Deciphering Complement Interference in Anti-Human Leukocyte Antigen Antibody Detection With Flow Beads Assays

被引:85
|
作者
Visentin, Jonathan [1 ,2 ]
Vigata, Margaux [1 ]
Daburon, Sophie [2 ]
Contin-Bordes, Cecile [1 ,2 ]
Fremeaux-Bacchi, Veronique [3 ]
Dromer, Claire [4 ]
Billes, Marc-Alain [5 ]
Neau-Cransac, Martine [6 ]
Guidicelli, Gwendaline [1 ]
Taupin, Jean-Luc [1 ,2 ]
机构
[1] CHU Bordeaux, Hop Pellegrin, Lab Immunol & Immunogenet, F-33076 Bordeaux, France
[2] Univ Bordeaux, CNRS, UMR 5164, Talence, France
[3] Hop Europeen Georges Pompidou, Assistance Publ Hop Paris, Lab Immunol Biol, Paris, France
[4] CHU Bordeaux, Hop Haut Leveque, Serv Malad Resp, Pessac, France
[5] CHU Bordeaux, Hop Haut Leveque, Serv Chirurg Cardiaque, Pessac, France
[6] CHU Bordeaux, Hop Pellegrin, Serv Transplantat Hepat, F-33076 Bordeaux, France
关键词
HLA antibodies; Single antigen flow beads; Prozone phenomenon; Interference; Complement; HLA; ACTIVATION; IGG;
D O I
10.1097/TP.0000000000000315
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Background. Anti-human leukocyte antigen (HLA) antibody detection in solid-phase flow beads assays can be quenched by complement activation, but the precise mechanism of this interference is not fully elucidated yet. Methods. Using the Luminex flow beads screening assay for detection of anti-HLA antibodies, we analyzed the binding of high concentrations of the pan class I anti-HLA monoclonal antibody W6/32 in neat normal, ethylenediaminetetraacetic acid-treated normal and complement factors C1q, C4/C3, C2, C3, factor B or C5-depleted human sera, using anti-mouse immunoglobulin G as the detection antibody. Complement activation and binding to beads were revealed using anti-human C1q, C4d, and C3d antibodies. To translate our findings to the human setting, we used the class I and class II HLA single-antigen flow beads assays and sera from four patients with high titers of antibodies. Results. Detection of W6/32 did not suffer any interference with C1q and C4/C3-depleted sera. A partial quenching was observed with C2, C3, and factor B-depleted sera, but was more pronounced with the factor B-depleted serum. W6/32 was undetectable in presence of C5-depleted serum. The binding of activation products derived from C3 principally, and also from C4, impaired immunoglobulin G and C1q detection. Accordingly, C4d detection was hindered by deposition of activated C3. Similar findings were obtained with patients' sera. Conclusion. Binding of C4 and C3 activation products is the main responsible for complement interference in flow beads assays. A complete quenching requires complement activation through C3 cleavage and its amplification by the alternative pathway.
引用
收藏
页码:625 / 631
页数:7
相关论文
共 50 条
  • [1] DECIPHERING COMPLEMENT INTERFERENCE WITH ANTI-HLA ANTIBODY DETECTION IN FLOW BEADS ASSAYS
    Visentin, Jonathan
    Vigata, Margaux
    Daburon, Sophie
    Contin-Bordes, Cecile
    Fremeaux-Bacchi, Veronique
    Dromer, Claire
    Billes, Marc-Alain
    Neau-Cransac, Martine
    Guidicelli, Gwendaline
    Taupin, Jean-Luc
    TISSUE ANTIGENS, 2014, 84 (01): : 66 - 66
  • [2] The effect of antithymocyte globulin on anti-human leukocyte antigen antibody detection assays
    Gloor, James M.
    Moore, S. Breanndan
    Schneider, Brittany A.
    DeGoey, Steven R.
    Stegall, Mark D.
    TRANSPLANTATION, 2007, 84 (02) : 258 - 264
  • [3] DECIPHERING IGM INTERFERENCE IN IGG ANTI-HLA ANTIBODY DETECTION WITH FLOW BEADS ASSAYS
    Visentin, Jonathan
    Guidicelli, Gwendaline
    Couzi, Lionel
    Merville, Pierre
    Lee, Jar-How
    Di Primo, Carmelo
    Taupin, Jean-Luc
    HLA, 2016, 87 (04) : 249 - 250
  • [4] Deciphering IgM interference in IgG anti-HLA antibody detection with flow beads assays
    Visentin, Jonathan
    Guidicelli, Gwendaline
    Couzi, Lionel
    Merville, Pierre
    Lee, Jar-How
    Di Primo, Carmelo
    Taupin, Jean-Luc
    HUMAN IMMUNOLOGY, 2016, 77 (11) : 1048 - 1054
  • [5] Effects of Anti-Human Leukocyte Antigen Antibody After Heart Transplantation
    Liou, F.
    Kittleson, M.
    Patel, J.
    Siddiqui, S.
    Luu, M.
    Kearney, B.
    Ramzy, D.
    Chang, D.
    Czer, L.
    Reinsmoen, N.
    Kobashigawa, J.
    AMERICAN JOURNAL OF TRANSPLANTATION, 2015, 15
  • [6] Fatal hyperhemolysis syndrome caused by an anti-human leukocyte antigen antibody
    Cozac, A.
    TRANSFUSION, 2008, 48 (02) : 177A - 177A
  • [7] Prevalence, distribution and amplitude of the complement interference phenomenon in single antigen flow beads assays
    Guidicelli, G.
    Visentin, J.
    Franchini, N.
    Borg, C.
    Merville, P.
    Couzi, L.
    Taupin, J. -L.
    HLA, 2018, 91 (06) : 507 - 513
  • [8] Single human leukocyte antigen flow cytometry beads for accurate identification of human leukocyte antigen antibody specificities
    Pei, R
    Lee, JH
    Shih, NJ
    Chen, M
    Terasaki, PI
    TRANSPLANTATION, 2003, 75 (01) : 43 - 49
  • [9] Anti-Human Leukocyte Antigen Antibody Detection from Terasaki's Humoral Theory to Delisting Strategies in 2024
    San Segundo, David
    Comins-Boo, Alejandra
    Lopez-Hoyos, Marcos
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2025, 26 (02)
  • [10] Neonatal alloimmune thrombocytopenia due to anti-human leukocyte antigen antibody: A case report
    Sasaki, M
    Yagihashi, A
    Kobayashi, D
    Watanabe, N
    Fujikawa, T
    Chiba, S
    Sato, S
    Morishita, K
    Sekimoto, T
    Ikeda, H
    PEDIATRIC HEMATOLOGY AND ONCOLOGY, 2001, 18 (08) : 519 - 524