Deciphering Complement Interference in Anti-Human Leukocyte Antigen Antibody Detection With Flow Beads Assays

被引:85
|
作者
Visentin, Jonathan [1 ,2 ]
Vigata, Margaux [1 ]
Daburon, Sophie [2 ]
Contin-Bordes, Cecile [1 ,2 ]
Fremeaux-Bacchi, Veronique [3 ]
Dromer, Claire [4 ]
Billes, Marc-Alain [5 ]
Neau-Cransac, Martine [6 ]
Guidicelli, Gwendaline [1 ]
Taupin, Jean-Luc [1 ,2 ]
机构
[1] CHU Bordeaux, Hop Pellegrin, Lab Immunol & Immunogenet, F-33076 Bordeaux, France
[2] Univ Bordeaux, CNRS, UMR 5164, Talence, France
[3] Hop Europeen Georges Pompidou, Assistance Publ Hop Paris, Lab Immunol Biol, Paris, France
[4] CHU Bordeaux, Hop Haut Leveque, Serv Malad Resp, Pessac, France
[5] CHU Bordeaux, Hop Haut Leveque, Serv Chirurg Cardiaque, Pessac, France
[6] CHU Bordeaux, Hop Pellegrin, Serv Transplantat Hepat, F-33076 Bordeaux, France
关键词
HLA antibodies; Single antigen flow beads; Prozone phenomenon; Interference; Complement; HLA; ACTIVATION; IGG;
D O I
10.1097/TP.0000000000000315
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Background. Anti-human leukocyte antigen (HLA) antibody detection in solid-phase flow beads assays can be quenched by complement activation, but the precise mechanism of this interference is not fully elucidated yet. Methods. Using the Luminex flow beads screening assay for detection of anti-HLA antibodies, we analyzed the binding of high concentrations of the pan class I anti-HLA monoclonal antibody W6/32 in neat normal, ethylenediaminetetraacetic acid-treated normal and complement factors C1q, C4/C3, C2, C3, factor B or C5-depleted human sera, using anti-mouse immunoglobulin G as the detection antibody. Complement activation and binding to beads were revealed using anti-human C1q, C4d, and C3d antibodies. To translate our findings to the human setting, we used the class I and class II HLA single-antigen flow beads assays and sera from four patients with high titers of antibodies. Results. Detection of W6/32 did not suffer any interference with C1q and C4/C3-depleted sera. A partial quenching was observed with C2, C3, and factor B-depleted sera, but was more pronounced with the factor B-depleted serum. W6/32 was undetectable in presence of C5-depleted serum. The binding of activation products derived from C3 principally, and also from C4, impaired immunoglobulin G and C1q detection. Accordingly, C4d detection was hindered by deposition of activated C3. Similar findings were obtained with patients' sera. Conclusion. Binding of C4 and C3 activation products is the main responsible for complement interference in flow beads assays. A complete quenching requires complement activation through C3 cleavage and its amplification by the alternative pathway.
引用
收藏
页码:625 / 631
页数:7
相关论文
共 50 条
  • [21] Anti-human leukocyte antigen antibodies and preemptive antibody-directed therapy after lung transplantation
    Hachem, Ramsey R.
    Yusen, Roger D.
    Meyers, Bryan F.
    Aloush, Aviva A.
    Mohanakumar, Thalachallour
    Patterson, G. Alexander
    Trulock, Elbert P.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2010, 29 (09): : 973 - 980
  • [22] Strategies for human leukocyte antigen antibody detection
    Bray, Robert A.
    Gebel, Howard M.
    CURRENT OPINION IN ORGAN TRANSPLANTATION, 2009, 14 (04) : 392 - 397
  • [23] Becoming a chef in the human leukocyte antigen kitchen: interpretation and modification of human leukocyte antigen-antibody assays
    Liwski, Robert S.
    Greenshields, Anna L.
    Bray, Robert A.
    Gebel, Howard M.
    CURRENT OPINION IN ORGAN TRANSPLANTATION, 2017, 22 (04) : 407 - 414
  • [24] De Novo Donor-Specific Anti-Human Leukocyte Antigen Antibody Detection in Long-Term Adult Liver Transplantation
    San Segundo, D.
    Alonso, C.
    Ruiz, P.
    Roman, I.
    Arias-Loste, M. T.
    Cuadrado, A.
    Puente, A.
    Casafont, F.
    Lopez-Hoyos, M.
    Crespo, J.
    Fabrega, E.
    TRANSPLANTATION PROCEEDINGS, 2016, 48 (09) : 2980 - 2982
  • [25] Anti-Human Leukocyte Antigen Immunization After Early Allograft Nephrectomy
    Del Bello, Arnaud
    Congy, Nicolas
    Sallusto, Federico
    Cardeau-Desangles, Isabelle
    Fort, Marylise
    Esposito, Laure
    Guitard, Joelle
    Cointault, Olivier
    Lavayssiere, Laurence
    Nogier, Marie Beatrice
    Game, Xavier
    Blancher, Antoine
    Rostaing, Lionel
    Kamar, Nassim
    TRANSPLANTATION, 2012, 93 (09) : 936 - 941
  • [26] Single antigen flow beads for identification of human leukocyte antigen antibody specificities in hypersensitized patients with chronic renal failure
    Soyoz, Mustafa
    Kilicaslan-Ayna, Tulay
    Ozkizilcik-Kocyigit, Asli
    Gulec, Derya
    Pirim, Ibrahim
    CENTRAL EUROPEAN JOURNAL OF IMMUNOLOGY, 2016, 41 (01) : 93 - 100
  • [27] Neonatal alloimmune thrombocytopenia deu to anti-human leukocyte antigen antibodies
    Sasaki, M
    Yagihashi, A
    Kobayashi, D
    Watanabe, N
    Fujikawa, T
    Kudoh, R
    Chiba, S
    Satoh, S
    Morishita, T
    Sekimoto, T
    Katoh, T
    Ikeda, H
    TRANSFUSION, 2000, 40 (10) : 131S - 131S
  • [28] Anti-Human Leukocyte Antigen Immunization after Early Allograft Nephrectomy
    Del Bello, A.
    Congy-Jolivet, N.
    Sallusto, F.
    Cardeau-Desangles, I.
    Esposito, L.
    Blancher, A.
    Rostaing, L.
    Kamar, N.
    AMERICAN JOURNAL OF TRANSPLANTATION, 2012, 12 : 141 - 142
  • [29] Clinical Outcomes of Antibody-Mediated Rejection with or without Anti-human Leukocyte Antigen (HLA) Donor-Specific Antibody
    Ko, Byounghwi
    Jung, Minsun
    Lee, Juhan
    Yang, Jaeseok
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2024, 35 (10):
  • [30] Clinical importance of anti-human leukocyte antigen-specific antibody concentration in performing calculated panel reactive antibody and virtual crossmatches
    Vaidya, Smita
    TRANSPLANTATION, 2008, 85 (07) : 1046 - 1050