Dose comparison between screen/film and full-field digital mammography

被引:33
|
作者
Gennaro, Gisella
di Maggio, Cosimo
机构
[1] Univ Padua, Dept Oncol & Surg Sci, I-35128 Padua, Italy
[2] Ist Nazl Fis Nucl, Dept Phys, Padua Unit, I-35131 Padua, Italy
关键词
mammography; digital mammography; dosimetry in mammography; average glandular dose;
D O I
10.1007/s00330-006-0314-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The study purpose was the comparison between doses delivered by a full-field digital mammography system and a screen/film mammography unit, both using the same type of X-ray tube. Exposure parameters and breast thickness were collected for 300 screen/film (GE Senographe DMR) and 296 digital mammograms (GE Senographe 2000D). The entrance surface air kerma (ESAK) was calculated from anode/filter combination, kV(p) and mAs values and breast thickness, by simulating spectra through a program based on a catalogue of experimental X-ray spectra. The average glandular dose (AGD) was also computed. Results showed an overall reduction of average glandular dose by 27% of digital over screen/film mammography. The dose saving was about 15% for thin and thick breasts, while it was between 30% and 40% for intermediate thicknesses. Full-field digital mammography dose reduction is allowed by wider dynamic range and higher efficiency of digital detector, which can be exposed at higher energy spectra than screen/film mammography, and by the separation between acquisition and displaying processes.
引用
收藏
页码:2559 / 2566
页数:8
相关论文
共 50 条
  • [31] Comparison of interpretation times for screening exams between soft copy full-field digital mammography and hard copy screen-film mammography
    Solari, M
    Berns, EA
    Hendrick, RE
    Wolfman, JA
    Willis, W
    Segal, L
    DeLeon, P
    Benjamin, S
    Reddy, D
    Mendelson, E
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 182 (04) : 11 - 11
  • [32] A comparison between film-screen mammography and full-field digital mammography utilizing phase contrast technology in breast cancer screening programs
    Morita, Takako
    Yamada, Maya
    Kano, Akiko
    Nagatsuka, Sumiya
    Honda, Chika
    Endo, Tokiko
    [J]. DIGITAL MAMMOGRAPHY, PROCEEDINGS, 2008, 5116 : 48 - +
  • [33] Comparative study in patients with microcalcifications: full-field digital mammography vs screen-film mammography
    Fischer, U
    Baum, F
    Obenauer, S
    Luftner-Nagel, S
    von Heyden, D
    Vosshenrich, R
    Grabbe, E
    [J]. EUROPEAN RADIOLOGY, 2002, 12 (11) : 2679 - 2683
  • [34] Comparative study in patients with microcalcifications: full-field digital mammography vs screen-film mammography
    U. Fischer
    F. Baum
    S. Obenauer
    S. Luftner-Nagel
    D. von Heyden
    R. Vosshenrich
    E. Grabbe
    [J]. European Radiology, 2002, 12 : 2679 - 2683
  • [35] Detection and characterization of microcalcification with film-screen and full-field digital mammography (FFDM)
    O'Riordan, E
    Bukhanov, K
    Wilson, C
    Sidlofsky, S
    Goldberg, F
    Muradali, D
    [J]. RADIOLOGY, 2000, 217 : 200 - 200
  • [36] Visualization of ductal carcinoma in situ and early invasive carcinoma: Comparison of film-screen mammography and full-field digital mammography
    Feig, SA
    Eskola-Feig, C
    [J]. IWDM 2000: 5TH INTERNATIONAL WORKSHOP ON DIGITAL MAMMOGRAPHY, 2001, : 451 - 460
  • [37] Comparison of full-field digital tomosynthesis with two view conventional film screen mammography in the prediction of lesion malignancy
    Rafferty, EA
    Georgian-Smith, D
    Kopans, DB
    Hall, DA
    Moore, R
    Wu, T
    [J]. RADIOLOGY, 2002, 225 : 268 - 268
  • [38] Comparison of computerized image analyses for digitized screen-film mammograms and full-field digital mammography images
    Li, Hui
    Giger, Maryellen L.
    Yuan, Yading
    Lan, Li
    Suzuki, Kenji
    Jamieson, Andrew
    Yarusso, Laura
    Nishikawa, Robert M.
    Sennett, Charlene
    [J]. DIGITAL MAMOGRAPHY, PROCEEDINGS, 2006, 4046 : 569 - 575
  • [39] Optimization of technique factors for a silicon diode array full-field digital mammography system and comparison to screen-film mammography with matched average glandular dose
    Berns, EA
    Hendrick, RE
    Cutter, GR
    [J]. MEDICAL PHYSICS, 2003, 30 (03) : 334 - 340
  • [40] Optimization of technique factors for a silicon diode array full-field digital mammography system and comparison to screen-film mammography with matched mean glandular dose
    Hendrick, RE
    Berns, EA
    [J]. RADIOLOGY, 2001, 221 : 338 - 339