Influence of Air Pressure on Positive DC Corona Inception Voltage of Stranded Conductors in the Corona cage

被引:0
|
作者
Meng, Xiaobo [1 ,2 ]
Bian, Xingming [1 ,2 ]
Chen, Fenglin [1 ,2 ]
Yang, Yingjian [3 ]
Wang, Liming [1 ,2 ]
Guan, Zhicheng [1 ,2 ]
机构
[1] Tsinghua Univ, Dept Elect Engn, Beiijing 100084, Peoples R China
[2] Tsinghua Univ, Grad Sch Shenzhen, Shenzhen 518055, Peoples R China
[3] State Grid Elect Power Res Inst, Wuhan 430074, Peoples R China
基金
中国国家自然科学基金;
关键词
positive DC corona; inception voltage; air pressure; corona cage; stranded conductors; ONSET VOLTAGE; AVAILABILITY; PERFORMANCE;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The transmission lines pass by the high altitude region with low air pressure, which brings many special problems to the design and operation of the transmission lines. The corona cage is widely used to study the corona performance of conductors for its good economy and maneuverability. A computation model is adopted for evaluating the corona inception voltages of conductors in the corona cage, which is established according to the gas discharge theory. The charge simulation method is introduced to the computation model to calculate the electric field intensity. Then the positive corona inception voltage are calculated according to the positive corona criterion. The influence of air pressure on the corona inception voltage of conductors is analysed systematically. Corona inception voltage decreases as air pressure is lowered. The corona inception voltage may decrease by 9% per 0.01MPa bases on the standard atmospheric pressure, which is mainly due to the enlargement of ionization zone as a result of the increase of effective ionization coefficient.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] Modified Peek formula for calculating positive DC corona inception voltage on polluted insulator
    Amrani, M. L.
    Bouazabia, S.
    Fofana, I
    Meghnefi, F.
    Jabbari, M.
    ELECTRICAL ENGINEERING, 2019, 101 (02) : 489 - 498
  • [22] Research on Environmental Factors of Positive DC Corona Inception Voltage of Overhead transmission lines
    Xu, Hairui
    Wang, Li
    Zhao, Guangli
    Zhang, Wei
    Zhan, Zhu
    Cao, Yaxu
    Jia, Huidong
    2012 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2012,
  • [23] Modified Peek formula for calculating positive DC corona inception voltage on polluted insulator
    M. L. Amrani
    S. Bouazabia
    I. Fofana
    F. Meghnefi
    M. Jabbari
    Electrical Engineering, 2019, 101 : 489 - 498
  • [24] Research on variation of positive DC corona characteristics with air pressure and humidity
    Hui, Jian-Feng
    Guan, Zhi-Cheng
    Wang, Li-Ming
    Ma, Min-Hua
    Li, Qiu-Wei
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2007, 27 (33): : 53 - 58
  • [25] POSITIVE DC CORONA AND SPARK CHARACTERISTICS IN HIGH-PRESSURE AIR
    TAKUMA, T
    CHIBA, M
    ELECTRICAL ENGINEERING IN JAPAN, 1968, 88 (09) : 10 - &
  • [26] The effect of air pressure on the surface electric field intensity characteristics under negative DC corona discharge in a corona cage
    Liu, Hongbo
    Liao, Ruijin
    Zhao, Xuetong
    Lin, Yuandi
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2019, 113 : 244 - 250
  • [27] Influence of air pressure on the detailed characteristics of corona current pulse due to positive corona discharge
    Li, Xuebao
    Cui, Xiang
    Lu, Tiebing
    Li, Dayong
    Chen, Bo
    Fu, Yuke
    PHYSICS OF PLASMAS, 2016, 23 (12)
  • [28] Studies of DC conductor corona in a small corona cage
    Sibilant, GC
    Ijumba, NM
    Britten, AC
    POWERCON 2002: INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY, VOLS 1-4, PROCEEDINGS, 2002, : 2202 - 2207
  • [29] Studies of DC conductor corona in a small corona cage
    Sibilant, GC
    Ijumba, NM
    Britten, AC
    2002 IEEE AFRICON, VOLS 1 AND 2: ELECTROTECHNOLOGICAL SERVICES FOR AFRICA, 2002, : 661 - 664
  • [30] Inception Characteristics of Surge Corona on Line Conductors
    Bousiou, Evanthia I.
    Mikropoulos, Pantelis N.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2023, 30 (04) : 1902 - 1910