Deciphering Complement Interference in Anti-Human Leukocyte Antigen Antibody Detection With Flow Beads Assays

被引:85
|
作者
Visentin, Jonathan [1 ,2 ]
Vigata, Margaux [1 ]
Daburon, Sophie [2 ]
Contin-Bordes, Cecile [1 ,2 ]
Fremeaux-Bacchi, Veronique [3 ]
Dromer, Claire [4 ]
Billes, Marc-Alain [5 ]
Neau-Cransac, Martine [6 ]
Guidicelli, Gwendaline [1 ]
Taupin, Jean-Luc [1 ,2 ]
机构
[1] CHU Bordeaux, Hop Pellegrin, Lab Immunol & Immunogenet, F-33076 Bordeaux, France
[2] Univ Bordeaux, CNRS, UMR 5164, Talence, France
[3] Hop Europeen Georges Pompidou, Assistance Publ Hop Paris, Lab Immunol Biol, Paris, France
[4] CHU Bordeaux, Hop Haut Leveque, Serv Malad Resp, Pessac, France
[5] CHU Bordeaux, Hop Haut Leveque, Serv Chirurg Cardiaque, Pessac, France
[6] CHU Bordeaux, Hop Pellegrin, Serv Transplantat Hepat, F-33076 Bordeaux, France
关键词
HLA antibodies; Single antigen flow beads; Prozone phenomenon; Interference; Complement; HLA; ACTIVATION; IGG;
D O I
10.1097/TP.0000000000000315
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Background. Anti-human leukocyte antigen (HLA) antibody detection in solid-phase flow beads assays can be quenched by complement activation, but the precise mechanism of this interference is not fully elucidated yet. Methods. Using the Luminex flow beads screening assay for detection of anti-HLA antibodies, we analyzed the binding of high concentrations of the pan class I anti-HLA monoclonal antibody W6/32 in neat normal, ethylenediaminetetraacetic acid-treated normal and complement factors C1q, C4/C3, C2, C3, factor B or C5-depleted human sera, using anti-mouse immunoglobulin G as the detection antibody. Complement activation and binding to beads were revealed using anti-human C1q, C4d, and C3d antibodies. To translate our findings to the human setting, we used the class I and class II HLA single-antigen flow beads assays and sera from four patients with high titers of antibodies. Results. Detection of W6/32 did not suffer any interference with C1q and C4/C3-depleted sera. A partial quenching was observed with C2, C3, and factor B-depleted sera, but was more pronounced with the factor B-depleted serum. W6/32 was undetectable in presence of C5-depleted serum. The binding of activation products derived from C3 principally, and also from C4, impaired immunoglobulin G and C1q detection. Accordingly, C4d detection was hindered by deposition of activated C3. Similar findings were obtained with patients' sera. Conclusion. Binding of C4 and C3 activation products is the main responsible for complement interference in flow beads assays. A complete quenching requires complement activation through C3 cleavage and its amplification by the alternative pathway.
引用
收藏
页码:625 / 631
页数:7
相关论文
共 50 条
  • [41] Anti-Human Leukocyte Antigen Antibodies and Development of Graft Failure After Renal Transplantation
    van Timmeren, Mirjan M.
    Lems, Simon P. M.
    Hepkema, Bouke G.
    Bakker, Stephan J. L.
    TRANSPLANTATION, 2009, 88 (12) : 1399 - 1400
  • [42] Assessment of Anti-Human Leukocyte Antigen (HLA)-Antibody-Dependent Humoral Response in Patients before and after Lung Transplantation
    Stanjek-Cichoracka, Anita
    Ochman, Marek
    Chelmecka, Elzbieta
    Hrapkowicz, Tomasz
    MEDICINA-LITHUANIA, 2022, 58 (12):
  • [43] Ventricular assist device-associated anti-human leukocyte antigen antibody sensitization in pediatric patients bridged to heart transplantation
    O'Connor, Matthew J.
    Menteer, JonDavid
    Chrisant, Maryanne R. K.
    Monos, Dimitrios
    Lind, Curt
    Levine, Selena
    Gaynor, J. William
    Hanna, Brian D.
    Paridon, Stephen M.
    Ravishankar, Chitra
    Kaufman, Beth D.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2010, 29 (01): : 109 - 116
  • [44] Use of Single-Antigen Flow Beads Assays to Assess Anti-HLA Donor-Specific Antibody Strength
    Loiseau, Pascale
    Amokhrane, Kahina
    Visentin, Jonathan
    Kheav, Vissal-David
    Caillat-Zucman, Sophie
    Taupin, Jean-Luc
    BIOLOGY OF BLOOD AND MARROW TRANSPLANTATION, 2016, 22 (02) : 394 - 395
  • [45] Leukocyte antigen and antibody detection assays: Tools for assessing and preventing pulmonary transfusion reactions
    Stroncek, David F.
    Fadeyi, Emmanuel
    Adams, Sharon
    TRANSFUSION MEDICINE REVIEWS, 2007, 21 (04) : 273 - 286
  • [46] SIGNIFICANCE OF ANTIGEN-ANTIBODY COMPLEMENT REACTION .3. IDENTIFICATION OF C4 IN IMMUNOELECTROPHORETIC PATTERN OBTAINED WITH ANTI-HUMAN COMPLEMENT SERUM
    PEETOOM, F
    PONDMAN, KW
    VOX SANGUINIS, 1963, 8 (05) : 605 - &
  • [47] POSITIVE REACTION BETWEEN AUSTRALIA-ANTIGEN AND ANTI-HUMAN LIVER ANTIBODY
    PORTOCALA, R
    BABES, VT
    POPESCU, M
    PASCARU, A
    ARCHIV FUR DIE GESAMTE VIRUSFORSCHUNG, 1974, 46 (3-4): : 363 - 365
  • [48] The Impact of Donor-Specific Anti-Human Leukocyte Antigen (HLA) Antibody Rebound on the Risk of Antibody Mediated Rejection in Sensitized Kidney Transplant Recipients
    Lee, Kyo Won
    Park, Jae Berm
    Cho, Chan Woo
    Lee, Nuri
    Yoo, Heejin
    Kim, Kyunga
    Park, Hyojun
    Kang, Eun Suk
    Huh, Wooseong
    Kim, Sungjoo
    ANNALS OF TRANSPLANTATION, 2017, 22 : 166 - 176
  • [49] Removal of therapeutic anti-lymphocyte antibodies from human sera prior to anti-human leukocyte antibody testing
    Bearden, CM
    Book, BK
    Sidner, RA
    Pescovitz, MD
    JOURNAL OF IMMUNOLOGICAL METHODS, 2005, 300 (1-2) : 192 - 199
  • [50] USE OF AN ANTI-HUMAN LEUKOCYTE INTERFERON MONOCLONAL-ANTIBODY FOR THE PURIFICATION AND RADIOIMMUNOASSAY OF HUMAN ALPHA INTERFERON
    MEURS, E
    ROUGEOT, C
    SVAB, J
    LAURENT, AG
    HOVANESSIAN, AG
    ROBERT, N
    GRUEST, J
    MONTAGNIER, L
    DRAY, F
    INFECTION AND IMMUNITY, 1982, 37 (03) : 919 - 926