND STRUCTURES: BUILDING A SUSTAINABLE TOMORROW, 2020, : 213 - 220
  • [23] Effects of envelope energy saving strategies on different rooms in residential building
    Yu, Jinghua
    Yang, Changzhi
    Tian, Liwei
    Hu, Junwen
    [J]. PROCEEDINGS OF THE 5TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I AND II, 2007, : 871 - 878
  • [24] Evaluating energy consumption saving from translucent concrete building envelope
    Ahuja, Aashish
    Mosalam, Khalid M.
    [J]. ENERGY AND BUILDINGS, 2017, 153 : 448 - 460
  • [25] Energy-Saving Design of Building Envelope Based on Multiparameter Optimization
    Gan, Weinan
    Cao, Yunzhong
    Jiang, Wen
    Li, Liangqiang
    Li, Xiaolin
    [J]. MATHEMATICAL PROBLEMS IN ENGINEERING, 2019, 2019
  • [26] New building envelope structures. Energy saving and moisture technology
    Kokko, Erkki
    Ojanen, Tuomo
    Salonvaara, Mikael
    [J]. VTT Tiedotteita - Valtion Teknillinen Tutkimuskeskus, (1869):
  • [27] THE INFLUENCE OF RURAL BUILDING ENERGY SAVING DESIGN ON CLEAN ENERGY HEATING IN WINTER
    Shun, Rao
    [J]. THERMAL SCIENCE, 2021, 25 (04): : 3103 - 3112
  • [28] Implementation of ANN and GA on building with PCM at various setpoints, PCM types, and installation locations to boost energy saving and CO2 saving
    Abbasian-Naghneh, Salman
    Kalbasi, Rasool
    [J]. ENGINEERING ANALYSIS WITH BOUNDARY ELEMENTS, 2022, 144 : 110 - 126
  • [29] Improvement in Energy Performance of Building Envelope Incorporating Electrochromic Windows (ECWs)
    Park, Bo Rang
    Hong, Jongin
    Choi, Eun Ji
    Choi, Young Jae
    Lee, Choonyeob
    Moon, Jin Woo
    [J]. ENERGIES, 2019, 12 (06)
  • [30] Application of Energy Consumption Simulation in Envelope Energy-Saving Reconstruction of Existing Building
    Cui, Yanqiu
    Wei, Ruihan
    Luo, Cailing
    Miao, Jikui
    [J]. ARCHITECTURE AND BUILDING MATERIALS, PTS 1 AND 2, 2011, 99-100 : 644 - +